Disk Drive and Power Supply LED Behavior - Page 2
...4 of the HP StorageWorks Disk System 2300 User's Guide or HP StorageWorks Disk System 2405 User's Guide for troubleshooting procedures.)
Table 2: DS2300 / DS2405 Disk Drive LEDs Status Indications
A Disk Activity (Green*) ON
Flashing
OFF ON/OFF
OFF
B Disk Fault (Amber**)
Indication
OFF
Installed and spinning up. If the LED is still on 3 minutes
after power is engaged, the disk may be faulty...
Appendix A. Disk Array Controller Log - Page 4
... while
auto-rebuild is enabled.
Disk Drive Stamp Write Failed Y
Single
Disk Drive,
N In order to make a drive a member of a volume set it
Occurrance - See Controller, Disk
must have a stamp written onto it by the controller.
accompanying Interface
This error indicates that the writing or updating of
errors
the stamp failed during an add physical drive
command, causing the command to...
Appendix A. Disk Array Controller Log - Page 5
...Occurrance
Single Occurrance
Ingore
Disk Drive Disk Drive None
65/0x41
Optimal Space Error In RAID Y 1
Ignore
None
66/0x42 No Shutdown Image Posted
N
67/0x43 Bad Disk Drive State During N Add Physical Drive
68/0x44 69/0x45
Disk Interface Data Underrun Y
Disk Interface Data Overrun
Y
N.A. N.A.
N.A. N.A.
None None
None None
N An offline controller firmware download was attempted while...
Appendix A. Disk Array Controller Log - Page 6
... command is not possible in current subsystem
required
state.
Data loss detected
Y
N.A.
None
Y An otherwise successful read op failed due to data
loss recorded in at least 1 of the disk blks read This
is a rev2 error; the error is defined but not used in
rev1 firmware.
Insufficient memory resources N
N.A.
None
N There is not enough memory installed in the
Appendix A. Disk Array Controller Log - Page 7
... card) volume set
was used in a recover command then this error
means that the controller found drives from multiple
volume sets present. If a non-null volume set uas
used then this error means that the contoller is
already attached to a volume set other than the one
referenced in the recover command.
Recovery From RAM Loss
Y
Single
Disk Drive,
Y This error indicates that the controller...
Appendix A. Disk Array Controller Log - Page 9
... is self correcting.
N The firmware made a decision to automatically fail a disk device due to its accumulated error history.
N During startup a disk stamp newer than the NVRAM committed stamp copy was found. This indicates the volume set attached successfully to a different controller and this VS related NVRAM is not valid.
N During startup a quorum of the drives belonging to the volume...
Appendix A. Disk Array Controller Log - Page 12
... 295/0x127 296/0x128 297/0x129
Memory Compare Error
Controller Data Bus Microprocessor Access Parity Error Internal Data Bus Error Volume Set Full Reset
Warm Boot IO Expander Fault Disk Set Detached
Microprocessor Software Fault
Microprocessor Hardware Fault Disk Interface Event Insufficient RAM For Image Upload
Disk Interface Queueing Disabled Disk Disconnects Disabled
Y
Ingore - See SDRAM...
Appendix A. Disk Array Controller Log - Page 14
...
used.
Drive Missing At Power On
Y Ignore unless no Disk Drive,
N This error code indicates that a drive was discovered
Operator activity Controller,
to be missing during a power on or reset. This event
Back End FC
occurs for volume set members only. The device
Link
number of the drive removed appears in this change
record. A device number consisting of the
controller serial number...
Appendix A. Disk Array Controller Log - Page 15
...
This can be caused by the controller having
difficulty in establishing communication. Ignore if
recovered by power cycle or reset.
SIMM Failed
Y
Single
SIMM,
N This error code indicates that a SIMM was
Occurrance Controller
discovered to be bad during the poweron process.
Extended Drive Insertion Event Y Ignore unless no Disk Drive,
N A backend SCSI channel was held reset longer than...
Appendix A. Disk Array Controller Log - Page 16
... if Disk Drive,
N This error code indicates that the parity scan which
followed by error Back End FC
executes during recovery from RAM loss found an
code 93 (0x5d) Link, Controller
instance of incorrect redundant data. Data which
was being updated when RAM was lost may
produce this error in single failure scenarios. This
error can also result from multiple failure
conditions. Firmware...
Appendix A. Disk Array Controller Log - Page 17
... Background Y
Ignore if
ROM,
N This error code indicates that the ROM on the local
ROM checksum test
recovered by Controller
controller failed the ROM checksum test done in the
reset or power on
background during idle time. The firmware stored
in the ROM is corrupted.
Scrub policy detected error
Y Ignore - should Disk drive
N This error code indicates that an error was returned
be...
Appendix A. Disk Array Controller Log - Page 19
... state change
Operator activity FC Port,
consisting of an LCC hot plug removal. The device
Controller
number of the lcc removed appears in this change
record. A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
DDM failed image disks
Y Ignore unless no disk drives
N This error code indicates the system...
Appendix A. Disk Array Controller Log - Page 21
...Controller, battery, power supply Controller, battery
NVRAM battery charger NVRAM battery
Controller, battery, power supply, midplane Controller, battery, power supply, midplane
download mode to update the charger firmware N The two-wire serial bus local to the controlle...management firmware module was unable to communicate with the NVRAM battery. Possible two-wire serial bus communication error.
Y...
Appendix A. Disk Array Controller Log - Page 23
...
487/0x1e7 software fault reset
Y
488/0x1e8 hardware fault reset
Y
controller controller controller
controller controller
489/0x1e9 abterm reset
Y
490/0x1ea front panel reset
Y
491/0x1eb host reset
Y
492/0x1ec firmware download reset
Y
controller controller controller controller
493/0x1ed controller failover reset
494/0x1ee 495/0x1ef
memory error reset dual controller comm failure...
Appendix A. Disk Array Controller Log - Page 25
... error
Y
Software address warning
Y
LCC switch address warning Y
Power supply not present
Y
Map Disk Event
Y
Power Supply Power Supply Controller
Controller
Controller Power Supply Controller
Battery NVRAM backup
Y
command
Unsupported host port behavior Y
table revision
Ignore
NVRAM battery charger None
Host Port Behavior table was initialized as empty Firmware download failed...
Appendix A. Disk Array Controller Log - Page 27
... Disk Driver Created
Y
569/0x239 Disk Driver Deleted
Y
570/0x23a Hot Plug Event
Y
571/0x23b New Device Found
Y
572/0x23c Old Device Lost
Y
573/0x23d Warning Indicator Activated Y
574/0x23e Warning Indicator Deactivated Y
575/0x23f PDM Label Table Mismatch Y
576/0x240 Uploaded mode parms were
Y
NA
None
defaulted
577/0x241 Start multi disk loss scan
Y Ignore. should controller...
Linux Configuration HP VA 7100/7400 - Page 2
... 7100/7400 and Command View SDM software have been tested using QLogic QLA2100 or QLA2200 fibre channel host bus adapters on Red Hat 6.2 with the 2.2.16-3 and 2.2.19-6.2.7 kernels patched as described herein. Other configurations may work, but are not yet supported. Specifically, these patches have not been tested in configurations with multiple SCSI devices (i.e., tape drives, CD ROMs...
Linux Configuration HP VA 7100/7400 - Page 5
... listed here and summarized below. 1. Command View 2. Device "Not Ready - LUN Becoming Ready" 3. Refined SCSI Error Recovery
There are versions of these patches for the Linux 2.2.16-3 and 2.2.19 kernels. The changes can be reached from http://www.hp.com. Follow the links to the VA 7100/7400 mid-range disk array storage products.
The patches are commented so that...
Linux Configuration HP VA 7100/7400 - Page 11
... fixes a select set of problems and is known to cause others. If you see device timeouts in system logs, devices being marked offline by the kernel, and/or file system corruptions, consider incorporating this patch.
Files Affected:
../linux/drivers/scsi/qlogicfc.c ../linux/drivers/scsi/qlogicfc.h ../linux/drivers/scsi/scsi_syms.c
3 Install Patches and Rebuild Kernel
1. Install Linux and the...
Linux Configuration HP VA 7100/7400 - Page 14
... 7100/7400
The Command View SDM software has a dependency on availability of certain fonts. We needed to install the fonts in: urw-fonts.tar.gz downloaded from: www.gimp.org/fonts.html. If you intend to run the Command View GUI client on the array host, the presence of these fonts will prevent a series of error...