Service guide for Intel Server Board S2600CW Family - Page 2

... the given product's Monthly Specification Update which can be downloaded from the following Intel website http://www.intel.com/support This document and the software described in it are furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only...
Service guide for Intel Server Board S2600CW Family - Page 5

... kits that may be installed in the system. Chapter 4 - System Software Updates and Configuration - provides instructions for completing the integration of the server chassis by updating the system software and navigating through the BIOS Setup screens. System Service Chapter 5 - System Features Overview - provides a high level overview of the Intel® Server Board S2600CW and Intel® Server...
Service guide for Intel Server Board S2600CW Family - Page 6

...For system power budget guidance For system firmware updates and onboard device drivers and software to manage your Intel® Server Chassis. Product Safety and Regulatory Information Use this Document or Software Intel® Server Board S2600CW Technical Product Specification Intel® Server Board S2600CW Product Family Spares and Accessories List and Configuration Guide Intel® Server...
Service guide for Intel Server Board S2600CW Family - Page 8

... 8x2.5" PCIe SSD (NVMe) Combo Drive Bay Stoarge 42 2.7.6 Upgrade the Fixed Drive Storage to 8x3.5" Hot-swap Drive Bay Stoarge 46 2.7.7 Upgrade the Fixed Drive Storage to 16x2.5" Hot-swap Drive Bay Stoarge 48 2.7.8 4 x 3.5" Front Drive Bay Storage ...50 2.7.9 8 x 2.5" Front Drive Bay Storage ...53 3. Option and Accessory Kit Integration and Service 55 3.1 Optical Drive - Installation and...
Service guide for Intel Server Board S2600CW Family - Page 74

... configure system settings that determine how the server operates. 4.2.1 Entering BIOS Setup To enter the BIOS Setup using a keyboard (or emulated keyboard), press the function key during boot time when the OEM or Intel Logo Screen or the POST Diagnostic Screen is displayed. Note: At intial system power-on, a USB Keyboard will not be functional until the USB controller has been...
Service guide for Intel Server Board S2600CW Family - Page 86

... technical support information on all Intel Enterprise Server and Storage Platforms. Information available at the support site includes: - Latest BIOS, firmware, drivers and utilities - Product documentation, installation and quick start guides - Full product specifications, technical advisories and errata - Compatibility documentation for memory, hardware add-in cards, chassis support matrix...
User Guide - Page 21

... a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. After mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device. • KVM - Automatically senses video resolution for...
User Guide - Page 62

Getting Started with Intel® RMM4 Operation Intel® BMC And RMM4 User Guide 5. Getting Started with Intel® RMM4 Operation The Intel® RMM4 module features remote KVM access and control through LAN or Internet. The Intel® Integrated BMC Web Console is part of the standard BMC firmware / Server Management Software. The Integrated BMC Web Console feature is used to access...
User Guide - Page 63

... User Guide Getting Started with Intel® RMM4 Operation In order to use the Remote Console (KVM) window of your managed server, Java* Runtime Environment (JRE) Version 6 Update 22 or higher must be installed. Note: The Web Console is designed for a screen size of 1280 pixels by 1024 pixels or larger. In smaller screens, the browser displays slider controls...
User Guide - Page 68

... where the Intel® RMM4 module is installed. Launch the remote console KVM redirection window from this page. Note: If you are using Microsoft Windows Internet Explorer*, the Smart Screen is enabled, and the system is on a network with no direct connectivity to the internet, it may take an extremely long time to open a KVM window. Figure 44: Remote Control Console...
User Guide - Page 69

... User Guide Remote Console (KVM) Operation Both Microsoft Internet Explorer* and Mozilla Firefox* browsers are supported. Notes: • Java* Runtime Environment (JRE, Version 6 Update 22 or higher) must be installed on the client before the launch of a JNLP file. • The client browser must allow pop-up windows from the Integrated BMC Web Console IP address. Figure 45: Remote Console...
User Guide - Page 77

... are unchecked in the Remote Console window. Note: The virtual devices are not limited to normal floppy/CDROM sizes and will be as large as the device or file being redirected. A USB Key drive is redirected as a virtual floppy device rather than a USB device to allow the loading of custom device drivers during remote OS installation which may require a floppy drive. There is only one...
User Guide - Page 131

... And RMM4 User Guide 7.4 Remote Control Tab Intel® Integrated BMC Web Console Options The Remote Control tab helps you perform the following remote operations on the server: • Console redirection • Server power control 7.4.1 Console Redirection Page By default, the Remote Control tab opens the Console Redirection page. Launch the remote console KVM redirection window from this...
Technical Product Specification - Page 53

... two embedded AHCI SATA controllers. By using Intel® RSTe, there is no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:  The SW-RAID option must be enable in BIOS SetupIntel® RSTe option must be selected in BIOS SetupIntel® RST drivers must be loaded for the specified...
Technical Product Specification - Page 66

...-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions. The server board implements TPM as per TPM PC Client Specifications revision 1.2 by the Trusted Computing Group (TCG). A TPM device is optionally installed onto a high density 14...
Technical Product Specification - Page 69

... server board is integrated and any additional system level components and options that may be installed. 5.1.1 IPMI 2.0 Features Overview  Baseboard management controller (BMC)  IPMI Watchdog timer  Messaging support, including command bridging and user/session support  Chassis device functionality, including power/reset control and BIOS boot flags support ...
Technical Product Specification - Page 70

... Intel® Server Board S2600CW2 TPS  Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of system SDRs.  Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It polls sensors to monitor and report system health.  IPMI interfaces - Host interfaces include system management software...
Technical Product Specification - Page 85

... Intel® Server Board S2600CW2 Platform Management implements fan presence sensors for each hot-swappable fan. These are instantiated as IPMI discrete sensors. Events are only logged for fan presence upon changes in the presence state after AC power is applied (no events logged for initial state). 5.3.13.3 Fan Redundancy Sensor The BMC supports...
Technical Product Specification - Page 99

...mail Alerting Embedded Web Server SSH Support Integrated KVM Integrated Remote Media Redirection Lightweight Directory Access Protocol (LDAP) Intel® Intelligent Power Node Manager Support SMASH CLP Basic X X X X X X X X X X X X X X X X X Advanced X X X X X X X X X X X X X X X X X X X On the server board the Intel® RMM4 Lite key is installed at the following location. Revision 1.0 85
Technical Product Specification - Page 100

... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.  KVM - Automatically senses video resolution for best...
Get Help Online

Get immediate support for your Intel S2600CW questions from HelpOwl.com.

Recent Intel S2600CW-related questions:

Intel Manuals

Find free Intel S2600CW manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.