Intel S2600WT driver and firmware
Related Intel S2600WT Manual Pages
Download the free PDF manual for Intel S2600WT and other Intel manuals at ManualOwl.com
User Guide - Page 21
... a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. After mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device.
• KVM - Automatically senses video resolution for...
User Guide - Page 62
Getting Started with Intel® RMM4 Operation
Intel® BMC And RMM4 User Guide
5. Getting Started with Intel® RMM4 Operation
The Intel® RMM4 module features remote KVM access and control through LAN or Internet. The Intel® Integrated BMC Web Console is part of the standard BMC firmware / Server Management Software. The Integrated BMC Web Console feature is used to access...
User Guide - Page 63
... User Guide
Getting Started with Intel® RMM4 Operation
In order to use the Remote Console (KVM) window of your managed server, Java* Runtime Environment (JRE) Version 6 Update 22 or higher must be installed.
Note: The Web Console is designed for a screen size of 1280 pixels by 1024 pixels or larger. In smaller screens, the browser displays slider controls...
User Guide - Page 68
... where the Intel® RMM4 module is installed. Launch the remote console KVM redirection window from this page.
Note: If you are using Microsoft Windows Internet Explorer*, the Smart Screen is enabled, and the system is on a network with no direct connectivity to the internet, it may take an extremely long time to open a KVM window.
Figure 44: Remote Control Console...
User Guide - Page 69
... User Guide
Remote Console (KVM) Operation
Both Microsoft Internet Explorer* and Mozilla Firefox* browsers are supported.
Notes:
• Java* Runtime Environment (JRE, Version 6 Update 22 or higher) must be installed on the client before the launch of a JNLP file.
• The client browser must allow pop-up windows from the Integrated BMC Web Console IP address.
Figure 45: Remote Console...
Technical Product Specification - Page 23
Intel® Server Board S2600WT TPS
2.3 System Software Overview
The server board includes an embedded software stack to enable, configure, and support various system functions. This software stack includes the System BIOS, Baseboard Management Controller (BMC) Firmware, Management Engine (ME) Firmware, and management support data including Field Replaceable Unit (FRU) data, and Sensor Data ...
Technical Product Specification - Page 27
Intel® Server Board S2600WT TPS
Instructions provided with the system update package downloaded from the Intel web site. Once the update has completed, the recovery jumper is switched back to its default position and the system is power cycled.
If the BIOS detects a partial BIOS update or the BMC asserts Recovery Mode GPIO, the BIOS will boot up with Recovery Mode. The difference is that the...
Technical Product Specification - Page 57
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 101
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device. • KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 118
Intel® Server Board S2600WT TPS
11.2 Serial Port 'A' Configuration Jumper
See section 5.10 for details
11.3 Password Clear Jumper Block
This jumper causes both the User password and the Administrator password to be cleared if they were set. The operator should be aware that this creates a security gap until passwords have been installed again through the BIOS Setup utility. This is the only...
Technical Product Specification - Page 119
... should only be used if the BMC firmware has gotten corrupted and requires re-installation. The following procedure should be followed:
Note: System Update files are included in the System Update Packages (SUP) posted to Intel's Download center web site. http://downloadcenter.intel.com
1. Turn off the system. 2. Remove the AC power cords
Note: If the BMC FRC...
Technical Product Specification - Page 44
... Data Records (SDRs) for any given system configuration must be loaded by the system integrator as part of the initial system integration process. SDRs are loaded using the FRUSDR utility which is part of the System Update Package (SUP) or One-boot Firmware Update (OFU) package which can be downloaded from the following Intel website:
http://downloadcenter.intel.com...
Technical Product Specification - Page 73
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 88
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.
KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 92
.... However, to ensure the latest sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
Make sure the latest system software is loaded on the server. This includes System BIOS, BMC Firmware, ME Firmware and FRUSDR. The latest system software can be downloaded from http://downloadcenter.intel.com.
82
Revision 1.0
Technical Product Specification - Page 60
... sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
The FRUSDR utility for the given server platform can be downloaded as part of the System Update Package (SUP) or One-boot Firmware Update (OFU) package which from the following Intel web site:
http://downloadcenter.intel.com.
Note: The...
Technical Product Specification - Page 64
... Card - System Configuration Requirements
For best system performance and proper fan speed control, ensure the system is configured as follows:
• The following BIOS Setup Utility Options must be set:
MMIO over 4GB = Enabled MMIO Size = 256GB
Intel highly recommends that the latest available system software be installed. The latest system update package can be downloaded...
Technical Product Specification - Page 95
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 117
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.
• KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 121
.... However, to ensure the latest sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
Make sure the latest system software is loaded on the server. This includes System BIOS, BMC Firmware, ME Firmware and FRUSDR. The latest system software can be downloaded from http://downloadcenter.intel.com.
Revision 1.0
109