Asus AP2300 driver and firmware

Drivers and firmware downloads for this Asus item

We have a direct link to download Asus AP2300 drivers, firmware and other resources directly from the Asus site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

AP2300 driver download page on the Asus site

Related Asus AP2300 Manual Pages

Download the free PDF manual for Asus AP2300 and other Asus manuals at ManualOwl.com

AP2300 Server in English - Page 2

... are released for each product design represented by the digit before and after the period of the manual revision number. Manual updates are represented by the third digit in the manual revision number. For previous or updated manuals, BIOS, drivers, or product release information, contact ASUS at http://www.asus.com.tw or through any of the means indicated on the following...
AP2300 Server in English - Page 4

... 18 Fan Modules 18 4-2 Rear Cooling Fan Control Board 19 Rear Cooling Fan Control Board Settings 19 4-3 Motherboard Placement 20 Motherboard Spacers 20 Motherboard Screws 20 Chassis Intrusion Connector 20 Device Cables 21 Cable Connections 21 4-4 Central Processing Unit (CPU 22 Installing S370 CPU 22 4-5 Fan Heatsink 23 Fan Heatsink Attachment 23 4 AP2300 Hardware Reference Guide
AP2300 Server in English - Page 6

...expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Canadian Department of Communications Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. 6 AP2300 Hardware Reference Guide
AP2300 Server in English - Page 7

... MUST be followed in order to complete a task. NOTE: Tips and information to aid in completing a task. PHILIP (CROSS) SCREW DRIVER: Tools required to install or remove the components in this server. STANDARD (FLAT) SCREW DRIVER: Tools required to install or remove the components in this server. STEP: Actions to complete a task. AP2300 Hardware Reference Guide 7
AP2300 Server in English - Page 10

.... • When the server is powered on, heat sinks and the surfaces of certain IC devices may be hot. Do not touch them. Check whether the fans are functioning properly. Tools Required A Phillips (cross) screwdriver and a standard (flat) screwdriver are needed to install or remove the components in this server. 10 AP2300 Hardware Reference Guide
AP2300 Server in English - Page 11

... electrical potentials. CAUTION This product is equipped with a three-wire power cable and plug for the user's safety. Use the power cable in conjunction with a properly grounded electrical outlet to avoid electrical shock. IMPORTANT Motherboards, adapters, and disk drives are sensitive to static electricity discharge. These devices are wrapped in antistatic bags to prevent this damage. Take the...
AP2300 Server in English - Page 16

... the system is booted, the power LED is green. When the hard drive is being accessed, the hard drive access LED is green. Power LED Power Button Hard Drive Access LED LEDs • 3-3 BIOS Setup This server does not come with any pre-installed software. When booting your server for the first time, make BIOS settings by following the motherboard User's Manual. 16 AP2300 Reference Guide
AP2300 Server in English - Page 17

4. Hardware Setup This section gives descriptions of how to install and remove components. When setting up devices on the server, perform the following steps. • 4-1 Opening the Chassis Panel Screws The top panel on the ...with your fingers. Removing the Front Door Push down on the hinge spring to remove the front door. 4. Hardware Setup Opening the Chassis AP2300 Hardware Reference Guide 17
AP2300 Server in English - Page 19

... when connected to the control board. The ASMA software can monitor the fan status from the fan control board. The fan control board's cable connections are shown below. Fan Fan Power Connectors Reserved Connector Fan Status Signal Connector Power Input Connector Fan Control Settings Reserved Fan Connectors Rear Cooling Fan Control Board Settings The rear fan control board has DIP switches to...
AP2300 Server in English - Page 20

... Hardware Setup • 4-3 Motherboard Placement You can remove the extended expansion card guide before installing or removing the motherboard. All screws are necessary to provide the needed stabilization to support all the motherboard expansion cards used in this chassis. Motherboard Spacers Place four spacers in the areas circled on the chassis. Extended Expansion Card Guide Spacer Motherboard...
AP2300 Server in English - Page 22

... have a fan heatsink attached to it to prevent overheating. When only one processor is used, the other S370 connector can be terminated with the optional S370 terminator to improve signaling. For memory installation, refer to the motherboard User's Manual. 4. Hardware Setup CPU Installing S370 CPU Locate the ZIF socket and open it by first pulling the lever sideways away...
AP2300 Server in English - Page 23

... CPU. CPU Fan Power Fan Heatsink Clip Fan Heatsink Attachment To install the fan heatsink, first align the fan heatsink over the mounted CPU. Attach the heatsink clip over the clip attach point as shown above. Connect the fan power plug to the motherboard. To remove the fan heatsink, reverse the installation procedure. 4. Hardware Setup Fan Heatsink AP2300 Hardware Reference Guide...
AP2300 Server in English - Page 24

... chassis intrusion detection to work. The motherboard will signal the ASMA software when the side panel is opened. The connection diagram is given here. 4. Hardware Setup Chassis Intrusion Switch Cable Chassis Intrusion Switches (one on each side) from the two Chassis Intrusion Switches Motherboard's Chassis Intrusion Lead (No Connection) GND Chasis Signal 24 AP2300 Hardware Reference Guide
AP2300 Server in English - Page 25

4. Hardware Setup • 4-7 Expansion Cards Expansion cards can be easily installed just like on any standard PC. Up to 7 PCI cards can be installed. 4. Hardware Setup Expansion Cards Contact CAUTION Make sure that the total amperage of your installed expansion cards does not exceed the system power specification. AP2300 Hardware Reference Guide 25
AP2300 Server in English - Page 27

... the cover away from the chassis using a screw driver from the front. Storage Device Spacers A floppy drive spacer is used to cover the floppy drive and power button. A standard storage device spacer is used to cover the CDROM, tape drive, or additional CD-ROMs. You should purchase an extra spacer for each storage device. Floppy Drive Spacer Fixed Device Spacer AP2300 Hardware Reference Guide 27
AP2300 Server in English - Page 29

... Setup Hot-Swap Bay Hot-Swap Bay To remove the hot-swap bay, release the front cooling fans first by pressing the eject mechanism with a small screwdriver. Remove the six retaining screws as circled above and then the entire hot-swap bay can be slid out of the chassis. AP2300 Hardware Reference Guide...
AP2300 Server in English - Page 30

... by four screws on each fan. The ASMA (ASUS Server Management Agent) software will report an error message when any of these two fans malfunctions. Front Cooling Fan Control Board (mounted with the component side facedown) ß,§, Lower Fan Upper Fan 4. Hardware Setup Front Cooling Fans Hard Disk Drive Message Board (LEDs) IMPORTANT Usually, the rotation of the...
AP2300 Server in English - Page 31

4. Hardware Setup Connects to the SCSI Back plane Board 4. Hardware Setup Front Cooling Fans 8 16 3-pin Fan Header Pin 1 3-pin Fan Header 1 LED Board Header 9 (connects to the LED board through a ribbon cable) Front Cooling Fan Control Board A cable connects the front cooling fan control board and the hard disk drive message board. Orient the red markings on each end of the cable to pin 1....
AP2300 Server in English - Page 33

... Tray2 02 Tray1 00 Bottom Bay NOTE All SCSI devices must have a SCSI identification number that is not in use by any other SCSI device. SCSI devices vary in how they set the ID number. Refer to the product manual for any additional devices that you may install for details on how to set its ID number. 4. Hardware Setup SCSI ID Setting AP2300 Hardware Reference Guide 33
AP2300 Server in English - Page 42

..., whereas male connectors are found on twisted pair cabling used to connect two networking devices. SCA (Single Connector Attachment) SCA is a technology that incorporates both power and signal into an 80-pin interface. The SCA interface is designed to facilitate hardware installation and to support hot-swapping. SCSI (Small Computer System Interface) High speed parallel interface defined by...
Get Help Online

Get immediate support for your Asus AP2300 questions from HelpOwl.com.

Recent Asus AP2300-related questions:

  • Tb_header Hd Audio Location
    I'm trying to add a Thunderbolt Expansion Card but can't seem to find the TB_Header. The manual for ...
  • 8-pin Eatx12v1
    How do I connect the 8-pin EATX12V1 for CPUs 95W or less? I cannot get the board to boot and I belie...
  • B0 Q-code
    Server stucks with code b0. Processor i7-4930K. VGA port gives No signal. It is first boot. Can abyb...

Asus Manuals

Find free Asus AP2300 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Asus corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Asus customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings