HP 9000 rp8440 driver and firmware
Drivers and firmware downloads for this Hewlett-Packard item
Related HP 9000 rp8440 Manual Pages
Download the free PDF manual for HP 9000 rp8440 and other HP manuals at ManualOwl.com
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations - Page 3
...information on nPartitions, refer to the nPartition Administrator's Guide. The appendix Cellbased HP servers and Dynamic nPartitions lists the HP servers that can be configured for nPartitions.
Dynamic ... HP-UX 11i Update 1 and its supporting firmware, and that nPartition must contain a cell in the inactive state. Upon completion of the cell online activation operation, the processor and memory...
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations - Page 9
... functional unless the firmware on the server is upgraded to the firmware that supports the new features. The minimum firmware version for each platform that supports Dynamic nPartitions is shown in the Firmware Matrix.
Dynamic nPartitions, virtual partitions, and Integrity Virtual Machines
HP-UX 11i v3 Virtual Partitions enable dynamic operation through processor and memory migration among vPars...
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations - Page 16
... from the parstatus command indicates that cell 2 has completed its power on reset sequence and is in the "Inactive" state. The demonstration system was not configured for remote invocation of parolrad, so the remaining commands are issued in partition 0.
[par0]# parstatus -C
[Cell]
CPU
Memory
Use
OK/
(GB)
Core On
Hardware Actual
Deconf/ OK/
Cell...
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations - Page 19
... is still completing its power on initialization after being online deactivated from its previous partition. The Use On Next Boot flag was set to false when the ...Install the DynamicNPars product from HP-UX 11i v3 Update 1. Use the vPars processor and memory migration facilities instead of parolrad. Upgrade the system firmware on all cells to at least the minimum version specified in the firmware...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 9
... engineers assigned to support the HP Integrity rx8640 and HP 9000 rp8440 servers.
Publishing History
The following publishing history identifies the editions and release dates of this document. Updates are made to this document on an unscheduled, as needed, basis. The updates will consist of a new release of this document and pertinent online or CD-ROM documentation.
First...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 10
... can access other information on HP server hardware management, Microsoft® Windows® administratuon, and diagnostic support tools at the following Web sites: http://docs.hp.com The main Web site for HP technical documentation is http://docs.hp.com. Server Hardware Information: http://docs.hp.com/hpux/hw/ The http://docs.hp.com/hpux/hw/ Web site...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 11
...manuals, tutorials, FAQs, and other reference material. Web Site for HP Technical Support: http://us-support2.external.hp.com HP IT resource center Web site at http://us-support2.external.hp.com/ provides comprehensive support information for IT professionals on a wide variety of topics, including software, hardware, and networking. Books about HP...this font. Examples: The Control key, the OK button...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 19
... cell board for installing processor modules.
NOTE: Unlike previous HP cell based systems, the server cell board does not require that a termination module be installed at the end of an unused FSB. System firmware is allowed to disable an unused FSB in the CC. This enables both sockets of the unused bus to remain unpopulated.
Table 1-1 Cell Board CPU Module Load...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 39
...to support these devices.
Typical HP 9000 rp8440 Server Power Dissipation and Cooling
Table 2-11 provides calculations for the rp8440 configurations as described in the table. Table 2-11 Typical HP 9000 rp8440 Server Configurations
Cell Board
Qty 4 4 4 2 2 2 1
Memory per Cell Board GBytes 32 16 8 32 16 8 8
PCI Cards (assumes 10W each) Qty 16 16 8 16 8 8 8
DVDs Hard Disk Core
Drives
I/O
Qty...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 40
... will be installed during initial installation or as a later update. Refer to the applicable documentation for such devices to determine the power and air-conditioning that is required to support these devices.
Acoustic Noise Specification
The acoustic noise specification for the servers is 55.6 db (sound pressure level at bystander position). It is appropriate for dedicated computer room...
HP Servers running HP-UX - getsysinfo.sh 9.19 data collection script readme and FAQ - Page 4
.... output of diskinfo -v of all disks (only with -d) Dmesg /var/opt/resmon/log/event.log* files younger than 90 days
-san: Output of fclpdiag or fcddiag or fcocdiag if fibre channel cards exist for this driver
nice grep output from fcmsutil (Fibre Channel Infos)+ tdlist + fcdlist Chassis Error Log Files on newer systems (from...
HP Servers running HP-UX - getsysinfo.sh 9.19 data collection script readme and FAQ - Page 5
... cards connected to LSI SAS HBAs (improved own script) information about Smartarray raid controllers cmclview -v output (if Service Guard cmcld is running) output of sfmconfig -w -q (system fault manager config) /var/opt/sfm/log/event.log system fault manager logs similar to EMS event.log /etc/shutdownlog EVA diskarray infos used by mission critical HP support for...
Generic Site Preparation Guide - Edition 6 - Page 4
... Floor Site...26 Windows...27 Space Requirements...27 Delivery Space Requirements...27 Operational Space Requirements...27 Storage and Powered Off...28 Floor Plan Grid...28 Power Plug Configuration...29 Conversion Factors and Formulas...31 Example of an Installation Schedule...32 Sample Site Inspection Checklist...33 Delivery Survey...35
2 Support and other resources 39
Contacting HP...39 Before...
Generic Site Preparation Guide - Edition 6 - Page 11
... dictate a maximum. In addition to the HP product hardware, you must consider any peripheral equipment that will be installed during initial installation or a later update. See the safety and regulatory labels on equipment or applicable product-specific documentation for such devices to determine the power required to support these devices.
NOTE: Peripheral equipment should have dedicated breakers...
Generic Site Preparation Guide - Edition 6 - Page 27
...: Air Quality (page 16).
Table 1-5 Typical Environments of Customer Installations
Environment
Running at extremes should consider upgrading the facility.
Operating Environment (ambient)1
Temp ºC, dry bulb2 (ºF)
Relative Humidity %: Noncondensing
Dew-point (max) 3
Rate of Chg ºC/hr, max
(ºF/hr, max)
Controlled Computer 18 to 27
20 to 80
17
Room 4
(65 to...
BCS Global Limited Warranty and Technical Support - Page 6
...routine diagnostic procedures, installing additional software updates or patches, removing third-party options, and/or substituting options.
• Make periodic backup copies of your files, data, or programs stored on your hard drive or other storage devices as a precaution against possible failures, alteration, or loss. Before returning any HP Hardware Product for warranty support, back up your...
BCS Global Limited Warranty and Technical Support - Page 8
..., troubleshooting assistance, and access
to the patch database, firmware/software update packages, and documentation. For more information, see http://www.hp.com/support or http://www.itrc.hp.com. • Technical phone support provides hardware warranty troubleshooting and issue resolution. For more information see http://www.hp.com/support. • Warranty information in the tables that follow...
BCS Global Limited Warranty and Technical Support - Page 11
...hours
Next business day response
Notes and Exceptions
rx4640, rx5670 3 year
Remote monitoring & email notification of errors & events
CSR6: Available on some parts. Go to www.hp.com/go/ csrparts for component CSR details.
Firmware upgrade & pre-upgrade tasks
Onsite Warranty Service for service events not remedied either remotely or through CSR6
Normal business hours
Next business day response...
Errata for HP 9000 Servers with PA-8900 Processors and sx2000 Chipset, Second Edition: Additional HP-UX 11i v1 (B.11.11) patches - Page 2
... 2007 before updating your server with the latest system firmware. For more information, please see the release notes for this system firmware.
HP-UX 11i v1 (B.11.11) patches for HP 9000 servers with PA-8900 processors and sx2000 chipset
The December 2006 version of the Partition Manager product includes support for the HP-UX Peripheral Device Tool (pdweb) to display details about...
Verify Firmware Version of sx2000 SEU During Installation, First Edition - HP 9000 rp8440 server, SEU and HP Integrity rx8640 se - Page 2
...refer to the applicable rp8440/rp7440 and SEU firmware release notes for download and update instructions.
Note that the SEU contains the following firmware and programmable hardware entities which must be verified during installation:
PROGRAMMABLE HARDWARE: System Backplane: GPM System Backplane: EMMUX IO Backplane: IO_LPM Core IO: CIO
FIRMWARE: Core IO: MP Core IO: ED
For further information...