Dell Force10 S4820T driver and firmware
Related Dell Force10 S4820T Manual Pages
Download the free PDF manual for Dell Force10 S4820T and other Dell manuals at ManualOwl.com
FTOS Command Reference Guide - Page 31
... found in FTOS. The commands in this
chapter are supported by FTOS on Dell Force10 platforms, as indicated by the
characters that appear under each of the command headings: e E-Series, c
C-Series, s S-Series,
S4810,
S4820T.
This chapter contains these sections:
• Basic File Management Commands • Upgrading the C-Series FPGA
Basic File Management Commands
The commands...
FTOS Command Reference Guide - Page 39
... this copy command as a streamline update.
Enter the keyword synchronize-rpm to copy the new image file to the peer RPM.
Enter the keyword external to designate the target device on the peer RPM as external flash (instead of the default internal flash). Default: Internal Flash
No default behavior
CONFIGURATION
Version 8.4.1.0 Version 7.5.1.0 Version 6.1.1.0
Added IPv6 addressing support for...
FTOS Command Reference Guide - Page 41
... 7.7.1.0, the functions of this command are incorporated into the upgrade command.
For software upgrade details, refer to the FTOS Release Notes.
upgrade (E-Series version) upgrade (C-Series version)
Upgrade the bootflash or boot selector versions. Upgrade the bootflash or boot selector versions.
download alt-full-image
e
Download an alternate FTOS image to the chassis.
File Management | 41
FTOS Command Reference Guide - Page 42
...| support.dell.com
Syntax Command Modes
Command History
Usage Information
Related Commands
download alt-full-image file-url
EXEC Privilege
Version 7.7.1.0 Version 6.5.1.0
Removed form E-Series Introduced
Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.
For software upgrade details, refer to the FTOS Release Notes.
upgrade (E-Series version...
FTOS Command Reference Guide - Page 57
... Application Software Version: 5.3.1.0 Copyright (c) 1999-2004 by Dell Force10 Networks, Inc. Build Time: Sun May 9 00:57:03 PT 2004 Build Path: /local/local0/Release/5-4-1/SW/Bsp/Diag Dell Force10 uptime is 1 days, 3 hours, 16 minutes
System image file is "/home/5.3.1/5.3.1.0/FTOS-ED-RPM1-5.3.1.0.bin"
Chassis Type: E1200 Control Processor: IBM PowerPC 405GP (Rev D) with 268435456 bytes of memory...
FTOS Command Reference Guide - Page 431
... on platforms:
z Bare Metal Provisioning version 2.0 is supported on S4810, S4820T, and z
switches. In a data center network, Bare Metal Provisioning (BMP) automates the configuration and updating of switches, ensuring standard configurations across installed devices. You can configure auto-configuration on a single switch or on multiple switches. BMP allows you to set up a stack with a minimum of...
FTOS Command Reference Guide - Page 1482
www.dell.com | support.dell.com
clock update-calendar
c e s
Set the switch hardware clock based on the software clock.
Syntax
clock update-calendar
Defaults
Not configured.
Command Modes
EXEC Privilege
Command History
Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0
Support added for S-Series Support added for C-Series Introduced for E-Series
Usage Information
Use this command ...
FTOS Command Reference Guide - Page 1529
... switch.
Use this command to minimize the time required for the VLT system to synchronize the default MAC address of the VLT domain on both peer switches when one peer switch reboots.
Version 8.3.19.0 Version 8.3.8.0
Introduced on S4820T Introduced on S4810
unit-id
Explicitly configure the default unit ID of a VLT peer switch.
Syntax Parameters...
Getting Started Guide - Page 7
... and configuration information, refer to the documents listed in Table 1-1.
Table 1-1. S4820T Documents Information Hardware installation and power-up instructions Software configuration
Command line interface
Latest updates
Documentation Installing the S4820T System
FTOS Configuration Guide for the S4820T System FTOS Command Line Reference Guide for the S4820T System FTOS Release Notes for the...
Installing the S4820T System - Page 7
... installation and power-up of the S4820T, for software configuration information, refer to the FTOS Configuration Guide for the S4820T System and for Command Line Interface (CLI) information, refer to the FTOS Command Line Reference Guide for the S4820T System.
NOTE: User port stacking requires Dell Force10 Operating System (FTOS) version 8.3.19.0 NOTE: For information about upgrading the S4820T...
Installing the S4820T System - Page 56
...Force10 TAC Information to Submit When Opening a Support Case
Managing Your Case Downloading Software Updates Technical Documentation Contact Information
Log in to iSupport at http://www.force10networks.com/support/ and select the Service Request tab. • Your name, company name, phone number, and E-mail address • Preferred method of contact • Model number • Software version...
S4820T Configuration Guide - Page 375
... FIP snooping on a switch, other software features are impacted as follows:
• MAC address learning: MAC address learning is not performed on FIP and FCoE frames, which are denied by ACLs dynamically created by FIP snooping on server-facing ports in ENode mode.
• MTU auto-configuration: MTU size is set to mini-jumbo (2500 bytes) when...
S4820T Configuration Guide - Page 403
... RPM E-Series ExaScale Line Card C-Series RPM C-Series Line Card S-Series RPM S-Series Line Card
Boot Code
2.4.2.1 2.3.2.1 2.5.1.9 2.9.1.1 2.7.1.1 2.6.0.2 2.8.2.0 2.8.2.0
The features in this collection are:
• Component Redundancy • Online Insertion and Removal • Hitless Behavior • Graceful Restart • Software Resiliency • Warm Upgrade • Hot-lock Behavior...
S4820T Configuration Guide - Page 417
... all line cards and SFMs. The chassis remains online during the upgrade, but forwarding is interrupted, as shown in Table 20-4, "Control Plane and Data Plane Status during Warm Upgrade," in High Availability.
FTOS supports warm software upgrades under two conditions:
• between consecutive feature releases where only the second digit differs between the running FTOS version number and...
S4820T Configuration Guide - Page 420
www.dell.com | support.dell.com
linecard 4 invalid linecard 5 is not present.
6.5.1.8
Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress
cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area
Upgrade result
All cache boot image ...
S4820T Configuration Guide - Page 517
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
S4820T Configuration Guide - Page 921
...S4820T Stack-Group Assignment Stack Group 1 Stack Group 3
Stack Group 11 SG-13 SG-15
Stack Group 0 Stack Group 2
Stack Group 10
SG-12 SG-14
You can connect the units while they are powered down or up. Stacking ports... an earlier software version, the new unit is put into a card problem state.
• If the unit is running version 8.3.10.x, it is upgraded to use the same FTOS version as the ...
S4820T Configuration Guide - Page 922
www.dell.com | support.dell.com
• if the software version of the new unit predates FTOS 8.3.12.0, the management unit puts the new unit into a card problem state and generates a syslog that identifies the unit, its FTOS version, and its incompatibility for firmware synchronization.
Note: You must enter the stack-unit stack-unit stack-group stack-group command...
S4820T Configuration Guide - Page 1021
... FTOS software elects a primary and secondary VLT peer device.
Use...remote peer.
Priority values are from 1 to 65535. Default: 32768.
3 (Optional) When you create a VLT domain on a switch, system-mac mac-address the FTOS software automatically creates a VLT-system mac-address MAC address used for internal system operations.
Use the system-mac command to explicitly configure the default MAC address...
S4820T Configuration Guide - Page 1024
www.dell.com | support.dell.com
(Optional) Configure Enhanced VLT (eVLT)
Step Task
Command Syntax
6
When you create a VLT domain on a switch, the FTOS system-mac mac-address
software automatically creates a VLT-system MAC
mac-address
address used for internal system operations.
Use the system-mac command to explicitly configure the default MAC address for the domain by entering a new MAC ...