HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 5
... installation and use of the HP SureStore E Disk Array and its management software. • HP SureStore E Disk Array FC60 Advanced User's Guide - this is the expanded version of the
book you are reading. Topics that are discussed in more detail in the Advanced User's Guide are clearly identified throughout this book.
!"Download: www.hp.com/support/fc60
• HP Storage Manager 60 User's Guide...
HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 232
...
Drive SCSI Channel 2 Turnaround diagnostics running
Drive SCSI Channel 3 Turnaround diagnostics running
Drive SCSI Channel 4 Turnaround diagnostics running
0x6C 0x05
Drive SCSI Channel 5 Turnaround diagnostics running
0x6E 0xEE 0x80
0x80 0x00
Passive controller - Normal during Firmware download. The controller may be in this state after power ON (in this case, use the AM60 software to set...
HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 241
... interface
No
problems?
End
Yes
Fault Condition
Yes
Check the Host for errors using STM, AM60 and syslog.log. Intermittnet problems can be caused by the following: 1. Missing patches
Install latest driver patches 2. Firmware level
Install latest Firmware levels 3. Unsupported configurations. 4. Host adapter 5. FC Cables 6. Controller Module
Go to
B
Controller Enclosure Troubleshooting 241
HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 336
...
Installing the Controller Module
Note
When a new controller module is installed, the resident controller checks the firmware version of the new controller. If the versions do not match, the resident controller downloads its firmware to the new controller module. This procedure, called Auto Code Synchronization (ACS), ensures that both controllers are operating with the same version of firmware...
HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 381
... "Use" means storing, loading, installing, executing, or displaying Software on a computer, processor, or controller, or making a copy of Software for archival or backup purposes only.
c. "Products" include hardware, Software, options, documentation, accessories, supplies, spare parts, and upgrades on HP's Price List on the date HP receives Customer's order.
License Grant. HP grants you a license...
HP SureStore E Disk Array FC60 Service Manual (A5635A) - Page 415
... causes 284 memory problems 239 overheating problems 252, 268 power shutdown 268 power supply problems 269 power system problems 261 power-up 213 table 284 through software 237 Windows NT tools 210
U unsupported topologies
Windows 98 upgrade and add-on products 364 UPS, recommended 119
V ventilation 328 verifying host to array path 172 voltage specifications
controller enclosure 369 disk enclosure...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 37
Controller
HP SureStore E Disk Array 12H Controller Downloading Array Controller Firmware
Downloading Array Controller Firmware
When two controllers are installed in the disk array enclosure (dual controllers), both controllers must have the same version of firmware. If you update (or download) new firmware, the new firmware is copied to both controllers. When a controller is replaced, however, ...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 39
...) to determine which download procedure to follow. Pick the appropriate procedure. NOTE! This procedure assumes that the Model 12 and HP SureStore E Disk Array 12H controllers have been updated to at least HP25 and HP24 firmware revisions, respectively. If they have not been updated to these versions of firmware, then refer to the service notes indicated below to update the array before continuing...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 40
Controller
HP SureStore E Disk Array 12H Controller Firmware Download Procedure
Figure 15. Downloading Controller Firmware Flowchart
Downloading Controller Firmware NOTE: Downloading firmware is an offline process. In most cases, the LUNs on the array need
to be either un-mounted or deactivated from the volume group.
Operating System Windows NT?
No
Perform the
Yes
Download Windows NT
...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 43
Controller
HP SureStore E Disk Array 12H Controller Firmware Download Procedure
Download Windows NT AutoRAID Manager includes a separate utility for downloading controller firmware. This utility, WinDownload, simplifies the process of downloading new firmware to the controller in your disk array. The WinDownload utility is used only for downloading firmware to the disk array controllers. Firmware...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 44
Controller
HP SureStore E Disk Array 12H Controller Firmware Download Procedure
Download A) Downloading Disk Array Firmware from a File Using ARMServer (AutoRAID Manager)
CAUTION! Controller firmware HP4x and any later versions have a different data map format in NVRAM memory. Once you have HP48 or later, you can not "downgrade" to any firmware version prior to HP4x without first completely ...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 52
... Specification".
1. Obtain a bootable LIF file. You can get the LIF file from the web: On the World Wide Web: • http://www.hp.com/go/support
• click next on "Enterprise Storage" • click next on "HP Enterprise Disk Arrays" • click next on "SureStore E Disk Arrays" • click next on "Disk Array 12H" • click GO on "Software/Firmware" beneath "Software & Drivers"
52
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 55
Controller
HP SureStore E Disk Array 12H Controller Firmware Download Procedure
Now to set the environment variables: 10. Run the DISPMAP command. This command allows you to display all available AutoRAID disk
arrays (controllers) on the system. Note the Test Disk # of the controller you've identified as the primary (by its path in ioscan). 11. Type TESTDISK_ # (where _ is a space and # is the ...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 56
... version of DFDUTIL_VHPxx.LIF (xx = the controller firmware revision) and copy
it the file /spp/data/DFDUTIL.LIF on the teststation. You can get the LIF file from the web:
On the World Wide Web: • http://www.hp.com/go/support
• click next on "Enterprise Storage" • click next on "HP Enterprise Disk Arrays" • click next on "SureStore E Disk Arrays...
HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999) - Page 128
... the power module!
Firmware Loading
EPROMs are being reprogrammed.
None. Information only.
Firmware Needed The controllers installed in the disk array have different firmware revisions. A new controller may have been installed that has a later version of firmware. The firmware revisions must be the same on both array controllers.
Perform ONE of the following procedures:
1) Copy firmware from...
HP SureStore E Disk Array FC60 Service Manual (A5277A) - Page 5
... and updated AM60 software.
Page 219 343
Change
Removed all references to HP08 to reflect the decision to roll supported controller firmware rolled back to HP03.
Page Multiple
Change
Added checksum values for HP10 firmware files and information regarding firmware download failure. Clarified procedure for binding multiple LUNs simultaneously. Added caution regarding powering down the array when...
HP SureStore E Disk Array FC60 Service Manual (A5277A) - Page 427
...are updated.
Informational (0x0)
Informational (0x0)
Informational (0x0)
Informational (0x0)
Informational (0x0)
Informational (0x0)
Informational (0x0)
Command (0x3)
Command (0x3)
Command (0x3)
Command (0x3)
Command (0x3)
Command (0x3)
Command (0x3)
Unknown (0x0)
Controller (0x8)
Controller (0x8)
Controller (0x8)
Controller (0x8)
Controller (0x8)
Controller (0x8)
Managing the Disk Array on HP...
HP SureStore E Disk Array FC60 - (English) Advanced User's Guide - Page 6
...8226; HP Storage Manager 60 Introduction Guide - this guide introduces the disk array management software for Windows NT and Windows 2000. It is included in electronic format on the HP Storage Manager 60 CD.
!"Download: www.hp.com/support/fc60
• Fibre Channel Mass Storage Adapters Service and User Manual (A3636-90002) - describes Fibre Channel Mass Storage/9000. It describes installation of...
HP SureStore E Disk Array FC60 - (English) Advanced User's Guide - Page 214
... be displayed indicating the version of HP-UX the host is running:
HP-UX myhost B.11.0.0 C 9000/750 1234567890 n-user license
Note
Controller firmware HP08 is not supported on HP-UX 11.11. If the disk array is being installed on a host running HP-UX 11.11, it will be necessary to downgrade the controller firmware to HP03 after installing the software.
Installing the Disk Array FC60 Software
The...
HP SureStore E Disk Array FC60 - (English) Advanced User's Guide - Page 431
... "Use" means storing, loading, installing, executing, or displaying Software on a computer, processor, or controller, or making a copy of Software for archival or backup purposes only.
c. "Products" include hardware, Software, options, documentation, accessories, supplies, spare parts, and upgrades on HP's Price List on the date HP receives Customer's order.
License Grant. HP grants you a license...