Dell S5000 driver and firmware
Related Dell S5000 Manual Pages
Download the free PDF manual for Dell S5000 and other Dell manuals at ManualOwl.com
Dell Networking Getting Started Guide - Page 5
... documents listed below: Table 1. S5000 Documents
Information
Hardware installation and power-up instructions
Documentation Installing the S5000 Switch
Software configuration
FTOS Configuration Guide for the S5000 Switch
Command line interface
FTOS Command Line Reference Guide for the S5000 Switch
Latest updates
FTOS Release Notes for the S5000 Switch
Introduction
This document provides...
Dell Networking Getting Started Guide - Page 6
...; Screws for rack installation • Two to Four I/O Modules (according to order) • Two Blanks • One RJ-45 to DB-9 female cable • Two AC or DC power cords for AC or DC units (country/region specific) • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information • Software License Agreement...
Dell Networking Getting Started Guide - Page 10
..., 56, and 60) and the four slots for pluggable modules on the S5000 I/ O panel. You can also use the 40GbE ports in 4 × 10GbE mode. The S5000 supports the following possible modules:
• 12-Port Ethernet Module (1G/10G speeds) (slot 0, 1, 2, or 3) • 12-Port Fibre Channel Module (2G/4G/8G speeds) (slot 0) The valid slot numbers...
Dell Networking Getting Started Guide - Page 38
...has two management ports available for system access - a console port and a universal serial bus (USB)-B port. The USB-B port acts the same as the console port. The terminal settings are the same for both access ports. The S5000 supports bare metal provisioning (BMP). For information about how to configure BMP, refer to FTOS Configuration Guide for the S5000 Switch.
Software Configuration Overview...
Dell Networking Getting Started Guide - Page 40
... PC. 2. Install the necessary USB device drivers (you will need an Internet connection). For
assistance, contact Dell Networking Technical Support. 3. Connect the USB-A end of cable into an available USB port on the PC. 4. Connect the USB-B end of cable into the USB-B console port on the S5000. 5. Power on the S5000. 6. Open your terminal software emulation program to access the S5000. 7. Set the...
Dell Networking Getting Started Guide - Page 47
...S5000 to the Network
After you have completed the hardware installation and software configuration for the S5000 system, you can connect to your company network by following your company's cabling requirements.
Figure 25. RJ-45 Network/Management Port... manufacturer's instructions. Table 7. Chassis Physical Design
Parameter Height Width Depth Chassis weight with factory-installed components Rack...
Dell Networking Installation Guide - Page 5
... this guide before you install and power up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing. WARNING: This equipment contains optical transceivers, which comply with the limits of Class 1 laser radiation.
WARNING: When no cable is connected, visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports...
Dell Networking Installation Guide - Page 9
...; Screws for rack installation • Two to Four I/O Modules (according to order) • Two Blanks • One RJ-45 to DB-9 female cable • Two AC or DC power cords for AC or DC units (country/region specific) • Getting Started Guide • Safety and Regulatory Information • Warranty and Support Information • Software License Agreement...
Dell Networking Installation Guide - Page 12
... 0 (for PSU 0) 2. Slot 1 (for Fan Module 0) 3. Slot 2 (for Fan Module 1)
4. Slot 3 (for PSU 1) 5. Grab Handles
Power Supplies
The S5000 supports two hot-swappable PSUs.
NOTE: The PSUs must be installed at the customer site.
The S5000 has SKUs that support the following configurations:
• AC PSU with fan airflow from I/O to Utility • AC-R PSU with...
Dell Networking Installation Guide - Page 49
... Networking products, access to software upgrades and patches, and open and manage your Tech Support cases. Dell Networking iSupport provides integrated, secure access to these services.
Accessing iSupport Services
The URL for iSupport is http://www.force10networks.com/ CSPortal20/Main/Login.aspx . You must have a userid and password to access iSupport services.
1. On the Dell Networking Support...
Dell Networking Installation Guide - Page 50
... Technical Support
How to Contact Dell Networking Tech Support Information to Submit When Opening a Support Case
Managing Your Case Downloading Software Updates Technical Documentation Contact Information
Log in to iSupport at http://www.force10networks.com/ CSPortal20/Main/Login.aspx and select the Service Request tab.
• Your name, company name, phone number, and Email address
•...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch - Page 75
... the current (running) configuration.
show version
Display the current FTOS version information on the system.
S5000
Syntax Command Modes Command History
show version EXEC Privilege
Version 9.0(1.3)
Introduced on the S5000.
Usage Information
Field
Dell Force10 Real Time...
Dell Force10 Operating...
Dell Force10 Application
Fiber Channel Firmware...
Copyright (c)...
Build Time...
Description...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch - Page 76
... software build files loaded on the system Amount of time the system has been up Image file name Switch type (S5000) Control processor information and amount of memory on processor
Amount and type of memory on system Hardware configuration of the system, including the number and type of physical interfaces available
FTOS#show version Dell Force10 Real Time Operating System Software Dell...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch - Page 373
11
Bare Metal Provisioning (BMP)
Bare metal provisioning (BMP) version 2.0 is supported on the S5000 switch. In a data center network, BMP automates the configuration and updating of switches, ensuring standard configurations across the installed devices. You can configure auto-configuration on a single switch or on multiple switches. BMP allows you to set up a stack with a minimum of effort, but...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch - Page 374
.... The startup configuration is then loaded from the local flash on the switch.
Use the reload-type command in BMP 2.0 to toggle between Normal and Jumpstart AutoConfiguration modes. The reload settings for Auto-Configuration mode that you configure are stored in memory and retained for future reboots and BMP software upgrades. You can enter the reload...
FTOS 9.0(1.3) Configuration Guide for the Switch - Page 45
...Connect the USB-A end of cable into an available USB port on the PC. 3. Connect the USB-B end of cable into the USB-B console port on the S5000. 4. Power on the S5000. 5. Install the necessary USB device drivers (you will need an internet connection). For assistance, contact
Dell Networking Technical Support. 6. Open your terminal software emulation program to access the S5000. 7. Set the terminal...
FTOS 9.0(1.3) Configuration Guide for the Switch - Page 364
www.dell.com | support.dell.com
Impact on Other Software Features
When you enable FCoE transit with FIP snooping on a switch, other software features are impacted as follows:
• MAC address learning: MAC address learning is not performed on FIP and FCoE frames, which are denied by ACLs dynamically created by FIP snooping on server-facing ports in ENode mode.
•...
FTOS 9.0(1.3) Configuration Guide for the Switch - Page 487
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Networking implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
FTOS 9.0(1.3) Configuration Guide for the Switch - Page 969
... FTOS software elects a primary and secondary VLT peer device.
Use...remote peer.
Priority values are from 1 to 65535. Default: 32768.
3 (Optional) When you create a VLT domain on a switch, system-mac mac-address the FTOS software automatically creates a VLT-system mac-address MAC address used for internal system operations.
Use the system-mac command to explicitly configure the default MAC address...
FTOS 9.0(1.3) Configuration Guide for the Switch - Page 972
...com | support.dell.com
(Optional) Configure Enhanced VLT (eVLT)
Step Task
Command Syntax
6 When you create a VLT domain on a switch, the FTOS system-mac mac-address
software automatically creates a VLT-system MAC
mac-address
address used for internal system operations.
Use the system-mac command to explicitly configure the default MAC address for the domain by entering a new MAC address in...