HP Cluster Platform Cabling Tables v2010 driver and firmware

Drivers and firmware downloads for this Hewlett-Packard item

We have a direct link to download HP Cluster Platform Cabling Tables v2010 drivers, firmware and other resources directly from the HP site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

Cluster Platform Cabling Tables v2010 driver download page on the HP site

Related HP Cluster Platform Cabling Tables v2010 Manual Pages

Download the free PDF manual for HP Cluster Platform Cabling Tables v2010 and other HP manuals at ManualOwl.com

HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 1

... an overview of the core infrastructure components for all HP Cluster Platform models and associated platforms for experienced hardware administrators of large-scale computer systems and for HP Global Service representatives. This guide refers to the original component documentation, which should be available during installation, configuration, and maintenance operations. Part Number: 614066-002...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 4

Support and other resources ...85 Technical support ...85 Contacting HP...85 Documentation feedback ...85 Related documentation...86 Cluster component documentation 86 HP Cluster Platform documentation 86 Bracket installation guides ...87 Important safety information...87 Typographic conventions...87 Acronyms and abbreviations...89 Index...91 Contents 4
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 5

... are not supported in HP Cluster Platform configurations. For more information, contact an HP representative. Processor Intel® Xeon® AMD Opteron Supported server HP ProLiant DL160 G6 Server HP ProLiant DL170e G6 Server HP ProLiant DL170h G6 Server HP ProLiant DL380 G6 Server HP ProLiant DL380 G7 Server HP ProLiant SL170s G6 Server HP ProLiant SL2x170z G6 Server HP ProLiant SL390s...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 6

... rear views • InfiniBand HCA PCI slot assignment • Specific cable management instructions, if necessary • HP Cluster Platform specific maintenance instructions, if applicable HP ProLiant DL160 G6 Server The HP ProLiant DL160 G6 Server is used as a control node, a utility node, and a compute node in HP Cluster Platform configurations. HP ProLiant DL160 G6 Server documentation For...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 9

... = LAN is linking. Flashing green = LAN is active. Off = No connection Blue = Identification Flashing blue = System is being managed remotely. Off = Off Green = LAN is linking. Flashing green = LAN is active. Off = No connection Green = Linking at 100 Mbps speed Off = No connection or linking at 10 Mbps speed PCI expansion slot definitions (DL160 G6) Always install an InfiniBand PCIe HCA...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 12

...compute node in HP Cluster Platform configurations. HP ProLiant DL170e G6 Server documentation For server-specific information, see the server documentation: • For a complete list of features and specifications, see the HP ProLiant DL2000 Multi Node Server QuickSpecs on the HP website (http://h18004.www1.hp.com/products/quickspecs/13847_na/13847_na.html). • For installation and service...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 19

... and Service Guide on the HP website (http://www.hp.com/support/manuals). Under servers, select ProLiant ML/DL and TC series servers, and then select HP ProLiant DL380 G6 Server series. Front panel components (DL380 G6) • SFF hard drive model Item 1 2 3 4 5 6 Description Quick release levers (2) Systems Insight Display Hard drive bays (8) SATA optical drive bay Video connector USB...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 22

... is off or power supply has failed UID LED/button Blue = Activated Flashing blue = System being managed remotely Off = Deactivated NIC/iLO 2 activity Green = Network activity LED Flashing green = Network activity Off = No network activity NIC/iLO 2 link LED Green = Network link Off = No network link PCI expansion slot definitions (DL380 G6) Always install an InfiniBand PCIe HCA in slot...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 23

• The PCIe x16 riser supports a maximum power of 150W with an HP power cable. The cable supplied with the riser must be used for PCIe card wattages greater than 75W. HP ProLiant DL380 G7 Server The HP ProLiant DL380 G7 Server is used as a control node in HP Cluster Platform configurations. HP ProLiant DL380 G7 Server documentation For server-specific information, see the server ...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 27

...Opteron servers: • Front and rear views • InfiniBand HCA PCI slot assignment • Specific cable management instructions, if necessary • HP Cluster Platform specific maintenance instructions, if applicable HP ProLiant DL165 G6 Server The HP ProLiant DL165 G6 Server is used as a control node and a compute node in HP Cluster Platform configurations. HP ProLiant servers (rack) 27
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 28

... the HP ProLiant DL100 Series Server User Guide and the HP ProLiant DL165 G6 Server Maintenance and Service Guide on the HP website (http://www.hp.com/support/manuals). Under servers, select ProLiant ML/DL and TC series servers, and then select HP ProLiant DL165 G6 Server series. Front panel components (DL165 G6) Item Description 1 Optical drive 2 Serial label pull tab 3 Front USB connector...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 31

... Low-profile Low-profile Connector Width x16 - x8 - Bus Width x16 - x4 64-bit, 133 MHz Always install an InfiniBand PCIe HCA in slot 1 of this server. HP ProLiant DL165 G7 Server The ProLiant DL165 G7 Server is used as a control node and a compute node in HP Cluster Platform configurations. HP ProLiant DL165 G7 Server documentation For server-specific information...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 35

... only be populated with a half-length, full-height form factor expansion board. Always install an InfiniBand PCIe HCA in slot 1 of this server. HP ProLiant DL385 G6 Server The HP ProLiant DL385 G6 Server is used as a control node and utility node in HP Cluster Platform configurations. HP ProLiant DL385 G6 Server documentation For server-specific information, see the server...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 36

... Maintenance and Service Guide on the HP website (http://www.hp.com/support/manuals). Under servers, select ProLiant ML/DL and TC series servers, and then select HP ProLiant DL385 G6 Server series. Front panel components (DL385 G6) Item 1 2 3 4 5 6 7 Description Serial number label Systems Insight Display Video connector USB connectors (2) Hard drive bays SATA optical drive bay Quick release...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 38

... activity iLO 2 link LED* Green = Network link Off = No network link NIC link LED Green = Network link Off = No network link iLO 2 activity LED* Green = Network activity Flashing green = Network activity Off = No network activity * iLO 2 LED positions are reversed from the embedded NIC LEDs PCI expansion slot definitions (DL385 G6) Always install an InfiniBand PCIe HCA in slot 4 of this...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 39

..., full-height. LP denotes low profile. • The PCIe x16 riser supports a maximum power of 225W with an HP power cable. This cable must be used for PCIe card wattages greater than 75W. HP ProLiant DL385 G7 Server The HP ProLiant DL385 G7 Server is used as a control node and utility node in HP Cluster Platform configurations. HP ProLiant DL385 G7 Server documentation For server-specific...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 42

.... LP denotes low profile. • The PCIe2 x16 riser supports a maximum power of 225W with an HP power cable. This cable must be used for PCIe card wattages greater than 75W. HP ProLiant DL585 G6 Server The HP ProLiant DL585 G6 Server is used as a control node, utility node, or compute node in HP Cluster Platform configurations. HP ProLiant DL585 G6 Server documentation For server-specific...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 46

... LED LED color Blue Green Green Status On = Activated Flashing = Server remotely managed Off = Deactivated On or flashing = Network activity Off = No network activity On = Linked to network Off = Not linked to network PCI expansion slot definitions (DL585 G6) Always install an InfiniBand PCIe HCA in slot 7 of this server. Slot Description 1 PCI-X non-hot-plug expansion slot, 64-bit/100...
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 48

.... The figure describes the front panel components for one of eight SL170s servers in the s6500 chassis. Item 1 2 3 4 5 6 7 8 9 10 Description Front PCIe bracket (LP slot) Video connector Serial connector UID LED Health LED Power LED 1 GbE NIC 1 LAN Port 1 GbE NIC 2 LAN Port/Shared Management port USB 2.0 port (2) Dedicated Management Port (IPMI) (optional) HP ProLiant servers (scalable) 48
HP Cluster Platform ProLiant G6 and G7 Server Overview - Page 85

... information available before you call HP: • Technical support registration number (if applicable) • Product serial number • Product model name and number • Product identification number • Applicable error messages • Add-on boards or hardware • Third-party hardware or software • Operating system type and revision level HP contact information For the...
Get Help Online

Get immediate support for your HP Cluster Platform Cabling Tables v2010 questions from HelpOwl.com.

Recent HP Cluster Platform Cabling Tables v2010-related questions:

HP Manuals

Find free HP Cluster Platform Cabling Tables v2010 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the HP corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.