Power Supply Installation Guide - Not Orderable - Page 2

... with array power on if a third power supply is being installed to upgrade to a redundant configuration. The array will not operate with only one functional power supply; two are required. o Locate the slot where the power supply is to be installed. o Remove the filler panel or failed power supply. o Install the power supply as shown in Figure 2. o Push the power supply into the disk array...
User Guide - Page 78

2 INSTALLATION Installing the Disk Array Check the Software Install Additional SCSI-2 Host Adapter Cards on the Host Set SCSI IDs for SPs in the Disk Array(s) Connect Asynchronous (Console) Cables Connect the Power Cord Power Up the Disk Array Installation 2-1
User Guide - Page 80

Check the Software 9245XA HP-UX (A.09.04) #0: Wed Oct 26 09:44:06 PDT 1994 Note 2-3 Installation
User Guide - Page 90

... INTERFACE Built-in RS-232C mux2 lu 0 port 0 hardwired address 56 /dev/tty0p0 mux2 lu 0 port 1 hardwired address 56 /dev/tty0p1 mux2 lu 0 port 2 hardwired address 56 /dev/tty0p2 Installation mux2 lu 0 port 4 callin address 56 /dev/tty0p6 lssf /dev/ttyd0* asio0 card instance 0 hardwired at address 2/0/4/dev/tty0p0 lssf /dev/tty1* asio0 card instance 1 hardwired at address 2/0/4/dev/tty1p0 2-13
User Guide - Page 92

Note Installation Class disk disk disk disk disk disk disk LU H/W Path 22 24.0.0 23 24.0.1 24 24.0.2 25 24.0.3 12 24.1.0 26 24.1.1 27 24.1.2 Driver scsi3.target.disc3 scsi3.target.disc3 scsi3....(0x650202) S/W Status ok ok ok ok ok ok ok Class I disk 3 disk 5 H/W Path Driver S/W State 8.6.0 disc3 CLAIMED 16.3.0 disc3 CLAIMED H/W Type DEVICE DEVICE Description HP C2490AM HP C2430D 2-15
User Guide - Page 198

... Path Driver H/W Status S/W Status disk 0 8.5.0 scsi3.target.disc3 ok (0x20650202 ok disk 1 8.6.0 scsi3.target.disc3 ok (0x650202 ok disk 2 8.6.1 scsi3.target.disc3 ok (0x650202) ok OPTION PACKAGE "2" FOR HP-UX 10.0 (Two SPs in one array with jumper cable installed) Class I H/W Path Driver S/W State H/W Type Description disk 0 16.5.0 disc3 CLAIMED DEVICE DGC C2300WDR5...
User Guide - Page 210

Tool type Information Firmware Update Expert Description Provides quick access to the most useful information. Updates SP microcode and disk module firmware. Provides low-level access to the SCSI disk array for configuration and troubleshooting. Support tool license required? No Yes X X X Host Utilities and Diagnostics 7-9
User Guide - Page 220

Host Utilities and Diagnostics Menu item File Option Select File... Save As... Print... Exit... Property filename filename N/A N/A Description Specifies the microcode or firmware file to be used. Saves a file using a user-specified name. Prints a file. Exits the Firmware Update Tool. 7-19
User Guide - Page 221

...SP microcode and disk module firmware revisions currently in use (Figure 7-7). N/A N/A Download, update PROM and restart controllers Download and restart controllers Download only Reports the file previously specified using the Select File option on the File menu. Lists basic instructions for Firmware Update Tool use. Downloads microcode to the SCSI disk array's database drives, burns PROM code...
User Guide - Page 240

Tool type Information Firmware Update Expert Support tool license required? Description No Yes Provides quick access to the most useful information. X Updates SP microcode and disk module firmware. X Provides low-level access to the SCSI disk array for X configuration and troubleshooting. Host Utilities and Diagnostics 7-39
User Guide - Page 248

... As... Print... Exit... Current Revisions File Selection Property filename filename N/A N/A N/A N/A Instructions N/A Description Specifies the microcode or firmware file to be used. Saves a file using a user-specified name. Prints a file. Exits the Firmware Update Tool. Lists SP microcode and disk module firmware revisions currently in use (Figure 7-31). Reports the file previously specified...
User Guide - Page 249

Menu item Update Option Controller Firmware Disk Firmware Property Description Download, update PROM and restart controllers Downloads microcode to the SCSI disk array's database drives, burns PROM code contained in the download file into the SP's PROMs, and restarts the SP using the new microcode. Download and restart controllers Downloads microcode to the SCSI disk array's database drives...
User Guide - Page 304

... Target Addressing Mode. Drive Ready. Specified drive is powered up and physically ready for use. Format Started. The given FRU is being formatted. Format Failed. Disk module could not be physically formatted, and thus cannot be used in the disk array. Make sure the disk module is a valid model. If the model is valid, consult your HP service representative for recovery service...
User Manual - A3661-90001 - Page 133

...255.0.1 tgt CLAIMED DEVICE disk 6 8/4.8.0.255.0.1.0 sdisk CLAIMED DEVICE DGC C3400WDUNB /dev/dsk/c4t1d0 /dev/rdsk/c4t1d0 fc 1 8/8 fcT1 CLAIMED INTERFACE HP Fibre Channel Mass Storage Adapter lan 3 8/8.5 fcT1_cntl CLAIMED INTERFACE HP Fibre Channel Mass Storage Cntl /dev/fcms3 ... /dev/diag/tty0p6 /dev/tty0p6 /dev/diag/tty0p7 /dev/tty0p7 Installation Power Up the Disk Array 3-21
User Manual - A3661-90001 - Page 176

xstm Interface Table 5-2 Available Support Tools Tool type Description Support Tool license required? No Yes Information Provides quick access to the most useful information. Firmware Update Updates SP microcode and disk module firmware. Expert Provides low-level access to the disk array for configuration and troubleshooting. Information Tool 5-4 Support Tools Manager (STM)
User Manual - A3661-90001 - Page 185

... the Select File option on the File menu. Update Instructions Controller Firmware N/A Download, update PROM and restart controllers Download and restart controllers Download only Restart controllers only Lists basic instructions for Firmware Update Tool use. Downloads microcode to the disk array's database drives, burns PROM code contained in the download file to the SP's PROMs, and restarts...
User Manual - A3661-90001 - Page 212

.... Download and restart controllers Downloads microcode to the disk array's database drives and restarts the SP using the new microcode. Disk Firmware Download only Restart controllers only N/A Downloads microcode to the disk array's database drives, but does not take effect until the SPs are restarted (with a Restart Controllers only command, or by power cycling the disk array). Restarts...
User Manual - A3661-90001 - Page 214

SP Microcode Updates Disk Module Firmware Updates Caution Never reenable a peer SP while a disk module firmware update operation is in progress. Doing so can interrupt the operation, causing permanent disk module and/or data loss. Exclusive access is required to download disk firmware. All file systems should be deactivated while updating disk firmware. Expert Tool 5-42 Support Tools ...
User Manual - A3661-90001 - Page 266

... initiator (host) is performing a microcode download operation, but there are no disk drives to which the SP can appropriately install the microcode. 0x06 - Unit Attention 06/29/00 The LUN has been reset. This is reported after a power-up sequence completes or when a LUN is reset due to a SCSI Bus Reset, Bus Device Reset message or Trespass operation. The...
User Manual - A3661-90001 - Page 308

... slot or ID of the drive. The SP should be replaced. Parity error (Firmware revision greater than 9.44.00). A SCSI controller chip detected a parity error during a transfer from data RAM. (Reference the 0x00000012 code.) Parity error (Firmware revision greater than 9.44.00). A SCSI controller chip detected a parity error during a transfer from data RAM. (Reference the 0x00000012 code.) 0x00503003...
Get Help Online

Get immediate support for your HP High Availability FC Disk Array 30/FC questions from HelpOwl.com.

Recent HP High Availability FC Disk Array 30/FC-related questions:

HP Manuals

Find free HP High Availability FC Disk Array 30/FC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the HP corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.