HP StorageWorks Simple SAN connection manager release notes (5697-0281, February 2010) - Page 3
... requirements to support SSCM and other HP software: • Microsoft Windows Server 2003 R2 x64/x86 with Service Pack 2 and Microsoft hotfix
QFE932755, available on the Microsoft website at http://support.microsoft.com/kb/932755, or the Microsoft Windows Server 2008 x64/x86 operating system with Service Pack 1 or later • 512 MB of memory • 200 MB of disk space
HP StorageWorks Simple...
HP StorageWorks SN6000 Fibre Channel Switch release notes (5697-0280, February 2010) - Page 3
...ISLs), changing switch configurations, or installing firmware. • No port in the fabric is in the diagnostic state • No zoning changes are being made in the fabric • No changes are being made to attached devices, including powering up, powering down, disconnecting, connecting and Host Bus Adapter (HBA) configuration changes
Before upgrading firmware, HP recommends that you back up...
HP StorageWorks SN6000 Fibre Channel Switch release notes (5697-0280, February 2010) - Page 4
... of an HP 8/20q Fibre Channel Switch can download HP SSCM 3.00 from HP to upgrade their SSCM software.
NOTE: Upgrades to future versions of SSCM software will be available only to customers who have purchased a software support contract for SSCM.
1. Go to the HP website http://www.software.hp.com/kiosk. 2. In the login window User name box, enter SSCM_3X_KIOSK, in the password box, enter...
HP StorageWorks H-series SN6000 Fibre Channel Switch Release Notes (5697-0416, June 2010) - Page 3
... 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide.
Upgrading SSCM
SSCM software is included with the purchase of a switch. The latest released version of SSCM is 3.10. You can download this software using the instructions, username, and password that were provided for SSCM Version 3.00.
HP StorageWorks H-series SN6000 Fibre Channel Switch Release Notes 3
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 5
... Installation upgrade wizard: Add EVA Management Account 23 8 Installation upgrade wizard: finished with errors 24 9 Installation wizard: initial window for program removal 26 10 Simple SAN Connection Manager user interface 30 11 Initialize an Enterprise Virtual Array (EVA) Storage Subsystem dialog box 35 12 New Switch Setup dialog box 36 13 Set Switch IP Address dialog box: new switch setup...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 13
... how to set the switch default zoning, admin password, IP address, Simple Network Management Protocol (SNMP) properties, symbolic name, domain ID, and domain properties.
• "Managing HBAs," page 75, provides procedures for viewing HBA information, updating the HBA Basic Input/Output System (BIOS) image and driver, creating an alias for an HBA, and manually entering Fabric Device Management...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 14
...requirements) • Windows Server 2008 • Supported Linux servers
• 512 MB of memory • Disk space:
• Full management installation-200 MB of disk space • Full non-management installation-60 MB of disk space • One 2.0-GHz processor • One CD ROM drive • One Ethernet port • One or more PCIe slots for the HP StorageWorks 81Q PCIe Fibre Channel (FC...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 17
... information about component installation errors.) When the first component, the HP FC driver, is installed, a diagnostic window shows the HBA properties and targets found. 7. Click OK to close the SAN diagnostic window and continue the installation, or click Cancel to stop the installation. If the Simple SAN Connection Manager software component is installed on a system with EVA storage, the Add...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 18
... to the HP Storage Admin group and the Add EVA Management Account dialog box closes. The message, "Your installation is complete," is displayed. Or, if any software components fail to install, the final installation window lists those components. 9. Click the View Error Log link to open an error log that provides additional information. You may be prompted to upgrade, add, or...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 22
... will provide additional information about component installation upgrade errors.) After the FC driver is installed, a diagnostic window shows the HBA properties and targets found. 6. Click OK to close the SAN diagnostics window and continue. If you are upgrading the Simple SAN Connection Manager software component on a system with EVA storage, the Add EVA Management Account dialog box (Figure...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 24
... this procedure to upgrade the software on additional Windows servers.
Linux installation: upgrade
Follow these steps to upgrade a previous installation of the required software on servers running Linux. To upgrade the components required by Simple SAN Connection Manager on Linux: 1. Insert the installation CD into the CD-ROM drive of the server.
The installation CD should mount automatically...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 32
... the controller(s) and individual "Managing storage drives that comprise a selected subsystem. subsystems" on page 116.
Configures a new storage subsystem using a "Configuring a storage pre-defined application template or custom subsystem" on page 121. deployment.
Check for Updates
Searches the HP website for updates to HBA - drivers, switch firmware, storage subsystem firmware, and storage...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 33
...
Purpose
See
Get Network Properties Displays network information.
"Viewing network properties" on page 50.
Set Switch IP Address
Changes the switch IPv4 or IPv6 address.
"Setting the switch IP address" on page 55.
Set Switch IPsec Information
Manages a list of IP security associations and policies.
"Setting switch IP security" on page 64
Update Switch Firmware
Updates the switch with...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 120
..., each subsystem's IO traffic, and its number of drives and logical disks. 2. To continue, click Yes.
Updating storage subsystem firmware
When Simple SAN Connection Manager starts up, it compares the current storage subsystem firmware version to the firmware version available on the HP website. If it detects an available firmware update, it prompts you to download the latest update, as shown in...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 139
... of HSV virtualizing
storage controllers and the disk drives they manage.
FDMI
Fabric device management interface (FDMI) is a standard enabling the management of devices such as HBAs through the fabric.
Fibre Channel (FC) A high-speed serial interface technology that supports other higher layer protocols like SCSI and IP. Standardized under ANSI in 1994.
HBA (host bus adapter)
The board that...
HP StorageWorks Simple SAN Connection Manager user guide (5697-0083, August 2009) - Page 149
... 32, 120
updates, checking for 120 updating
components 32, 120
HBA BIOS image 76 HBA driver 78 subsystem firmware 120 switch firmware 57
user account, adding (EVA storage) 17, 22
user interface, elements of 29
V
VDS (Virtual Disk Service) 13 definition of 142
hardware providers, configuring subsystem with 125,
130 viewing
controller details 117
drive details 102, 118
drive status 118 event...
HP StorageWorks 2000 Modular Smart Array Controller Module Replacement Instructions (488318-003, April 2010) - Page 4
... install that latest version on the controllers. For more information on firmware updates, see the enclosure user guide.
Returning the failed items
In materials shipped with the replacement, HP specifies whether the failed component must be returned. Follow the provided instructions.
Additional information
HP P2000/MSA Disk Arrays: http://www.hp.com/go/msa HP storage: http://www.hp.com/storage HP...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 139
..., the Show Disk Drives page has an Address column that specifies the channel and SCSI ID of the drive as accessed through controller A and controller B.
● Select Manage > Update Software > Disk Drive Firmware > Show Disk Drive Types. The following information is displayed for each drive: ■ Vendor - Drive manufacturer. ■ Model - Drive model. ■ Firmware Revision - Revision...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 146
....
Updating Drive Enclosure Firmware
You can update drive enclosure firmware by loading a firmware update file obtained from the enclosure vendor.
Caution - Updating enclosure firmware causes all disk drives to be temporarily inaccessible. Stop all I/O to virtual disks before performing this operation.
To update drive enclosure firmware:
1. Obtain the firmware update file and store it in a network...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 182
... Mode option is enabled, after updating software on one controller you must manually upgrade the partner controller.
Caution - Do not turn off or restart the system during this process. If the code load is interrupted or there is a power failure, the unit might not be operational. If this occurs, contact technical support to attempt a serial code load recovery. In some cases the...