Product Specification - Page 2
... Section 9.2 MTBF - Added Appendix G Installation Guidelines - Added Processor Stepping Mismatching on Table 2 - Updated Boot Option BIOS Setup Menu (Table 34 and Figure 36) - Updated Table 4 Memory Running Frequency - Updated Table 12 Intel® SAS Entry RAID Module AXX4SASMOD Storage
Mode - Updated Table 47 and Table 48, CPU 1 and CPU2 power connectors pin-out - Updated Table 84 POST Codes and...
Product Specification - Page 36
... interface and Thermal Design Power (TDP) up to 130 W.
The server boards do not support previous generations of the Intel® Xeon® Processors.
For a complete updated list of supported processors, see: http://support.intel.com/support/motherboards/server/S5520HC/. On the Support tab, look for "Compatibility" and then "Supported Processor List".
3.2.1
Processor Population Rules
You must...
Product Specification - Page 38
... the processor. - Displays "8180: Processor 0x microcode update not found" message
in the Error Manager or on the screen. - The system continues to boot in a degraded state, regardless of the
setting of POST Error Pause in Setup.
3.2.3
Intel® Hyper-Threading Technology (Intel® HT)
If the installed processor supports the Intel® Hyper-Threading Technology, the BIOS Setup provides...
Product Specification - Page 53
...1000 Gigabit Ethernet MAC with System Defense System Management Bus (SMBus) Specification, Version 2.0, with additional support for
I2C devices Low-Pin Count (LPC) interface support Firmware Hub (FWH) interface support Serial Peripheral Interface (SPI) support
3.4.1
Serial ATA Support
The ICH10R has an integrated Serial ATA (SATA) controller that supports independent...
Product Specification - Page 54
... OS support
AHCI driver or OS embedded Broad OS support ESRTII Driver Microsoft Windows* and selected Linux* Versions only
RAID Management
Software N/A
N/A
N/A
Intel® RAID Web Console 2
RAID Software User's Guide
N/A
N/A
N/A
Intel® RAID Software User's Guide
Compatible Backplane
AXX6DRV3GR AXX4DRV3GR
* Select in BIOS Setup: "SATA Mode" Option on Advanced | Mass Storage Controller...
Product Specification - Page 60
...SATA drives via expander backplanes
SW RAID 0/1/10 standard
SW RAID 5 with optional AXXRAKSW5
ESRTII Driver
Microsoft Windows* and selected Linux* Versions only
Intel® RAID Web Console 2
Intel® RAID Software User's Guide
*Select in BIOS Setup: "Configure Intel® SAS Entry RAID" Option on Advanced | Mass Storage Controller
Configuration Screen
3.6.1.1
IT/IR RAID Mode
Supports...
Product Specification - Page 67
... an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state.
The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM. You use this option to clear security settings for a newly initialized system or to clear a system...
Product Specification - Page 75
...firmware. Figure 27 provides an illustration of the Server Management Bus (SMBUS) architecture as used on these server boards.
4.1 Feature Support
4.1.1
• • •
IPMI 2.0 Features
Baseboard management controller (BMC).
IPMI Watchdog timer.
Messaging support, including command bridging and user/session support.
Chassis device functionality, including power/reset control and BIOS...
Product Specification - Page 77
...174; Remote Management Module 3 (Intel® RMM3) card. Without the Intel® RMM3, the advanced
features are dormant.
4.2.1.1
Intel® Remote Management Module 3 (Intel® RMM3)
The Intel® RMM3 provides the BMC with an additional dedicated network interface. The dedicated interface consumes its own LAN channel. Additionally, the Intel® RMM3 provides
additional flash storage...
Product Specification - Page 78
... to allow system administrators or users to mount a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears as a local device to the server, allowing system administrators or users to boot the server or install software (including operating systems), copy files, update the BIOS, and so forth, or boot the server from...
Product Specification - Page 79
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Platform Management
• You can mount either IDE (CD-ROM, floppy) or USB devices as a remote device to the server.
• It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. For more information, refer to the...
Product Specification - Page 82
... telling it which fan profile the platform is set up for: Acoustics Mode or Performance Mode. The BIOS uses the parameters retrieved from the thermal sensor data records (SDR), fan profile setting from BIOS Setup, and altitude setting from the BIOS Setup to configure the system for memory throttling and fan speed control. If the
68
Revision 1.8
Intel order number E39529-013
Product Specification - Page 84
... to control those factors.
The BMC supports Intel® Intelligent Power Node Manager specification version 1.5. Additionally, the platform must have an Intel® Intelligent Power Node Manager capable Manageability Engine (ME) firmware installed.
The BMC firmware implements power-management features based on the Power Management Bus (PMBus) 1.1 Specification.
Note: Intelligent Power Node...
Product Specification - Page 94
BIOS Setup Utility
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Table 23. Setup Utility - Processor Configuration Screen Fields
Setup Item Processor ID Processor Frequency Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor 1 Version
Options
Processor 2 Version
Current Intel® QPI Link Speed
Intel® QPI Link Frequency
Intel® Turbo Boost Technolgy...
Product Specification - Page 100
BIOS Setup Utility
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Table 26. Setup Utility - Mass Storage Controller Configuration Screen Fields
Setup Item Intel® Entry SAS RAID Module Configure Intel® Entry SAS RAID Module
Onboard SATA Controller SATA Mode
SATA Port 0
SATA Port 1
SATA Port 2
SATA Port 3
SATA Port 4
SATA Port 5
Options Enabled Disabled IT/IR RAID Intel...
Product Specification - Page 110
BIOS Setup Utility
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Setup Item O/S Boot Watchdog Timer
O/S Boot Watchdog Timer Policy
O/S Boot Watchdog Timer Timeout
Plug & Play BMC Detection ACPI 1.0 Support
Console Redirection
System Information
Options Enabled Disabled
Power Off Reset
5 minutes 10 minutes 15 minutes 20 minutes Enabled Disabled
Enabled Disabled
Help Text
If ...
Product Specification - Page 112
...Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision SDR Revision UUID
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Server Management
Figure 41. Setup Utility - Server Management System Information Screen Display
Table 34. Setup Utility - Server Management System Information Fields
Setup Item Board Part Number Board Serial Number System Part Number...
Product Specification - Page 159
... server board no longer supports the Rolling BIOS (two BIOS banks). It implements the BIOS Recovery mechanism instead.
• When performing a normal BIOS update procedure, you must set the BIOS Recovery jumper (J1E5) to its default position (pins 1-2).
• Locate the device that generates System Event Log (SEL) PCI device event: the SEL PCI device event may not specify which PCI device in...
Product Specification - Page 178
... Environment (DXE) Core (not accompanied by a beep code)
0xE4
Entered EFI driver execution phase (DXE)
0xE5
Started dispatching drivers
0xE6
Started connecting drivers
DXE Drivers (not accompanied by a beep code)
0xE7
Waiting for user input
0xE8
Checking password
0xE9
Entering the BIOS Setup
0xEA
Flash Update
0xEE
Calling Int 19. One beep unless silent boot is enabled.
0xEF...
Product Specification - Page 184
... Solaris* No driver required under Sun Solaris*
2. Sun Solaris* 10 U5 (05/08) hangs during early boot when EHCI-2 is enabled
Description Guideline
Sun Solaris* 10 U5 may hang during early boot in the Intel® Server Board S5520HC or S5500HCV when USB 2.0 is Enabled
Disable "USB 2.0 Controller" option in BIOS Setup Menu, or follow the instructions listed at...