HP Surestore FC10 - Disk Array driver and firmware
Drivers and firmware downloads for this Hewlett-Packard item
Related HP Surestore FC10 Manual Pages
Download the free PDF manual for HP Surestore FC10 and other HP manuals at ManualOwl.com
ISS Technology Update, Volume 9 Number 1 - Page 1
...HP Power Supply Technology
http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf
HP ProLiant 100-series Intel-based G6 server technology, 3rd edition
http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf
HP Smart Array Controller technology, 3rd edition
http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf
Using HP ProLiant Network Teaming Software with Microsoft® Windows...
ISS Technology Update, Volume 9 Number 1 - Page 2
ISS Technology Update
Volume 9, Number 1
How many bytes are in a GB?
Storage device manufacturers and operating system developers answer this question differently. This is the reason why a number of lawsuits have sprung up around the country, typically between storage device manufacturers and disgruntled customers. For example, the capacity of a 300,000,000,000 byte drive is reported as...
ISS Technology Update, Volume 9 Number 1 - Page 3
ISS Technology Update
Volume 9, Number 1
edition, Letter symbols to be used in electrical technology - Part 2: Telecommunications...sizes to powers of ten.
For memory capacities, binary prefixes are more natural. For example, reporting a Smart Array controller cache size of 512 MiB is preferable to reporting it as 536.9 MB.
HP is considering modifying its storage utilities to report disk capacity ...
ISS Technology Update, Volume 9 Number 1 - Page 4
... Table 1). The option to enable only one core is not present in the currently released BIOS updates.
HP Note The lack of support for single-core operation is based on observations with Systems ROMPaq Firmware Upgrade for HP ProLiant DL385 G5 (A09) Servers Version: 2009.07.11 (A) (11 Sep 2009).
AMD Core Select technology
AMD Core Select is...
ISS Technology Update, Volume 9 Number 1 - Page 5
... on the system during the operating system installation as follows:
- When installing to disks attached to a Smart Array controller, the miniroot must have the array driver so that the Solaris software can be installed onto the disks. See the deployment guide for information on installing the Smart Array driver, cpqary3, into the miniroot.
- For network-based deployments, the miniroot must have...
ISS Technology Update, Volume 9 Number 1 - Page 6
... in over 200 standards organizations through more than 500 technical committees. HP engineers help develop specifications for memory, wired and wireless telecommunications, storage, management software, information technology and security, ANSI, IEEE, ISO/IEC, and so forth. HP also works closely with industry partners that develop processors, memory, storage, and networking components.
6
ISS Technology Update, Volume 9 Number 1 - Page 7
... only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. AMD and AMD Opteron are trademarks of Advanced Micro Devices, Inc. Intel, Intel...
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 35
Installation
2
INSTALLATION
Electrical Preparation Tools Step 1: Unpack the Product Step 2A: Install Rails (for Legacy Racks) Step 2B: Install Rails (for System/E Racks) Step 3: Prepare Rack Front Step 4: Mount the Disk System Step 5: Install GBICs and LCCs Step 6: Set the Enclosure ID Step 7: Connect Fiber Optic and Power Cables Step 8: Install Disks and Fillers Step 9: Turn on the Disk System...
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 39
No. of Disk Systems 1.25 meter (25 U)
1 - 4 5 - 8 9 - 11
2 19-inch/16-amp PDUs NA** NA**
1.6 meter (33 U)
2.0 meter (41 U)
2 19-inch/30-amp PDRUs*
2 19-inch/30-amp PDRUs*
NA**
4 19-inch/30-amp PDRUs
Installation
39
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 41
Installation
30-amp PDRU
30-amp PDRU
41
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 44
Figure Label Part (part number)
A Disk system chassis with pre-installed fans and power supplies B Two power cords (8120-6514)
44
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 48
Step 2B: Install Rails (for System/E Racks)
Figure Label Part
A 2 rails B 2 rail clamps C 14 M5 16mm screws D 10 sheet metal nuts E Rack Mount Guide and Template
48
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 57
Installation
Caution To protect the door, do not lift or move the disk system with the door open.
57
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 61
Installation
Note Caution Do not touch the pins on the back of the LCC. Note
61
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 63
Installation
Step 7: Connect Fiber Optic and Power Cables
Note
63
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 65
Installation
30A PDRU
A A A A AC IN B B B B
30A PDRU
C C C C AC IN D D D D
Disk Systems AE AF AG BE BF BH CF CG CH DG DH
30A PDRU
E E E E AC IN F F F F
30A PDRU
G G G G AC IN H H H H
65
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 71
3
Viewing a Disk System in IOSCAN Setting Up the Hardware Event Monitor Annotating Devices Updating Firmware (HP-Qualified Only)
CONFIGURATION
Configuration
71
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 80
Updating Firmware (HP-Qualified Only)
80
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 96
...and LCC B have different firmware versions.
Sensors
Voltage/temperature exceeds warning limit.
Not Installed
All replaceable components Component is not installed. and sensors
Unknown
Sensors
Sensor has failed or status is not available.
Not Available
All replaceable components Component is installed without known errors, but
and sensors
has not been turned on or set into operation.
96
Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide - Page 101
... Probable Cause/Solution
IOSCAN lists disks and LCC controller as NO_HW
Critical
IOSCAN lists none a disk device as NO_HW
Rx Rdy none off
all
none
normal
Power LED on; Fault LED off
Not Available
none
- Fibre Channel cable is unplugged or loose at either end.
- Fibre Channel cable is damaged. Replace with another cable to test.
- Prior units...