HP 2000i driver and firmware
Related HP 2000i Manual Pages
Download the free PDF manual for HP 2000i and other HP manuals at ManualOwl.com
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 6
... SNMP event notification in SMU 85 SNMP management 85 Enterprise trap MIB 85 FA MIB 2.2 and 4.0 Differences 87
B Event code reference 89 C Using FTP to download logs and update firmware 107
Downloading system logs 107 Updating controller module firmware 108 Updating expansion module firmware 109 Updating disk firmware 110 Installing a license file 111
Glossary 113 Index 115
6
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 13
... or medium-low. • Verify that the browser is set to allow cookies at least for the IP addresses of the storage-system
network ports.
Signing in
To sign in:
1. In the web browser's address field, type the IP address of a controller network port and press Enter. The SMU Sign In page is displayed. If the Sign In page does not...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 15
... interface. • FTP Access. Allows access to the file transfer protocol interface, which provides a way to install
firmware updates and download logs. • Base Preference. The base for entry and display of storage-space sizes. In base 2, sizes are shown as
powers of 2, using 1024 as a divisor for each magnitude. In base 10, sizes are shown as...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 30
... Transfer Protocol (FTP). A secondary interface for installing firmware updates, downloading logs, and installing a license.
• Simple Network Management Protocol (SNMP). Used for remote monitoring of the system through your network.
• Service Interface. Used for technical support only. • Service Debug. Used for technical support only.
In-band management interfaces operate through...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 33
... Transfer Protocol (FTP). A secondary interface for installing firmware updates, downloading logs,
and installing a license. • Simple Network Management Protocol (SNMP). Used for remote monitoring of the system through your
network. • Service Interface. Used for technical support only. • Service Debug. Used for technical support only. In-band management interfaces operate through...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 35
...install
firmware updates and download logs. • Base Preference. Select Base 2 to show sizes as powers of 2 (binary) using 1024 as a divisor, or
Base 10 to show sizes as powers...is 30 minutes. • Locale. The user's preferred display language, which overrides the system's default display
language. Installed language sets include Chinese-simplified, Chinese-traditional, Dutch, English, French...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 59
... with the storage system.
Updating controller module firmware
A controller enclosure can contain one or two controller modules. In a dual-controller system, both controllers should run the same firmware version. You can update the firmware in each controller module by loading a firmware file obtained from the HP web download site, http://www.hp.com/go/msa. To install an HP ROM Flash Component or...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 60
... If you updated firmware in an HP MSA70 drive enclosure, power cycle the enclosure to complete the update process.
8. Verify that the proper firmware version appears for each updated expansion module.
Updating disk firmware
You can update disk firmware by loading a firmware file obtained from HP web download site, http://www.hp.com/go/msa, or from the disk manufacturer. To install an HP ROM Flash...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 107
... target controller • Controller environment (including data about attached disks, enclosures, and so forth) It is recommended to use a command-line-based FTP client. A GUI-based FTP client might not work.
To download logs to a file
1. In SMU, prepare to use FTP: a. Determine the network-port IP addresses of the system's controllers. b. Verify that the system's FTP service is...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 108
.... If Partner Firmware Update is disabled, after updating software on one controller you must manually update the partner controller.
To update controller module firmware
1. Obtain the appropriate firmware file and download it to your computer or network. 2. In SMU, prepare to use FTP:
a. Determine the network-port IP addresses of the system's controllers. b. Verify that the system's FTP service is...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 109
... from the HP web download site, http://www.hp.com/go/msa. To install an HP ROM Flash Component or firmware Smart Component, follow the instructions on the HP web site; otherwise, to install a firmware binary file, follow the steps below.
To update expansion module firmware
1. Obtain the appropriate firmware file and download it to your computer or network. 2. In SMU, determine the address of each...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 110
... firmware
You can update disk firmware by loading a firmware file obtained from the HP web download site, http://www.hp.com/go/msa, or from the disk manufacturer. To install an HP ROM Flash Component or firmware Smart Component, follow the instructions on the HP web site; otherwise, to install a firmware binary file, follow the steps below. A dual-ported disk can be updated from either controller...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 111
6. Quit the FTP session. 7. If the updated disks must be power cycled:
a. Shut down both controllers by using SMU. b. Power cycle all enclosures as described in your product's user guide.
NOTE: If you loaded firmware to a Seagate 750-Gbyte Barracuda ES SATA drive, after spin-up it will be busy for about 50 seconds completing its upgrade. Then it will be ready...
HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-002, May 2009) - Page 116
using WBI to update expansion module 59 versions 68 firmware update, partner configuring 41 FTP downloading system logs 107 updating controller module firmware 108 updating disk drive firmware 110 updating expansion module firmware 109
G
global spare 16 global spares
adding and removing 48
H
hardware versions 68
help displaying online 15 obtaining 12 using the help window 15
host adding 56 ...
HP StorageWorks MSA2000 G2 SMI-S Proxy Provider User Guide (573100-002, December 2009) - Page 8
... Power Supply profile by adding indications. Models the profiles registered in the object manager and associations between registration classes and domain classes implementing the profile. Models software or firmware installed on the system Models device mapping and masking abilities for SCSI systems Models disk drive devices. Provides an abstraction of how it virtualizes exposable block storage...
HP StorageWorks MSA2000 G2 installation instructions (515941-002, June 2009) - Page 1
...on installing hard drives and other options, see the installation instructions provided with your option or on the Software Support/Documentation CD.
Connecting remote management hosts
The management host directly manages systems out-of-band over an Ethernet network. 1. Connect an Ethernet cable to the Ethernet management port on each
controller. 2. Connect the other end of each Ethernet cable to...
HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-002, June 2009) - Page 4
5 Basic operation 33
Powering on/powering off 33 Updating firmware 33
Selecting an appropriate time to perform the online upgrade 33
6 LED descriptions 35
Front panel LEDs 35 Disk drive LEDs 36 Rear panel LEDs 37
2312i G2 and 2324i G2 37 MSA2000 3.5" 12-drive enclosure 39 MSA70 2.5" 25-drive enclosure 39 Power supply LEDs 40
7 Configuring a system for the first...
HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-002, June 2009) - Page 13
..., newest
versions of drivers, and firmware documentation updates as well as instant access to numerous other product resources. • After signing up, you can quickly locate your products by selecting Business support and then Storage under Product Category.
HP web sites
For other product information, see the following HP web sites: • http://www.hp.com
HP StorageWorks 2000i G2 Modular...
HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-002, June 2009) - Page 31
... Software with Linux servers. To download the appropriate device mapper multi-path enablement kit for your specific enterprise Linux operating system, go to http://www.hp.com/go/devicemapper. • To prevent Microsoft Windows 2003 data hosts from displaying the Found New Hardware Wizard when the storage system is discovered, install the 2000sa G2 Modular Smart Array SCSI Enclosure Services...
HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-002, June 2009) - Page 33
... View > Overview. Expansion module A's firmware version is shown as EMP A Revision; expansion module B's firmware version is shown as EMP B Revision. For software and firmware updates, including update instructions, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support.
Selecting an appropriate time to perform the online upgrade
To ensure the success of an...