FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 27
...8226; boot config • boot host • boot network • boot system • boot system gateway • cd • change bootflash-image • copy • copy (Streamline Upgrade) • copy running-config startup-config • delete • dir • download alt-boot-image • download alt-full-image • download alt-system-image • format (C-Series and E-Series...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 34
... Server
Force10#copy scp: flash: Address or name of remote host []: 10.11.199.134 Port number of the server [22]: 99 Source file name []: test.cfg User name to login remote host: admin Password to login remote host: Destination file name [test.cfg]: test1.cfg
Related
Commands
cd
Change working directory.
copy (Streamline Upgrade)
c e Copy a system image to a local file and update...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 36
... Privilege
Command History
Version 7.6.1.0
Introduced on S-Series
Version 7.5.1.0
Introduced on C-Series
E-Series original Command
Example
Command Example dir for the Internal Flash
Force10#dir Directory of flash:
1 -rwx 6478482 May 13 101 16:54:34 E1200.BIN
flash: 64077824 bytes total (57454592 bytes free) Force10#
Related
Commands
cd
Change working directory.
download alt-boot-image...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 37
...of this command are incorporated into the upgrade Information command.
For software upgrade details, see the FTOS Release Notes.
Related Commands
upgrade (E-Series version)
Upgrade the bootflash or boot selector versions
download alt-system-image
e Download an alternate system image (not the boot flash or boot selector image) to the chassis.
Syntax download alt-system-image file-url
Command...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 52
.../work/sw/build/build2/Release/E7-8-1/SW/SRC Force10 uptime is 1 minute(s) System Type: S50V Control Processor: MPC8451E with 252739584 bytes of memory.
32M bytes of boot flash memory.
1 48-port E/FE/GE with POE (SB) 48 GigabitEthernet/IEEE 802.3 interface(s)
4 Ten GigabitEthernet/IEEE 802.3 interface(s) Force10#
upgrade (E-Series version)
e Upgrade the bootflash, boot selector, or system image on...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1437
clock update-calendar
c e s Set the switch hardware clock based on the software clock.
Syntax clock update-calendar
Defaults Not configured.
Command Modes EXEC Privilege
Command History
Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0
Support added for S-Series Support added for C-Series Introduced for E-Series
Usage Use this command only if you are sure that the hardware clock is ...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1520
... technical support representative instructs you to do so.
Layer 2 Debug Command
show software macagent
c This command displays tables and advanced debugging information related to the MAC Agent
process.
Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number
Parameters
configs mac-addr...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 397
.... The failover type is hot failover. FTOS displays Message 2.
Message 2 FTOS Version Incompatibility Error
*
*
Warning !!! Warning !!! Warning !!!
*
*
*
Incompatible SW Version detected !!
*
*
This RPM -> 7.4.2.0
*
Peer RPM -> 7.4.1.0
*
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 412
...is not present.
Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress
cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area
Upgrade result
All cache boot image upgraded to 4.7.5.427 Force10#
View your cache boot configuration using...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 527
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 36
... to the chassis.
Syntax download alt-boot-image file-url
Command Modes EXEC Privilege
Command History
Version 7.7.1.0
Removed from E-Series and C-Series
Version 7.5.1.0
Introduced on C-Series
E-Series original Command
Usage Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade Information command.
For software upgrade details, see the FTOS Release...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 37
...of this command are incorporated into the upgrade Information command.
For software upgrade details, see the FTOS Release Notes.
Related Commands
upgrade (E-Series version)
Upgrade the bootflash or boot selector versions
download alt-system-image
e Download an alternate system image (not the boot flash or boot selector image) to the chassis.
Syntax download alt-system-image file-url
Command...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1435
clock update-calendar
c e s Set the switch hardware clock based on the software clock.
Syntax clock update-calendar
Defaults Not configured.
Command Modes EXEC Privilege
Command History
Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0
Support added for S-Series Support added for C-Series Introduced for E-Series
Usage Use this command only if you are sure that the hardware clock is ...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1518
... technical support representative instructs you to do so.
Layer 2 Debug Command
show software macagent
c This command displays tables and advanced debugging information related to the MAC Agent
process.
Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number
Parameters
configs mac-addr...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 381
.... The failover type is hot failover. FTOS displays Message 2.
Message 2 FTOS Version Incompatibility Error
*
*
Warning !!! Warning !!! Warning !!!
*
*
*
Incompatible SW Version detected !!
*
*
This RPM -> 7.4.2.0
*
Peer RPM -> 7.4.1.0
*
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 396
... 5 is not present.
Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress
cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area
Upgrade result
All cache boot image upgraded to 4.7.5.427 FTOS#
View your cache boot configuration...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
Installing S50N and S50V Systems - Page 42
www.dell.com | support.dell.com
Step
Task (continued)
4
If you use the console port to download software to the switch, you should raise the console baud rate. If SFTOS
is installed, establish a connection with the default settings to verify the connection. Then use the lineconfig
command to access the Line Config mode, and use the serial baudrate command to...
Installing S50N and S50V Systems - Page 56
... Dell Force10 TAC Information to Submit When Opening a Support Case
Managing Your Case Downloading Software Updates Technical Documentation Contact Information
Log in to iSupport at http://www.force10networks.com/support/, and select the Service Request tab. • Your name, company name, phone number, and E-mail address • Preferred method of contact • Model number • Serial...
Quick Start Guide for the S50N and S50V Systems - Page 5
... running and ready for configuration. For complete installation and configuration information, refer to the following documents:
Documentation Hardware installation and power-up instructions Software configuration Command line interface Latest updates
S50N/S50V Installing S50N and S50V Systems
FTOS Configuration Guide FTOS Command Line Reference Guide Release Notes for the S-Series