HP StorageWorks 16-EL - SAN Switch driver and firmware

Drivers and firmware downloads for this Hewlett-Packard item

We have a direct link to download HP StorageWorks 16-EL drivers, firmware and other resources directly from the HP site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

StorageWorks 16-EL driver download page on the HP site

Related HP StorageWorks 16-EL Manual Pages

Download the free PDF manual for HP StorageWorks 16-EL and other HP manuals at ManualOwl.com

ISS Technology Update Volume 8, Number 5 - Page 5

... Networking Software Current Softpaq sp43831.exe All firmware upgrades and complete Softpaqs can be downloaded from http:www.hp.com/go/ProLiantNICs. Select ―Support and Documents‖ and enter the product name/number. Additional resources For additional information on the topics discussed in this article, visit these resources: HP iSCSI resources HP network adapters URL http:www.hp...
HP StorageWorks Secure Fabric OS for V3.1.x/4.1.x Firmware Release Notes (AV-RUK8A-TE, June 2003) - Page 6

... functions that support automated installation of digital certificates onto multiple switches. Installation of digital certificates is one part of the process for upgrading switches to support Secure Fabric operations. Installation The pki_nt.zip file should be downloaded from the HP website at http://www.hp.com/country/us/eng/prodserv/storage.html. Unzipping it installs the pkicert executable...
HP StorageWorks Web Tools V3.1.x/4.1.x User Guide (AA-RS25C-TE, June 2003) - Page 4

... 61 About Switch Management 62 Switch Explorer for the Core Switch 2/64 62 Switch Explorer for SAN Switch 2/32 63 Switch Information Field Descriptions 64 About the Switch Status Button 65 Switch Status Example 65 Using the Switch Status Button 66 About the Switch Events Button 67 Switch Events Example 67 Switch Events Field Descriptions 67 4 Web Tools Version 3.1.x/4.1.x User Guide
HP StorageWorks Web Tools V3.1.x/4.1.x User Guide (AA-RS25C-TE, June 2003) - Page 269

... Switch 2/64 with single CP-loss of network connectivity due to reboot is approximately 4 minutes if diagpost is disabled and up to 16 minutes if diagpost is enabled. ■ SAN Switch 2/32-loss of network connectivity due to reboot is approximately 4 minutes if diagpost is disabled and 8 minutes if diagpost is enabled. Web Tools Version 3.1.x/4.1.x User Guide 269
HP StorageWorks Web Tools V3.1.x/4.1.x User Guide (AA-RS25C-TE, June 2003) - Page 284

... "partitions," into which firmware can be downloaded in the StorageWorks Core switch. Flash Programmable NVRAM memory that maintains its contents. FLOGI Fabric Login. The process by which an N_Port determines whether a fabric is present, and if so, exchanges service parameters with it. See also PLOGI. Frame The Fibre Channel structure used to transmit data between ports. Consists of...
HP StorageWorks Zoning V3.1.x/4.1.x User Guide (AA-RS26C-TE, June 2003) - Page 84

... "partitions," into which firmware can be downloaded in the StorageWorks Core switch. Flash Programmable NVRAM memory that maintains its contents. FLOGI Fabric Login. The process by which an N_Port determines whether a fabric is present, and if so, exchanges service parameters with it. See also PLOGI. Frame The Fibre Channel structure used to transmit data between ports. Consists of...
SAN Switch 2/16 version 3.1.x - Installation Guide - Page 86

... password for the user ID specified. If only configupload is entered, the system will prompt you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 86 SAN Switch 2/16 Version 3.1.x Installation Guide
SAN Switch 2/16 version 3.1.x - Installation Guide - Page 88

...or Restoring the Switch Firmware The SAN Switch 2/16 ships with preloaded firmware. In most cases, there is no need to update the firmware on the new switch. The firmware version can be determined by using: ■ The version command via Telnet ■ The Switch Management Application page in Web Tools Use these steps to upgrade or restore the switch firmware. 1. Verify that the RSHD service (on...
SAN Switch 2/16 version 3.1.x - Installation Guide - Page 89

Backing Up the Configuration and Upgrading Firmware Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. The website contains the required loaders and instructions for downloading the firmware to a switch. SAN Switch 2/16 Version 3.1.x Installation Guide 89
Fabric OS V3.1.1C Release Notes - Page 3

...; Purpose of release, page 3 ■ Supported switches, page 4 ■ Supported configurations, page 4 ■ Related documentation, page 4 ■ Accessing software, page 6 ■ Obtaining software license keys, page 7 ■ Removing software licenses, page 7 ■ HP recommendations for redundant fabrics and drivers, page 8 ■ Firmware compatibility, page 9 ■ Java Runtime...
Fabric OS V3.1.1C Release Notes - Page 6

... information. The switch overview page displays. 7. Locate the product information section. 8. Click technical documents. 9. Select the applicable documents. Accessing software HP StorageWorks SAN Switch 2/8 and 2/16 ship with the latest version of firmware installed. The firmware is available on the HP web site at: http://www.hp.com/country/us/eng/prodserv/storage.html Note: HP has made every...
Fabric OS V3.1.1C Release Notes - Page 9

....1.1c firmware be updated to version 3.1.1c together, so all supported switches operate with the same firmware version. Refer to the HP StorageWorks SAN Design Reference Guide for information on supported versions of firmware. This document is available at: http://h18000.www1.hp.com/products/storageworks/san/documentation.html Obtaining firmware and upgrade instructions Version 3.1.1c firmware is...
Fabric OS V3.1.1C Release Notes - Page 10

... systems is located on the HP StorageWorks SAN Switch Software v3.1.1x CD. To access the Windows Java Plug-in: 1. Locate the FIRMWARE files folder on the CD. 2. In the FIRMWARE files folder, locate and double-click on the following file: j2re-1_3_1_04-windows-i586-i.exe This file is a self-extracting executable file that will install your Java Runtime Environment...
Fabric OS V3.1.1C Release Notes - Page 12

..., refer to HP StorageWorks Extended Fabric Version 3.1.x/4.1.x User Guide. HP StorageWorks Fabric OS Procedures Version 3.1.x/4.1.x User Guide Please add the following note after Step 7 on page 81: Note: When the v4.1.x firmware is unzipped, it creates a folder and a set of firmware files. Use the following directory and file name when downloading this firmware to the switch: /v4.1.x/release...
SAN switch 2/16 v3.1.x installation guide - Page 86

... password for the user ID specified. If only configupload is entered, the system will prompt you for each parameter, as follows: Example: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 86 SAN Switch 2/16 Version 3.1.x Installation Guide
SAN switch 2/16 v3.1.x installation guide - Page 89

Backing Up the Configuration and Upgrading Firmware Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. The website contains the required loaders and instructions for downloading the firmware to a switch. SAN Switch 2/16 Version 3.1.x Installation Guide 89
Fabric OS V3.1.1X Release Notes - Page 3

..., page 4 ■ Purpose of Release, page 4 ■ Supported Configurations, page 4 ■ Related Documentation, page 4 ■ Software CD, page 6 ■ Obtaining Software License Keys, page 7 ■ Removing Software Licenses, page 8 ■ HP Recommendations for Redundant Fabrics and Drivers, page 8 ■ Firmware Compatibility, page 8 ■ Java Runtime Environment, page 9 ■...
Fabric OS V3.1.1X Release Notes - Page 6

... documents. Software CD HP StorageWorks SAN Switch 2/8 and 2/16 ship with the latest version of firmware installed. A copy of the latest version of the firmware, v3.1.1x, is also contained on the HP StorageWorks SAN Switch Software V3.1 CD, part number AG-RR86D-BE. The firmware is also available on the HP website at: http://www.hp.com/country/us/eng/prodserv/storage.html Note: HP has made...
Fabric OS V3.1.1X Release Notes - Page 9

...firmware be updated to version 3.1.1x together, so all supported switches operate with the same firmware version. Refer to the HP StorageWorks SAN Design Reference Guide, part number AA-RMPNH-TE, for information on supported versions of firmware. This document is available at: http://h18006.www1.hp.com/products/storageworks/san/documentation.html Obtaining Firmware and Upgrade Instructions Version...
Fabric OS V3.1.1X Release Notes - Page 11

... 81: Note: When the v4.1.0 firmware is unzipped, it creates a folder and a set of firmware files. Use the following directory and file name when downloading this firmware to the switch: /v4.1.0/release.plist. For the User prompt, enter a User ID that has an account on the FTP server. HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide In the "Description v4.1.x" section...
Get Help Online

Get immediate support for your HP StorageWorks 16-EL questions from HelpOwl.com.

Recent HP StorageWorks 16-EL-related questions:

HP Manuals

Find free HP StorageWorks 16-EL - SAN Switch manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the HP corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.