Intel X38ML - Server Board Motherboard driver and firmware

Drivers and firmware downloads for this Intel item

We have a direct link to download Intel X38ML drivers, firmware and other resources directly from the Intel site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

X38ML driver download page on the Intel site

Related Intel X38ML Manual Pages

Download the free PDF manual for Intel X38ML and other Intel manuals at ManualOwl.com

Product Specification - Page 2

Revision History Intel® Server Board X38ML Revision History Date September 2007 May 2008 April 2009 June 2010 Revision Number 1.0 Initial release. Modifications 1.1 iBMC fix to Integrated the BMC and fix the FAN sensors. 1.2 Corrected the heading typo at the top of some even numbered page. 1.3 Updated China CCC/CNCA related information. ii Revision 1.3 Intel order number...
Product Specification - Page 5

... 60 5.5 BMC Reset Control 60 5.5.1 BMC Exits Firmware Update 60 5.5.2 Standby Power Comes Up 60 5.6 System Initialization 60 5.6.1 Processor TControl Setting 60 5.6.2 Fault Resilient Booting (FRB 60 5.6.3 BSP Identification 61 5.6.4 Boot Control Support 61 5.6.5 Post Code Display 61 5.7 Integrated Front Panel User Interface 62 Revision 1.3 v Intel order number E15331-006
Product Specification - Page 17

... Board X38ML Server Board Overview Ref # 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Description NIC2 RJ-45 connector (J3A1) Integrated BMC Force Update Jumper Serial A DB-9 connector VGA connector Chassis intrusion header ServerEngines* Integrated BMC POST LED 2x5 USB header for USB 2 and 3 Intel® 82575EB LAN controller SMBus connector Intel® 82801IR ICH9R (J6B1) Password Clear jumper PCI...
Product Specification - Page 42

System BIOS Intel® Server Board X38ML Setup Item Hyper-Threading Technology Options Enabled Disabled Enhanced Intel® SpeedStep Technology Enabled Disabled Core Multiprocessing Enabled Disabled Intel® Virtualization Enabled Technology Disabled Execute Disable Bit Enabled Disabled Help Text Hyper-Threading Technology allows multi-threaded software applications to execute ...
Product Specification - Page 45

Intel® Server Board X38ML System BIOS Setup Item Onboard SATA Controller Configure SATA as SATA Port 0 SATA Port 1 SATA Port 2 SATA Port 3 Table 10. Setup Utility - ATA Controller Configuration Screen Fields Options Enabled Disabled IDE AHCI RAID < Not Installed/Drive information> < Not Installed/Drive information> < Not Installed/Drive information> < Not Installed/Drive information> ...
Product Specification - Page 63

Intel® Server Board X38ML System BIOS 4.6 Recovery Mode You can initiate the recovery process by setting the recovery jumper. The BIOS detects that the recovery jumper is set and executes code from the backup boot blocks. A BIOS recovery can be accomplished from a SATA CD-ROM and USB mass storage device. Recovery from USB floppy is not supported. A SATA CD image for recovery is created ...
Product Specification - Page 65

...buses, sensors, server management firmware, and system BIOS. The BMC on the Intel® Server Board X38ML is provided by the ServerEngines* Pilot-II integrated Baseboard Management Controller (Integrated BMC). This chapter provides an architectural overview of the Platform Management subsystem and the details of its features and functionality including BIOS interactions and support. 5.1 Platform...
Product Specification - Page 66

Platform Management Intel® Server Board X38ML 5.1.2 ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ Non-IPMI Features In-circuit BMC firmware update Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality Chassis intrusion detection and chassis intrusion cable presence detection. Basic fan control using TControl version 2 SDRs. Acoustic...
Product Specification - Page 72

Platform Management Intel® Server Board X38ML 5.4.5 BMC Command Used to Reset System Chassis Control is the primary command used to reset the system. 5.4.6 Watchdog Timer Expiration You can configure the watchdog timer to cause a system reset when the timer expires. See the Intelligent Platform Management Interface Specification, Version 2.0. 5.5 BMC Reset Control Table 30. BMC ...
Product Specification - Page 73

... processor is the BSP. You can use software to identify the BSP, as long as it uses the multiprocessor specification tables. See the BIOS EPS for additional details. 5.6.4 Boot Control Support The BMC supports the IPMI 2.0 boot control feature that allows the boot device and boot parameters to be managed remotely. 5.6.5 Post Code Display When the Integrated BMC receives standby power...
Product Specification - Page 78

... Specification, Version 2.0. When the BMC initializes or when the system boots, it scans the SDR repository and configures the IPMB devices that have management controller records and the Init Required bit set in their SDR repository. This includes setting sensor thresholds, enabling or disabling sensor event message scanning, and enabling or disabling sensor event messages. SDR Update mode does...
Product Specification - Page 84

Platform Management Intel® Server Board X38ML ƒ Chassis control command ƒ PEF action ƒ BMC watchdog timer ƒ Power state retention The BMC provides a system status on the front panel LEDs. For more information, refer to Section 5.7.2. 5.18 BMC Self Test The BMC performs ...
Product Specification - Page 89

Intel® Server Board X38ML Platform Management 5.20.3 Factory Default Event Filters 20 PEF table entries are supported. The following table describes 12 factory-pre-configured event filters. The remaining 8 entries are software... (security violation) Power supply failure BIOS BIOS: POST code error Not Supported Reserved (no source... is provided with the BMC firmware to aide an SNMP browser ...
Product Specification - Page 100

... UNDI driver for the installed network interface card must be loaded. The UNDI driver should be included with the network interface card. The Simple Network Protocol driver is available at http://developer.intel.com/technology/framework. The BIOS supports legacy PXE option ROMs in legacy mode and includes the necessary PXE ROMs in the BIOS image for the onboard controllers. The legacy PXE ROM is...
Product Specification - Page 104

...Reporting and Handling Intel® Server Board X38ML the BMC as PCI Express* Bus Correctable errors. PCI Express* non-fatal and fatal errors are reported to the BMC as PCI Express* Bus Uncorrectable errors. The system event log for these errors includes the location of the device reporting an error, the PCI Express* link number, PCI bus number, PCI device number, and the PCI function number. An...
Product Specification - Page 108

Error Reporting and Handling Intel® Server Board X38ML Field Sensor Type Sensor Number Type Code Event Data 1 Event Data 2 Event Data 3 IPMI Definition See the Intelligent Platform Management Interface Specification, Version 2.0. The number of the sensor that generated this event. 0x6F if event offsets are specific to the sensor. 7:6 00 = Unspecified byte 2 10 = OEM code in...
Product Specification - Page 109

Intel® Server Board X38ML Error... a firmware update. 6.3 Error Messages and Error Codes The system BIOS displays POST error codes and error messages on the video screen. Before video initialization, POST error codes...set in the upper and lower nibbles then both red and green LEDs are lit, resulting in an amber color. If both bits are clear, then the LED is off. In the following example, the BIOS...
Product Specification - Page 112

Error Reporting and Handling Intel® Server Board X38ML Diagnostic LED Decoder Checkpoint G=Green, R=Red, A=Amber MSB LSB Boot Device Selection 0xD0 R R OFF R Description Trying boot device selection 0xD1 R R OFF A Trying boot device selection 0xD2 R R G R Trying boot device selection 0xD3 R R G A Trying boot device selection 0xD4 R A OFF R Trying boot device ...
Product Specification - Page 115

... software state error Processor component encountered a low voltage error Processor component encountered a high voltage error PCI component encountered a SERR error ATA/ATAPI ATA bus SMART not supported ATA/ATAPI ATA SMART is disabled PCI Express* component encountered a PERR error PCI Express* component encountered a SERR error PCI Express* IBIST error DXE boot services driver not enough memory...
Product Specification - Page 123

Intel® Server Board X38ML Connectors and Jumper Blocks 7.8 Jumper Blocks The server board has several jumper blocks used to configure or enable/disable various features. This section describes the usage and settings of each jumper block. Table 65. Jumper Block Definitions (J1A2, J1A3, J1A4, J3A1, J6B1) Reference ID J1A3 J1A2 J6B1 J3A1 J1A4 Name CMOS Clear BIOS Recovery Mode...
Get Help Online

Get immediate support for your Intel X38ML questions from HelpOwl.com.

Recent Intel X38ML-related questions:

Intel Manuals

Find free Intel X38ML - Server Board Motherboard manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.