TP-Link T2600G-28MPSTL-SG3424P driver and firmware
Drivers and firmware downloads for this TP-Link item
Related TP-Link T2600G-28MPSTL-SG3424P Manual Pages
Download the free PDF manual for TP-Link T2600G-28MPSTL-SG3424P and other TP-Link manuals at ManualOwl.com
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 6
...user access-control mac-based 84 user access-control port-based 85 line ...85 password ...86 login ...88 login local...88 media-type rj45 ...89 telnet ...90 serial_port baud-rate...90 show password-recovery 91 ... 99 ip http secure-session timeout 100 ip http secure-server download certificate 101 ip http secure-server download key 101 show ip http configuration 102 show ip http secure-server...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 9
...-id(interface 160 pppoe circuit-id type ...160 pppoe remote-id ...161 show pppoe id-insertion global 162 show ...flash ...173
Chapter 25 SSH Commands 175
25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8
ip ssh server...175 ip ssh version ...175 ip ssh algorithm ...176 ip ssh timeout ...177 ip ssh max-client ...177 ip ssh download...178 remove public-key ...179 show ip ssh...179
Chapter 26 MAC Address...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 10
... 198 hostname...199 location ...200 contact-info ...200 ip address ...201 ip address-alloc...202 reset ...203 reboot...203 reboot-schedule ...204 copy running-config startup-config 205 copy startup-config tftp 205 copy tftp startup-config 206 boot application ...207 remove backup-image ...207 firmware upgrade...208 boot autoinstall start ...209 boot autoinstall persistent-mode 209...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 11
... autoinstall downloaded-config ...cpu-utilization...220 show memory-utilization 221
Chapter 28 IPv6 Address Configuration Commands 222
28.1 28.2 28.3 28.4 28.5 28.6 28.7 28.8
ipv6 enable ...222 ipv6 address autoconfig 222 ipv6 address link-local ...223 ipv6 address dhcp ...224 ipv6 address ra ...224 ipv6 address eui-64 ...225 ipv6 address ...226 show ipv6 interface ...226
Chapter 29 Ethernet...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 24
... the switch, upgrade the switch system and commands used for cable test. Chapter 28: IPv6 Address Configuration Commands Provide information about the commands used for configuring the System IPv6 addresses. Chapter 29: Ethernet Configuration Commands Provide information about the commands used for configuring the Bandwidth Control, Negotiation Mode, and Storm Control for enthernet ports. Chapter...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 26
... USB port on the MAC OS X or Linux OS for console connection, there is no need to run a USB driver. If you are using the switch's Micro-USB console port with the USB port of a Windows PC, a driver for the USB port is required. The USB driver is provided on the resource CD. Follow the InstallSheild Wizard to accomplish the installation. The TP-Link USB Console Driver supports the following Windows...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 27
64-bit Windows 8 32-bit Windows 8.1 64-bit Windows 8.1 After the TP-Link USB Console Driver is installed, the PC's USB port will act as RS-232 serial port when the PC's USB port is connected to the switch's Micro-USB console port. And the PC's USB port will act as standard USB port when the PC's USB port is unplugged from the switch. Logon Take the following ...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 29
... Telnet in login local mode. 1. Make sure the switch and the PC are in the same LAN. Click Start and type in cmd in the
Search programs and files window and press the Enter button.
Figure 1-4 Run Window 2. Type telnet 192.168.0.1 in the command prompt shown as Figure 1-5, and press the Enter...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 31
...
Search programs and files window and press the Enter button.
Figure 1-9 Run Window 2. Type telnet 192.168.0.1 in the command prompt shown as Figure 1-10, and press the
Enter button.
Figure 1-10 Connecting to the Switch 3. You are prompted to enter the connection password 456 you have set through Console
port connection, and then you...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 32
... information of the Telnet connection configuration.
1.1.3 Logon by SSH
To log on by SSH, a Putty client software is recommended. There are two authentication modes to set up an SSH connection: Password Authentication Mode: It requires username and password, which are both admin by default. Key Authentication Mode: It requires a public key for the switch...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 33
Password Authentication Mode 1. Open the software to log on to the interface of PuTTY. Enter the IP address of the switch
into Host Name field; keep the default value 22 in the Port field; select SSH as the Connection type.
Figure 1-14 SSH Connection Config 2. Click the Open button in the above figure to...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 35
2. After the key is successfully generated, please save the public key and private key to a TFTP server.
Figure 1-17 Save the Generated Key 3. Log on to the switch by Telnet and download the public key file from the TFTP server to the
switch, as the following figure shows:
Figure 1-18 Download the Public Key
14
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 37
... private key file to SSH client software and click Open.
Figure 1-20 Download the Private Key 6. After successful authentication, please enter the login user name. If you log on to the
switch without entering password, it indicates that the key has been successfully downloaded.
Figure 1-21 Log on the Switch
1.2 CLI Command Modes
The...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 229
... level users have access to these commands.
Example
Upgrade the switch's backup iamge file with the file firmware.bin in the TFTP server with the IP address 192.168.0.148, and reboot the switch with this firmware: T2600G-28TS# firmware upgrade ip-address 192.168.0.148 filename firmware.bin
It will only upgrade the backup image. Continue? (Y/N):y Operation OK! Reboot...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 230
T2600G-28TS# firmware upgrade ip-address fe80::1234 filename firmware.bin It will only upgrade the backup image. Continue? (Y/N):y
Operation OK! Reboot with the backup image? (Y/N): n
27.20 boot autoinstall start
Note: Only T2600G-18TS supports this command.
Description
The boot autoinstall start command is used to start Auto Install function. To stop the Auto Install function, use no boot ...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 231
... persistent-mode
27.22 boot autoinstall auto-save
Note: Only T2600G-18TS supports this command.
Description
The boot autoinstall auto-save command is used to automatically save the new configuration file that was downloaded by Auto Install function to start-up configuration file Auto Install. To disable auto-save configuration feature use no boot autoinstall...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 232
... auto-reboot
27.24 boot autoinstall retry-count
Note: Only T2600G-18TS supports this command.
Description
The boot autoinstall retry-count command is used to configure retry count when Auto Install function uses TFTP to download configuration files in a cycle of Auto Install process. To set retry count to default value use no boot autoinstall retry...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 233
... function: T2600-18TS# show boot autoinstall
27.26 show boot autoinstall downloaded-config
Note: Only T2600G-18TS supports this command.
Description
The show boot autoinstall downloaded-config command is used to display the configuration file which downloaded by Auto Install.
Syntax
show boot autoinstall downloaded-config
Command Mode
Privileged EXEC Mode and Any Configuration Mode
Privilege...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 234
Example
Display the configuration file which downloaded by Auto Install: T2600-18TS# show boot autoinstall downloaded-config
27.27 ping
Description
The ping command is used to test the connectivity between the switch and one node of the network.
Syntax ping [ ip | ipv6 ] { ip_addr } [ -n count ] [ -l count ] [ -i count ]
Parameter
ip -- The type of the IP address for ping...
T2600G-28MPSUN V2 CLI Reference Guide Guide - Page 403
... for port 3: T2600G-28TS(config)# interface gigabitEthernet 1/0/3 T2600G-28TS(config-if)# snmp-server traps link-status
41.10 snmp-server traps
Description
The snmp-server traps command is used to enable SNMP extended traps. To disable the sending of SNMP extended traps, please use no snmp-server traps command.
Syntax
snmp-server traps { bandwidth-control | cpu | flash...