HP StorageWorks Modular Smart Array controller, cache, and battery replacement instructions (February 2006) - Page 4
.... See the MSA1510i maintenance and service guide for more information.
• MSA1000/MSA1500 cs-Due to parts availability, replacement controllers might ship with a new firmware version that is required for that controller model. If older firmware is installed on the active controller and newer firmware is installed on the replacement controller, cloning might fail. To update the firmware on the...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 7
... 34 3 Levels of protection against power failure 53 4 MSA1510i normal status lights 55 5 MSA1510i controller LCD startup messages 56 6 Version information worksheet: firmware, driver, and software components 80 7 LCD message descriptions 107 8 Basic MSA1510i information 142 9 MSA1510i 2-Port Ethernet iSCSI module IP address information 143 10 Network switch information 145 11 Server...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 32
...www.hp.com/go/e-updates.
2. Under Driver and Support alerts, click Subscribe.
3. Under Select a product family, scroll down and click Storage to display a listing of all HP products. Then, scroll down and click MSA Disk Arrays. All MSA products will be displayed.
4. Click each MSA product for which you want to receive notices. For example: HP StorageWorks 1510i Modular Smart Array, HP StorageWorks...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 34
... your MSA1510i or other HP devices: http://www.hp.com/go/e-updates.
• Use the MSA1510i installation and configuration roadmap poster to guide you through the installation and configuration process.
• Periodically check the MSA1510i website for firmware updates and other announcements. HP may place new versions of MSA controller firmware (or other support items...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 79
... must be updated at the same time.
1. Record the currently-installed versions of firmware, driver, and software components. (Table 6) Consider using some of the following system tools to obtain this information: • Internet browser (to access some software user interfaces) • Windows Device Manager • SmartStart Survey Utility • HP Systems Insight Manager (HP-SIM) •...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 80
...-available
installed version version
Update ?
Operating system
Y/N
Operating system patch kit
Y/N
Initiator
Y/N
Multipathing software
Y/N
Device Specific Module (DSM)
Y/N
Switch firmware
Y/N
SCSI hard drive firmware
Y/N
MSA1510i firmware
Y/N
MSA20 firmware
Y/N
NOTE: To determine the firmware version currently running on an MSA controller, do...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 81
...-controller MSA1510i configurations, only one of the two MSA controllers is updated directly. The second MSA controller is updated (cloned) when the MSA is power-cycled after completing the update of the first controller. • Depending on the storage enclosure model attached to the MSA array (SATA or SCSI), you may be able to update enclosure firmware or hard drive...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 82
... MSA1510i Controller. Then, read the Device Information in the right pane of the screen and look for the Firmware Version.
2. Obtain the latest firmware files and save to a temporary location on the host: a. Navigate to the MSA1510i support page: http://www.hp.com/go/support. b. Click the title description of the download option to display important information about the update...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 87
... status window is displayed.
11. Wait for a completion message to display. For example, the following messages are displayed on the MSA controller LCD panel:
MSA1510i update: 307 FIRMWARE FLASH DONE MSA20 update: 313 FIRMWARE FLASH DONE ON BOX (Each attached storage enclosure is updated one at a time, in sequential box number order.)
NOTE: Do not interfere with or cancel the download process...
HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008) - Page 91
... a firmware corruption, the following message is displayed on the LCD panel:
ERROR: ROM CORRUPT
SEND IMG VIA XMODEM To recover the controller, you must obtain a current firmware image and send it to the controller using a serial connection.
1. Go to the MSA1510i support website and obtain the latest controller firmware.
NOTE: If you are not yet registered, select...
HP Storage Management Utility user guide (383075-002, July 2008) - Page 9
... guide, which discuss important reference information and specifications. • Click Software, Firmware & Drivers to learn about recent firmware enhancements and support options.
Related documentation
The following documents describe the MSA1510i: • HP StorageWorks 1510i Modular Smart Array release notes • HP StorageWorks 1510i Modular Smart Array installation...
HP Storage Management Utility user guide (383075-002, July 2008) - Page 17
... MSA1510i by opening a command prompt window and using the ping command.
Best practices
• Go to the HP storage website: http://www.hp.com/storage for your array controller. Product websites are updated to include the latest: • Hardware, firmware, and driver compatibility information. • Firmware and/or software. • System documentation.
• Use provided installation...
HP Storage Management Utility user guide (383075-002, July 2008) - Page 79
6 Update
Updating system firmware (Flash Firmware)
Available tasks
As shown in Figure 14, the Update tab includes two options: • Updating MSA firmware • Updating hard drive firmware
Figure 14 Update tab-task listing
Prerequisites
Before updating system firmware, make note of the following:
• When determining which MSA controller firmware version to ...
HP Storage Management Utility user guide (383075-002, July 2008) - Page 80
....
Updating MSA firmware
1. Determine which version firmware is currently installed on the MSA by using one of the following methods: • With the array controller powered on, press the arrow buttons on the front of the controller until the following message is displayed: 00 Array Controller Firmware ver . • From the SMU, select View MSA1510i Controller. Then, view the Device...
HP Storage Management Utility user guide (383075-002, July 2008) - Page 96
...settings, 56 installation, configuration HP assistance, 11 installing the array controller, 17 IP addresses assigning TCP ports to, 37 entering, 36 obtaining the default, 15 iSCSI Initiator Name, 50 iSCSI view, 26 iSNS Discovery Mode, 65 iSNS Discovery Settings task, described, 65
L
load balancing, defined, 88 logical drive
characteristics, changing, 58 logical drives
changing the RAID...
HP StorageWorks 1510i Modular Smart Array installation and configuration roadmap (383069-003, July 2008) - Page 4
...
Upgrade to active/active
The MSA1510i Support CD guides you through the process of upgrading the MSA1510i from the factory-installed active/passive firmware to active/active firmware. For a new MSA1510i, perform these upgrades before configuring the storage. The following steps are executed from the CD: • Obtaining the latest versions of Microsoft iSCSI initiator software...
HP StorageWorks 1510i Modular Smart Array Command Line Interface user guide (383074-002, July 2008) - Page 61
...00 Array Controller Firmware ver . • From the MSA-CLI, enter the show version command. MSA1510i Firmware Revision is included in the displayed system information.
2. Obtain the latest firmware files and save to a temporary location on the host:
a. Go to the MSA1510i support page: http://www.hp.com/support.
b. Select your language and operating system.
c. The display is updated to...
HP StorageWorks 1510i Modular Smart Array Firmware v1.32 Release Notes (441888-001, January 2007) - Page 4
... Software CD version 1.20 must be downloaded and used to update host drivers and utilities that are compatible with the active/passive firmware.
Installation instructions
For instructions on installing the firmware, see the HP Storage Management Utility guide located on the Technical Documents page of the MSA 1510i website: http://www.hp.com/go/msa1510i.
NOTE: Dual controller...
HP StorageWorks 1510i Modular Smart Array firmware 2.02 release notes (431339-002, March 2009) - Page 6
... updating MSA20 firmware, the controller shelf and ALL MSA20 and MSA30 attached storage enclosures must be power-cycled.
• Any attached MSA20 storage enclosures must be at firmware version 2.08 prior to installing MSA1510i firmware version 2.02.
Installation instructions
If your MSA1510i setup includes one or more attached MSA20 storage enclosures, you must update the firmware on all MSA20s...
HP StorageWorks 1510i Modular Smart Array firmware 2.02 release notes (431339-002, March 2009) - Page 7
... system is restarted, the new firmware will automatically be cloned from the just-updated controller over to the other controller. For more information, see the "Redundant-controller firmware cloning" instructions in the HP StorageWorks 1510i Modular Smart Array maintenance and service guide.
Determining installed version