Dell Force10 S50-01-GE-48T driver and firmware

Drivers and firmware downloads for this Dell item

We have a direct link to download Dell Force10 S50-01-GE-48T drivers, firmware and other resources directly from the Dell site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

Force10 S50-01-GE-48T driver download page on the Dell site

Related Dell Force10 S50-01-GE-48T Manual Pages

Download the free PDF manual for Dell Force10 S50-01-GE-48T and other Dell manuals at ManualOwl.com

FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 27

...8226; boot config • boot host • boot network • boot system • boot system gateway • cd • change bootflash-image • copycopy (Streamline Upgrade) • copy running-config startup-config • delete • dir • download alt-boot-image • download alt-full-image • download alt-system-image • format (C-Series and E-Series...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 34

... Server Force10#copy scp: flash: Address or name of remote host []: 10.11.199.134 Port number of the server [22]: 99 Source file name []: test.cfg User name to login remote host: admin Password to login remote host: Destination file name [test.cfg]: test1.cfg Related Commands cd Change working directory. copy (Streamline Upgrade) c e Copy a system image to a local file and update...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 36

... Privilege Command History Version 7.6.1.0 Introduced on S-Series Version 7.5.1.0 Introduced on C-Series E-Series original Command Example Command Example dir for the Internal Flash Force10#dir Directory of flash: 1 -rwx 6478482 May 13 101 16:54:34 E1200.BIN flash: 64077824 bytes total (57454592 bytes free) Force10# Related Commands cd Change working directory. download alt-boot-image...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 37

...of this command are incorporated into the upgrade Information command. For software upgrade details, see the FTOS Release Notes. Related Commands upgrade (E-Series version) Upgrade the bootflash or boot selector versions download alt-system-image e Download an alternate system image (not the boot flash or boot selector image) to the chassis. Syntax download alt-system-image file-url Command...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 52

.../work/sw/build/build2/Release/E7-8-1/SW/SRC Force10 uptime is 1 minute(s) System Type: S50V Control Processor: MPC8451E with 252739584 bytes of memory. 32M bytes of boot flash memory. 1 48-port E/FE/GE with POE (SB) 48 GigabitEthernet/IEEE 802.3 interface(s) 4 Ten GigabitEthernet/IEEE 802.3 interface(s) Force10# upgrade (E-Series version) e Upgrade the bootflash, boot selector, or system image on...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1437

clock update-calendar c e s Set the switch hardware clock based on the software clock. Syntax clock update-calendar Defaults Not configured. Command Modes EXEC Privilege Command History Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0 Support added for S-Series Support added for C-Series Introduced for E-Series Usage Use this command only if you are sure that the hardware clock is ...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1520

... technical support representative instructs you to do so. Layer 2 Debug Command show software macagent c This command displays tables and advanced debugging information related to the MAC Agent process. Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number Parameters configs mac-addr...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 397

.... The failover type is hot failover. FTOS displays Message 2. Message 2 FTOS Version Incompatibility Error * * Warning !!! Warning !!! Warning !!! * * * Incompatible SW Version detected !! * * This RPM -> 7.4.2.0 * Peer RPM -> 7.4.1.0 * 00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 412

...is not present. Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes cache boot image downloading in progress cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area Upgrade result All cache boot image upgraded to 4.7.5.427 Force10# View your cache boot configuration using...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 527

...; however, the ISO NET format is supported for addressing. To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks: • Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 36

... to the chassis. Syntax download alt-boot-image file-url Command Modes EXEC Privilege Command History Version 7.7.1.0 Removed from E-Series and C-Series Version 7.5.1.0 Introduced on C-Series E-Series original Command Usage Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade Information command. For software upgrade details, see the FTOS Release...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 37

...of this command are incorporated into the upgrade Information command. For software upgrade details, see the FTOS Release Notes. Related Commands upgrade (E-Series version) Upgrade the bootflash or boot selector versions download alt-system-image e Download an alternate system image (not the boot flash or boot selector image) to the chassis. Syntax download alt-system-image file-url Command...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1435

clock update-calendar c e s Set the switch hardware clock based on the software clock. Syntax clock update-calendar Defaults Not configured. Command Modes EXEC Privilege Command History Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0 Support added for S-Series Support added for C-Series Introduced for E-Series Usage Use this command only if you are sure that the hardware clock is ...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1518

... technical support representative instructs you to do so. Layer 2 Debug Command show software macagent c This command displays tables and advanced debugging information related to the MAC Agent process. Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number Parameters configs mac-addr...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 381

.... The failover type is hot failover. FTOS displays Message 2. Message 2 FTOS Version Incompatibility Error * * Warning !!! Warning !!! Warning !!! * * * Incompatible SW Version detected !! * * This RPM -> 7.4.2.0 * Peer RPM -> 7.4.1.0 * 00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 396

... 5 is not present. Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes cache boot image downloading in progress cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area Upgrade result All cache boot image upgraded to 4.7.5.427 FTOS# View your cache boot configuration...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511

...; however, the ISO NET format is supported for addressing. To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks: • Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
Installing S50N and S50V Systems - Page 42

www.dell.com | support.dell.com Step Task (continued) 4 If you use the console port to download software to the switch, you should raise the console baud rate. If SFTOS is installed, establish a connection with the default settings to verify the connection. Then use the lineconfig command to access the Line Config mode, and use the serial baudrate command to...
Installing S50N and S50V Systems - Page 56

... Dell Force10 TAC Information to Submit When Opening a Support Case Managing Your Case Downloading Software Updates Technical Documentation Contact Information Log in to iSupport at http://www.force10networks.com/support/, and select the Service Request tab. • Your name, company name, phone number, and E-mail address • Preferred method of contact • Model number • Serial...
Quick Start Guide for the S50N and S50V Systems - Page 5

... running and ready for configuration. For complete installation and configuration information, refer to the following documents: Documentation Hardware installation and power-up instructions Software configuration Command line interface Latest updates S50N/S50V Installing S50N and S50V Systems FTOS Configuration Guide FTOS Command Line Reference Guide Release Notes for the S-Series About this...
Get Help Online

Get immediate support for your Dell Force10 S50-01-GE-48T questions from HelpOwl.com.

Recent Dell Force10 S50-01-GE-48T-related questions:

Dell Manuals

Find free Dell Force10 S50-01-GE-48T manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Dell corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.