Intel R1000JP driver and firmware

Drivers and firmware downloads for this Intel item

We have a direct link to download Intel R1000JP drivers, firmware and other resources directly from the Intel site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

R1000JP driver download page on the Intel site

Related Intel R1000JP Manual Pages

Download the free PDF manual for Intel R1000JP and other Intel manuals at ManualOwl.com

System Service Guide - Page 5

... for installing or replacing components such as the fan, power supply, and front panel board, among other components. Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes information for navigating through the BIOS Setup screens, performing a BIOS update, and resetting the password or BIOS defaults...
System Service Guide - Page 6

... For software to manage your Intel® Server System For system firmware updates and onboard device drivers Product Safety and Regulatory document Use this Document or Software Intel® Server System R1000JP Family Technical Product Specification See the section on the web page titled, "Architecture/Specifications". Intel® Server System R1000JP Family Quick Installation User's Guide See...
System Service Guide - Page 36

... 2: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing the following: 1. Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. 24 Intel® Server System R1000JP Family Service Guide
System Service Guide - Page 48

... Upgrade Key The server board supports various Intel® Storage Upgrade Keys for different storage configuration. Below is the list of supported Storage Upgrade Key. Table 5. Intel® RAID C600-A Storage Upgrade Key Options for S1600JP Intel® RAID C600 Upgrade Key Key Color Options (Intel® Product Codes) Description Default - No option key installed N/A 4 Port SATA with Intel...
System Service Guide - Page 49

... Installations and Upgrades Figure 55. Installing the Intel® Storage Upgrade Key Installing and Removing the Fan Removing the Fan set 1. Disconnect the Fan cable. 2. Remove Fan set from dock. Figure 56. Removing the Fan Installing the Fan set 1. Place the Fan set into dock. 2. Connect the Fan set cable to connector on the motherboard. Intel® Server System R1000JP Family Service Guide...
System Service Guide - Page 73

...1 Waiting for user input 0xE8h 1 1 1 0 1 0 0 0 Checking password 0xE9h 1 1 1 0 1 0 0 1 Entering BIOS setup 0xEAh 1 1 1 0 1 1 0 0 Flash Update 0xEBh 1 1 1 0 1 1 0 1 Legacy Option ROM initialization 0xECh 1 1 1 0 1 0 0 0 DXE Drivers initialized 0xEDh 1 1 1 0 1 0 0 1 Transfer control to Boot Device Selection (BDS) 0xEEh Calling Int 19. One beep...
System Service Guide - Page 74

...all Intel® Enterprise Server and Storage Platforms. Information available at the support site includes:  Latest BIOS, firmware, drivers, and utilities.  Product documentation, installation and quick start guides.  Full product specifications, technical advisories, and errata.  Compatibility documentation for memory, hardware add-in cards, chassis support matrix...
System Service Guide - Page 77

...RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number: Detailed description of issue: Intel® Server System R1000JP Family Service Guide...
Technical Product Specification - Page 39

... MegaRAID SW RAID technology supporting SATA RAID levels 0,1,10, 5.  Intel® Rapid Storage Technology (RSTe) supporting SATA RAID levels 0, 1, 5, and 10. The server board is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with one of the several available Intel® RAID C600 Storage Upgrade Keys. Upgrade keys install onto...
Technical Product Specification - Page 42

... host controller can instruct the PCH to generate any of SMI#, NMI, SERR#, or TCO interrupt.  Function Disable: The Intel® C600 PCH provides the ability to disable the following integrated functions: LAN, USB, LPC, Intel® HD Audio, SATA, PCI Express*, or SMBus*. Once disabled, these functions no longer decode I/O, memory, or PCI configuration space. Also, no interrupts or power...
Technical Product Specification - Page 50

...the server board is integrated and any additional system level components and options that may be installed. 4.1.1   IPMI 2.0 Features Baseboard Management Controller (BMC) IPMI Watchdog timer Messaging support, including command bridging and user/session support. Chassis device functionality, including power/reset control and BIOS boot flags support. Event receiver device: The...
Technical Product Specification - Page 63

... The Intel® Server Board S1600JP product includes support for an upgrade module to support the advanced server management functionality. Table 21. Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State...
Technical Product Specification - Page 66

... is intended to allow system administrators or users to mount a remote USB HDD or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this...
Technical Product Specification - Page 67

... BIOS boot order to boot from this remote device.  It is possible to install an operating system on a bare metal server (no OS present) using the remotely mounted device. This may also require the use of KVM-r to configure the OS during install.  USB storage devices will appear as floppy disks over media redirection. This allows for the installation of device drivers...
Technical Product Specification - Page 74

...Power and Firmware Startup On Intel® Server Board S1600JP, the ME is on standby power....update is only supported by means of BIOS performing a direct update of the flash component. The recovery image only provides the basic functionality that is required to perform the update; therefore other ME FW features are not functional therefore when the update is in progress. 4.14.6 SmaRT/CLST The power...
Technical Product Specification - Page 247

... 0 0 1 0 1 Started dispatching drivers 1 1 1 0 0 1 1 0 Started connecting drivers DXE Drivers 1 1 1 0 1 1 0 1 Waiting for user input 1 1 1 0 1 0 0 0 Checking password 1 1 1 0 1 0 0 1 Entering BIOS setup 1 1 1 0 1 1 0 0 Flash Update 1 1 1 0 1 1 0 1 Legacy Option ROM initialization 1 1 1 0 1 0 0 0 DXE Drivers initialized 1 1 1 0 1 0 0 1 Transfer control to Boot Device Selection (BDS...
Technical Product Specification - Page 65

... AHCI controller SATA on board connectors  Four 3 Gb/sec SATA ports routed from the AHCI controller to SATA on board connectors  One mini-SAS connector labeled "SAS_0-3" to support SCU0. With the addition of one of several available Intel® RAID C600 Upgrade Keys, the system is capable of supporting additional embedded SATA, SAS, and software RAID options. Upgrade keys install...
Technical Product Specification - Page 66

... memory and CPU utilization.  Supported RAID Levels - 0, 1, 5, 10. o 4 and 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key. o 4 and 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key.  Maximum drive support = 8. o Note: ESRT2 has no SAS Expander Support.  Open Source Compliance = Binary Driver...
Technical Product Specification - Page 67

...® Server System R1000JP FamilyTPS Storage Controller Options Overview 6.2.2 Intel® Rapid Storage Technology (RSTe)1 Features of the embedded software RAID option Intel® Rapid Storage Technology (RSTe) include the following:  Software RAID with system providing memory and CPU utilization.  Supported RAID Levels - 0, 1, 5, 10. o 4-Port SATA RAID 5 available standard...
Technical Product Specification - Page 86

...live networking environment. This includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The system software can be updated using the Intel® Deployment CDROM that came with your system or can be downloaded from the Intel® website referenced at the bottom of this page.  System fans are not hot-swappable.  Only supported memory validated by Intel®...
Get Help Online

Get immediate support for your Intel R1000JP questions from HelpOwl.com.

Recent Intel R1000JP-related questions:

Intel Manuals

Find free Intel R1000JP manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.