Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 77
... current system ROM may not support this SCSI controller. You may need to update your system ROM. Event identifier: cpqstmsg.dll - 1344 (Hex)0x84350540 (Service Event) Log Severity: Warning (2) Log Message: A version mismatch has been detected with the SCSI device monitor driver (CPQSDM.SYS). The current driver version is %1. Cause: You may not have rebooted after a Storage Agents upgrade. Always...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 126
... the Remote Insight Board device driver (CPQSM2.SYS) to be installed. Install the driver from the latest Software Support for Windows. If you do not have a Remote Insight Board in this system, disable the Remote Insight Agent via the Management Agents Control Panel. Event identifier: cpqsvmsg.dll - 3351 (Hex)0x84350d17 (Service Event) Log Severity: Warning (2) Log Message: The shared memory...
HP USB Floppy Drive Key Installation Instructions - Page 2
...how to disconnect the drive key.
Downloading user documentation and drivers
DOWNLOAD INFORMATION To download the latest user documentation and drivers:
1. Go to www.hp.com.
2. Click Support and Troubleshooting Information from the left menu bar.
3. Type the product name in the product field and press Enter.
4. Click Manuals from the Resources section or Download Drivers and Software from the Tasks...
ProLiant Essentials Foundation Pack Installation Guide - Page 1
...8226; Download the latest individual software components from the Software and Driver download pages available from www.hp.com/support
• Use HP SIM and Version Control to automatically download the latest versions of ProLiant software, identify servers running out-of-date software, and deploy updates to groups of systems running Windows or Linux.
• Download or buy a ProLiant Essentials...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant - Page 4
.... Use the part number and the date on the title page to determine which version you are using. The contents of this guide are updated frequently and newer versions are placed on the HP website. Download and open the updated file to use the current HP BladeSystem Management Packs for Microsoft® System Center Essentials Troubleshooting Assistant.
Overview 4
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant - Page 13
...® Windows® operating system version and patch levels o The HP BladeSystem Management Packs for Microsoft® System Center Essentials version
installed o The versions of Insight Management Agents as associated plug-in tools (such as Version Control
Agents and Insight Diagnostics) o HP server type and models o HP server serial number o Screen prints of any error messages received...
Error Prevention Guide - Page 5
... system software with the version control feature of Insight Manager 7. Using this feature, you can easily determine whether version updates are available for server BIOS, drivers, and agents.
Server Design
Design the server setup to minimize the impact of downtime. For example, on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide - Page 68
...® Windows® operating system version and patch levels o The HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 version
installed o The versions of Insight Management Agents as associated plug-in tools (such as Version Control
Agents and Insight Diagnostics) o HP server type and models o HP server serial number o Screen prints of any error messages received...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 8
... Driver Update (DU) for Solaris (x86) 10" on the "Software and Drivers" page.
○ Broadcom NetXtreme II driver-If you are using network interface card (NIC) models
NC370x, NC371x, NC373x, NC374x, or NC380x, the bnx driver is required. This driver is applied post-installation.
• CD or DVD drive-A CD-ROM or DVD-ROM drive is required to load the Solaris software. A
Universal Serial Bus (USB...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 9
...or HP support personnel.
To install Solaris on a ProLiant server: 1. Ensure you have met all the requirements for installation and have all the necessary tools
available for installation, including a Smart Array Driver Update (DU) diskette or CD, if necessary. For more information, see "Prerequisites." 2. Apply system ROM and other firmware updates, as necessary. 3. If installing to disks attached...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 11
...recovery from various errors or failures because it contains a comprehensive set of tools and utilities. Other important components of the miniroot include:
• Drivers-The miniroot must contain all device drivers that are required for installation, or those
drivers must be loaded before installation begins. For ProLiant servers, these drivers usually include the Smart Array driver and network...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 13
... from the controller, the driver must be installed on the system during deployment. For more information, see "Miniroot" and "JumpStart."
NOTE: On the "Software and Drivers" load page, the cpqary3 driver is listed as "HP Driver Update (DU) for Solaris (x86) 10."
• Broadcom NetXtreme II driver-Current ProLiant generations use newer Broadcom NIC chipsets
for embedded NICs. The driver for these...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 14
... virtual media
Virtual media support, part of the iLO Advanced feature set, provides administrators with a virtual diskette drive, USB key drive, and a virtual CD/DVD drive that connect through the network to the managed server, as if they were physically connected to each other.
Using a custom-built bootable ISO, a Solaris installation can be booted remotely with virtual media, without...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 17
... not a part of the Solaris distribution, such as the Smart Array driver, can also be delivered through NFS. Setting up an NFS installation image offers flexibility in the variety of installation configurations that a single image can support.
• Flash Archive-A portable, flexible image of a reference installation. A flash archive enables
you to clone a master system to any number of...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 26
... guide, requires X
Windows. For information about configuring the DHCP server from the command line, see System Administration Guide: IP Services at http://docs.sun.com/app/docs/doc/816-4554.
• Install server is a DHCP server-The following instructions assume that the install server is also
the DHCP server, and that the media has already been copied to disk...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 48
... • HP Smart Array Controller Driver for Solaris 10 User Guide, at
ftp://ftp.compaq.com/pub/softlib2/ software1/pubswwindows/p308167783/v40878/HP_Smart_Array_Controller_Driver_User_Guide.pdf
• HP ROM-Based Setup Utility User Guide, at http://h20000.www2.hp.com/bc/docs/support/
SupportManual/c00191707/c00191707.pdf
Free Software Foundation documentation
• GNU GRUB Manual 0.97...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 54
... shell prompt, 43 SNMP master agent, 40 software delivery methods, 17 Solaris installation components, 10 deploying ProLiant servers, 12
general process flow, 10 network deployment infrastructure, 11 overview, 10 Solaris media packages, 11 system becomes unresponsive using remote console, 45 system does not boot to GRUB, 44
T technical support, 48 TFTP server, 12 troubleshooting
basic techniques...
BCS Global Limited Warranty and Technical Support, Third Edition - Page 6
... Product in
accordance with the instructions furnished. • Verify configurations, load most recent firmware, install software patches, run HP diagnostics
and utilities, and implement temporary procedures or workarounds provided by HP while HP works on permanent solutions. • Allow HP to keep resident on your systems or sites certain system and network diagnosis and maintenance tools to...
BCS Global Limited Warranty and Technical Support, Third Edition - Page 8
..., troubleshooting assistance, and access
to the patch database, firmware/software update packages, and documentation. For more information, see http://www.hp.com/support or http://www.itrc.hp.com. • Technical phone support provides hardware warranty troubleshooting and issue resolution. For more information see http://www.hp.com/support. • Warranty information in the tables that follow...
HP ProLiant DL785 G5 and G6 Servers - Maintenance and Service Guide, Seventh Edition - Page 55
... with other software maintenance, deployment, and operating system tools • Automatically checks for hardware, firmware, and operating system dependencies, and
installs only the correct ROM upgrades required by each target server To download the tool and for more information, refer to the HP website (http://www.hp.com/support).
Integrated Management Log
The IML records hundreds of events...