HP 2000sa driver and firmware

Drivers and firmware downloads for this Hewlett-Packard item

We have a direct link to download HP 2000sa drivers, firmware and other resources directly from the HP site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

2000sa driver download page on the HP site

Related HP 2000sa Manual Pages

Download the free PDF manual for HP 2000sa and other HP manuals at ManualOwl.com

HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 15

... interface. • FTP Access. Allows access to the file transfer protocol interface, which provides a way to install firmware updates and download logs. • Base Preference. The base for entry and display of storage-space sizes. In base 2, sizes are shown as powers of 2, using 1024 as a divisor for each magnitude. In base 10, sizes are shown as...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 59

... with the storage system. Updating controller module firmware A controller enclosure can contain one or two controller modules. In a dual-controller system, both controllers should run the same firmware version. You can update the firmware in each controller module by loading a firmware file obtained from the HP web download site, http://www.hp.com/go/msa. To install an HP ROM Flash Component or...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 60

... If you updated firmware in an HP MSA70 drive enclosure, power cycle the enclosure to complete the update process. 8. Verify that the proper firmware version appears for each updated expansion module. Updating disk firmware You can update disk firmware by loading a firmware file obtained from HP web download site, http://www.hp.com/go/msa, or from the disk manufacturer. To install an HP ROM Flash...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 107

... target controllerController environment (including data about attached disks, enclosures, and so forth) It is recommended to use a command-line-based FTP client. A GUI-based FTP client might not work. To download logs to a file 1. In SMU, prepare to use FTP: a. Determine the network-port IP addresses of the system's controllers. b. Verify that the system's FTP service is...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 108

.... If Partner Firmware Update is disabled, after updating software on one controller you must manually update the partner controller. To update controller module firmware 1. Obtain the appropriate firmware file and download it to your computer or network. 2. In SMU, prepare to use FTP: a. Determine the network-port IP addresses of the system's controllers. b. Verify that the system's FTP service is...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 109

... from the HP web download site, http://www.hp.com/go/msa. To install an HP ROM Flash Component or firmware Smart Component, follow the instructions on the HP web site; otherwise, to install a firmware binary file, follow the steps below. To update expansion module firmware 1. Obtain the appropriate firmware file and download it to your computer or network. 2. In SMU, determine the address of each...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 110

... firmware You can update disk firmware by loading a firmware file obtained from the HP web download site, http://www.hp.com/go/msa, or from the disk manufacturer. To install an HP ROM Flash Component or firmware Smart Component, follow the instructions on the HP web site; otherwise, to install a firmware binary file, follow the steps below. A dual-ported disk can be updated from either controller...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 111

6. Quit the FTP session. 7. If the updated disks must be power cycled: a. Shut down both controllers by using SMU. b. Power cycle all enclosures as described in your product's user guide. NOTE: If you loaded firmware to a Seagate 750-Gbyte Barracuda ES SATA drive, after spin-up it will be busy for about 50 seconds completing its upgrade. Then it will be ready...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 116

using WBI to update expansion module 59 versions 68 firmware update, partner configuring 41 FTP downloading system logs 107 updating controller module firmware 108 updating disk drive firmware 110 updating expansion module firmware 109 G global spare 16 global spares adding and removing 48 H hardware versions 68 help displaying online 15 obtaining 12 using the help window 15 host adding 56 ...
HP StorageWorks 2312sa and 2324sa Modular Smart Array user guide (488320-003, June 2009) - Page 31

...Linux Software with Linux servers. To download the appropriate device mapper multi-path enablement kit for your specific enterprise Linux operating system, go to http://www.hp.com/go/devicemapper. • To prevent Microsoft Windows 2003 data hosts from displaying the Found New Hardware Wizard when the storage system is discovered, install the 2000sa G2 Modular Smart Array SCSI Enclosure Services...
HP StorageWorks 2312sa and 2324sa Modular Smart Array user guide (488320-003, June 2009) - Page 35

... View > Overview. Expansion module A's firmware version is shown as EMP A Revision; expansion module B's firmware version is shown as EMP B Revision. For software and firmware updates, including update instructions, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support. Selecting an appropriate time to perform the online upgrade To ensure the success of an...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 11

... Setup Poster • HP StorageWorks 600 Modular Disk System User GuideHP StorageWorks 600 Modular Disk System Maintenance and Service Guide MSA2000sa storage enclosures: • HP StorageWorks 2000 Modular Smart Array Racking InstructionsHP StorageWorks 2000 Modular Smart Array Family Installation Road Map • HP StorageWorks 2000sa Modular Smart Array Supported Cable...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 29

... information and instructions for updating firmware on MSA controller modules. • HP StorageWorks 2000 Modular Smart Array troubleshooting guide-Includes troubleshooting information. Important tips • If needed, upgrade the MSA2000sa G2 controllers to the latest firmware version before connecting to the switch. • For high availability, two controllers must be installed in each...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 32

...-Includes information and instructions for updating firmware on MSA2000sa controllers. • HP StorageWorks 2000 Modular Smart Array troubleshooting guide-Includes troubleshooting information. Important tips • Be sure to upgrade the MSA2000sa controllers to the latest firmware version before connecting to the switch. • For high availability, two controllers must be installed in each...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 56

... supported. ◦ Be sure to obtain the .fuf file download from the HP website (not the .SCEXE file). The .fuf file is used when updating the MDS600 using the VSM. ◦ Before installing the firmware, all blade servers with access to the MDS600 must be powered off. If the servers are powered on, the Update Storage Enclosure Firmware task is not displayed...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 61

..., proceed to the next step. For detailed instructions on installing MDS600 storage enclosures, see "Setup" in the HP StorageWorks 600 Modular Disk System User Guide. a. Before installing each MDS600 storage enclosure, record important device information in "MDS600 storage enclosure worksheet" (page 69). b. Determine the currently-installed firmware version and record it in the provided spaces in...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 62

.... For more information on updating firmware on the MDS600, see "Updating firmware on MDS600 disk enclosures" (page 76). 8. Install MSA2000sa controller enclosures and MSA drive enclosures. If not included in your solution, proceed to the next step. For detailed instructions on installing MSA storage enclosures, see "Installing and Cabling Enclosures" in the user guide for your MSA2000sa model...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 63

i. If needed, upgrade the firmware on the MSA2000 controllers, using the SMU interface and the firmware obtained in Step 8.c. For more information on updating MSA2000 storage enclosures, see "Updating firmware on MSA2000sa controller and drive enclosures" (page 77). j. Install required MSA-specific drivers and software, such as the multipathing Device Specific Module, on each server that will ...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 76

..., close the maintenance window and do the following: a. Restart storage enclosures. b. Restart server blades. c. Restart I/O. Updating firmware on MDS600 disk enclosures When the MDS600 is directly cabled to an HP 3Gb SAS BL Switch in a BladeSystem solution, firmware must be updated using a downloaded .fuf firmware image file package and the HP Virtual SAS Manager (VSM) software utility. IMPORTANT...
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide - Page 77

...A Revision; expansion module B's firmware version is shown as EMP B Revision. To obtain software and firmware downloads, including SmartComponent update instructions, go to the Hp Support Downloads page: http://www.hp.com/support/downloads. Before beginning, select an appropriate time for the update: • In single-controller configurations, schedule a maintenance window to stop all I/O. •...
Get Help Online

Get immediate support for your HP 2000sa questions from HelpOwl.com.

Recent HP 2000sa-related questions:

HP Manuals

Find free HP 2000sa manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the HP corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.