S2600GZ/GL - Page 50

... MB to 32 GB. • Support USB Mass Storage Class requirements for Boot capability. 3.3.3 Embedded Serial ATA (SATA)/Serial Attached SCSI (SAS)/RAID Support The Intel® C602 chipset provides storage support from two integrated controllers: AHCI and SCU. By default the server board will support up to 6 SATA ports: Two single 6Gb/sec SATA ports routed from the AHCI controller to the two white...
S2600GZ/GL - Page 51

... Software Stack  Software RAID with system providing memory and CPU utilization  Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key  Maximum drive support = 8  Open Source Compliance = Binary Driver...
S2600GZ/GL - Page 52

...Storage Manager for Windows*  MDRAID supported in Linux (Does not require a driver) Note: No boot drive support to targets attached through SAS expander card. 1) See latest product errata list for support status. Product Errata are documented in the Intel® Server Board S2600GZ/GL, Intel® Server System R1000GZ/GL, Intel® Server System R2000GZ/GL Monthly Specification Update...
S2600GZ/GL - Page 65

...which the server board is integrated and any additional system level components and options that may be installed. 6.1.1 IPMI 2.0 Features  Baseboard management controller (BMC)  IPMI Watchdog timer  Messaging support, including command bridging and user/session support  Chassis device functionality, including power/reset control and BIOS boot flags support ...
S2600GZ/GL - Page 89

Intel® Server Board S2600GZ/GL TPS Advanced Management Feature Support (RMM4) device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device. The following capabilities are supported:  The operation of remotely mounted devices is...
S2600GZ/GL - Page 102

... the BIOS Recovery Jumper on the server board and move the jumper block from pins 1-2 (default) to pins 2-3 (recovery setting). 4. Insert the recovery media into a USB port. 5. Power ON the system. 6. The system will automatically boot into the embedded EFI Shell. 7. The STARTUP.NSH file automatically executes and initiates the flash update. When complete, the IFlash utility will display a message...
S2600GZ/GL - Page 241

...; Intel® Server System R2000GZ/GL Technical Product Specification  Intel® Deployment Assistant (IDA) 5.2 Users Guide  One Boot Flash Update Installation and Users GuideIntel® Active System Control Console User GuideIntel® Intelligent Power Node Manager White Paper  Intel® System Management Software Installation Guide Revision...
R1000GZ and R1000GL - Page 48

...on the server board is an Intel® C602 chipset that provides embedded storage support via two integrated controllers: AHCI and SCU. The server board (with no additional storage options installed) will support up to six SATA ports: • Two 6 Gb/sec SATA ports routed from the AHCI controller to two white 7-pin SATA ports labeled "SATA-0" and "SATA-1" on the server board. Embedded RAID levels...
R1000GZ and R1000GL - Page 49

... providing memory and CPU utilization • Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key • Maximum drive support = 8 o NOTE: ESRT2 has no SAS Expander Support • Open Source Compliance = Binary Driver (includes...
R1000GZ and R1000GL - Page 61

... H3 are only supported when CPU-2 is installed. • The CPU-2 heat sink must be installed at all times, with or without a processor installed. • PCI Riser Slot-2 is only functional when two processors are installed. • The Mini-SAS connector labeled "SCU_01(4-7)" on the server board is only functional when an appropriate Intel® RAID C600 Upgrade Key is installed. • Many...
R2000GZ and R2000GL - Page 46

....06.0002 or later  BMC Firmware 01.17.4207 or later  FRUSDR 1.09 or later Intel highly recommends that the latest available system software be installed. The latest system update package can be downloaded from the following Intel web site: http://downloadcenter.intel.com • The following BIOS Setup Utility Options must be set:  MMIO over 4GB = Enabled...
R2000GZ and R2000GL - Page 57

... board is an Intel® C602 chipset that provides embedded storage support via two integrated controllers: AHCI and SCU. The standard server board (with no additional storage options installed) will support up to six SATA ports: • Two single 6 Gb/sec SATA ports routed from the AHCI controller to two white 7-pin SATA ports labeled "SATA-0" and "SATA-1" on the server board. Embedded RAID...
R2000GZ and R2000GL - Page 58

... providing memory and CPU utilization • Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key • Maximum drive support = 8 o NOTE: ESRT2 has no SAS Expander Support • Open Source Compliance = Binary Driver (includes...
R2000GZ and R2000GL - Page 77

... or without a processor installed • DIMM slots E1 thru H3 are only supported when CPU-2 is installed. • PCI Riser Slot-2 is only functional when two CPUs are installed. • The Mini-SAS connector labeled "SCU_1(4-7)" on the server board is only functional when an appropriate Intel® RAID C600 Upgrade Key is installed. • Many integrated on-board SAS and RAID options are...
Monthly Specification Update - Page 3

...Upgrade Key replacement Issue 9 17. Intel® LAN driver installation failure on Windows* 7 9 18. On-board VGA cannot be set to the highest resolution (1920x1080 and higher).. 10 19. Hard drive locate LED may not instantly respond to the locate command if backplane is connected through SAS expander to a RAID controller 10 20. Integrated BMC Web Console - Sensor Readings Page - Memory...
Monthly Specification Update - Page 7

... under ESRT2 mode of the SCU controller 15. Fix Hard drives connected through SAS expander can't be detected in legacy mode 16. Fixed Intel® RAID C600 Upgrade Key replacement Issue 17. Fixed Intel® LAN driver installation failure on Windows* 7 18. Fixed On-board VGA cannot be set to the highest resolution (1920x1080 and higher) 19. Fixed Hard drive locate LED may not instantly...
Monthly Specification Update - Page 9

... install UEFI Windows Server 2008* R2 SP1 on Intel® C600 Series Chipset based Server Boards with mentioned configuration. This issue was fixed in BIOS 01.03.0002 and later version. None. 3. UEFI Operating System installation is not supported on ESRT2 mode Problem UEFI OS installation of Microsoft Windows*, Red Hat* Linux or SUSE* Linux may fail on AHCI or SCU controller...
Monthly Specification Update - Page 11

... Intel ® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is installed to enable SAS support capablity under ESRT2 mode while SAS drivers are used, the system may halt at the boot stage. Implication User may see a system halt with no RAID keys installed with SAS drivers used and ESRT2 enabled. User should use SATA drives only if no RAID...
Monthly Specification Update - Page 14

... be fixed in a future BIOS release. None. 16. Intel® RAID C600 Upgrade Key replacement Issue Problem Implication Status Workaround With Manageability Engine (ME) Firmware 02.01.05.069, the server may detect the incorrect Storage Control Unit (SCU) Redundant Array of Inexpensive/Independent Disks (RAID) information after installing or replacing the RAID upgrade key. The board or system may...
User Guide - Page 54

Getting Started with Intel®RMM4 Operation Intel®Remote Management Module 4 and Integrated BMC Web Console User Guide 5. Getting Started with Intel®RMM4 Operation The Intel® RMM4 module features remote KVM access and control through LAN or Internet. The Intel® Integrated BMC Web Console is part of the standard BMC firmware / Server Management Software. The Integrated BMC ...
Get Help Online

Get immediate support for your Intel R1000GZ questions from HelpOwl.com.

Recent Intel R1000GZ-related questions:

Intel Manuals

Find free Intel R1000GZ manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.