Operation Guide - EMP Monitor v4.30 - Page 3
... same segment 11
Procedures for automatic search 11 Procedures for registration 12 Setting the range of addresses to do an automatic search and registration . 13 Procedures for automatic search 13 Procedures for registration 15 Registration by specifying an IP address (Manual registration 17 Registering several projectors to a monitoring group all at once 18
If the...
Operation Guide - EMP Monitor v4.30 - Page 7
...)
Windows Vista SP1 All editions except Starter Edition
• Internet Explorer Ver. 5.0 or later must be installed.
CPU
Pentium MMX 166 MHz or higher (Pentium II 233 MHz
or higher recommended)
Memory capacity 64 MB or more (128 MB or more recommended)
Free hard disk space
50 MB or more
Display
SVGA (800 X 600) or higher resolution, 32...
Operation Guide - EMP Monitor v4.30 - Page 8
... must be installed on the computer to be used for
monitoring and control. • The computer and the projectors must be connected to the network. • If using Windows 2000/Windows NT4.0/Windows XP/Windows
Vista, the computer must be started up in Administrator mode. • Depending on the projector model, a commercially-available serial
TCP/IP conversion adapter and a connection cable are...
Operation Guide - EMP Monitor v4.30 - Page 10
... is located in the same segment as the computer in which EMP Monitor is installed. s "Registering projectors using automatic search (Searching for and registering projectors that are located in the same segment)" p.11
• When registering projectors that are in multiple segments of the network. s "Setting the range of addresses to do an automatic search and registration" p.13
Operation Guide - EMP Monitor v4.30 - Page 22
... temperature level is displayed, you can make improvements to the projector's operating environment before a high internal temperature error or high-temperature warning occur. s p.27
*2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable is connected. - Check that Network Monitoring is set to ON or Standby Mode is set to Network ON in the...
Operation Guide - EMP Monitor v4.30 - Page 24
..., or an incorrect Monitor Password was entered. s p.12, p.15, p.17 Network error (TCP connection error)*2
Network error (ESC/VP.net communication error)*3
Group name: When projectors are registered to a group, the name of the group that the projector belongs to is displayed.
Display name: Shows the display name.
Power: Shows the power on status for the projector.
Power on and normal status...
Operation Guide - EMP Monitor v4.30 - Page 25
....
*2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable is connected. - Check that Network Monitoring is set to ON or Standby Mode is set to Network ON in the projector's configuration menu.
*3 Check that the projector has been correctly connected to the network. *4 You can display Replace lamp at any time preset at Environment...
Operation Guide - EasyMP Monitor v4.40 - Page 7
... update to Windows Vista SP1 to use the Ukrainian version of EasyMP Monitor.
*2 Windows NT4.0 does not support Arabic and Hebrew versions.
Transferring the settings
If you are already using EasyMP or EMP Monitor, you can transfer the projector settings to this version. The settings are stored as a data file (EMP Monitor.dat). Make a copy of the EMP Monitor.dat before you install...
Operation Guide - EasyMP Monitor v4.40 - Page 8
..., and drives" setting in "Advanced settings".
After installing this software, follow the instructions below before starting EasyMP Monitor to transfer the settings.
• If your operating system is Windows 98, Windows Me, Windows 2000, Windows NT4.0, or Windows XP
Overwrite the existing EMP Monitor.dat file with the copy you made. The existing EMP Monitor.dat file is in "C:\Program Files\EPSON...
Operation Guide - EasyMP Monitor v4.40 - Page 9
... installed on the computer to be used for
monitoring and control. • The computer and the projectors must be connected to the network. • If using Windows 2000/Windows NT4.0/Windows XP/Windows
Vista/Windows 7, the computer must be started up in Administrator mode. • Depending on the projector model, a commercially-available serial W TCP/IP conversion adapter and a connection cable...
Operation Guide - EasyMP Monitor v4.40 - Page 23
... level is displayed, you can make improvements to the projector's operating environment before a high internal temperature error or high-temperature warning occur. s p.28
*2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable is connected. - Check that Standby Mode is set to Communication On (or Network On) or Network Monitoring is set to On...
Operation Guide - EasyMP Monitor v4.40 - Page 26
... Error
Shutter error Cooling system error (pump)
*1 When Temperature level display group view is set to On at Environment setup in the Tool menu, an icon indicating the internal temperature of the projector will be displayed on top of the projector icon. The default setting is Off.
*2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable...
Operation Guide - EasyMP Monitor v4.40 - Page 46
... the EasyMP Monitor Ver. x.xx (Ver. x.xx represents the version of the existing software) folder. This folder can be found at "C:\Users\(User Name)\AppData\Local\VirtualStore\Program Files\EPSON Projector" if the default settings were used to install the software. To save or transfer the projector settings, make a copy of the EMP Monitor.dat file before you delete the...
Product Support Bulletin(s) - Page 1
... the PowerLite 61p / 81p / 82c / 821p / 1810 / 260d (Latin America) / 280d (Latin America) models, a serial to TCP/IP conversion adapter is necessary. The function of Auto Update does not work for these models. You need to manually click on refresh to get an updated status of projectors.
Reason: The improved points of version 4.30 are as follows:
Application Version upgraded Improved...
Product Support Bulletin(s) - Page 3
... hard disk space Display
At least 50 MB
SVGA (800×600) or higher resolution, 32 bit or higher display color
Obtaining the Update:
Download epson13055.exe from www.epson.com to get the version 4.30 update for EMP Monitor. The files are extracted and copied to C:\EPSON\epson13055_emp_monitor_430.
This file is a self-extracting archive and will start the installation utility for...
Product Support Bulletin(s) - Page 4
... of usability, and Corresponding to PowerLite 6100i. EMP NS Connection V2.20 supports Windows Vista (Home Basic / Home Premium / Ultimate / Business / Enterprise). Supported 25 languages
Supported 27 languages Addition of new Error Information Supported Video (BNC) Supported 34 languages Additional Input Sources Displays projector's serial number in Menu settings
Page 4 of 4 PSB.2009.06...
Product Support Bulletin(s) - Page 6
... 8300i with the EasyMP.net Option Module installed PowerLite 9300NL
PowerLite 1815p PowerLite 822p PowerLite 6110i PowerLite Cinema 500 PowerLite 61p PowerLite 81p PowerLite 82c
PowerLite 821p
Supported Operating Environment:
Operating System requirement
Minimum CPU requirement Minimum RAM requirement Drive space requirement Display requirements
• Windows 98SE / Me / NT 4.0 SP6 (except...
Product Support Bulletin(s) - Page 7
... support for the Serial ↔ TCP/IP conversion adapter for the PowerLite 61p / 81p
Added support for projectors installed on large scale networks
Addition of timer function, auto search by specifying IP address. Improvement of communication logs sizes
Addition of support for PowerLite 6100i with support for additional monitoring features unique to the PowerLite 6100i
Added support for Windows...
User's Guide - Page 16
... depending on how you've adjusted the optical zoom and other settings.
note
You can download the Projection Distance Calculator program from the Drivers and Downloads section of Epson's web site: http://support.epson.com.
29.5 to 35.4 feet
5.8 to 7 feet
2.8 to 3.4 feet
Also keep these considerations in mind:
■ Place the projector on a sturdy, level surface.
■ Make...
User's Guide - Page 94
...must have a "clean" installation of Windows 98, Windows Me, Windows XP, or Windows 2000. The connection may not work correctly if your system was upgraded from Windows 95.
■ If you're running Windows 98 or Me, you may need to install USB drivers from your Windows CD-ROM. After you install the drivers, restart both the computer and the projector to resynchronize the setup.
94 Solving Problems