HP Surestore 80ex - Optical Jukebox driver and firmware
Drivers and firmware downloads for this Hewlett-Packard item
Related HP Surestore 80ex Manual Pages
Download the free PDF manual for HP Surestore 80ex and other HP manuals at ManualOwl.com
Optical Drive and Library SCSI-2 Command Reference - Page 3
... a particular purpose. HewlettPackard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Revision History
New editions of this manual incorporate all material updated since the previous edition. The manual printing date and part number indicate the current edition...
Optical Drive and Library SCSI-2 Command Reference - Page 4
NOTE
Typographical Conventions
The following typographical conventions are used in this manual:
Keycap: Menu choices and screens on the jukebox. Computer Output: Information displayed in the display window and screen menu items that you can select.
Notes provide information that can be helpful in understanding the operation of the product.
iii
Optical Drive and Library SCSI-2 Command Reference - Page 5
....
SCSI-2 Jukebox Command Set: Lists all supported SCSI autochanger commands and explains each command's structure.
Drive Error Codes: Lists all error codes associated with the optical disk drive.
Autochanger Error Codes: Lists all error codes associated with the autochanger or optical disk jukebox system.
Field Replaceable Units (FRUs): Lists all the field replaceable units for optical jukeboxes...
Optical Drive and Library SCSI-2 Command Reference - Page 276
...
Drive Error Codes Internal Error Codes
Table A-3
Internal Error Codes
Error Code (hex.)
Message
0582XXXX ID Error reoccurs after retry even after changing ID Error criteria
0583XXXX DMA Update failed after Automatic Reallocation 058AXXXX DMA Update Error condition 0601XXXX Received error code NN (see Table A-5 on page A-17) from ODC
chip 0664XXXX An ODC interrupt time out 0669XXXX A disk...
Optical Drive and Library SCSI-2 Command Reference - Page 291
...-IR 5H-IR 5H-IR
Description
No additional sense information Error recovered invoked and completed (Table B-6 on page B-14) Aborted command (boot code) Autochanger becoming ready Unit must first initiate element status Fatal error - unit must be corrected manually Firmware download needed (boot code) Download checksum error Move error (Check additional sense bytes) (Table B-6 on page B-14) Invalid...
Adding 1 Drive to the C1100 Series Jukebox - C1156-90000 - Page 1
...C1100 Series Jukebox
Important! Read This First
This upgrade requires code to be downloaded to the controller PCA and the drives. BEFORE starting this upgrade, obtain the following:
* The downloadable code required for this upgrade. FTP this code from hpgrsg.gr.hp.com (15.38.89.10) using an "anonymous" login.
Further download instructions are available at that address. * A PC with a SCSI interface...
Adding 1 Drive to the C1100 Series Jukebox - C1156-90000 - Page 3
Adding 1 Drive to the C1100 Series Jukebox
ESD Precautions
The optical disk jukebox contains very sensitive electrical components. It ...disk controller and mechanism.
Tools Required
The following tools are needed for assembly/disassembly of the autochanger: • Torx driver with the following bits: T-10 , T-15, T-25 • small flatblade screwdriver
Upgrade Kit Contents
Check the upgrade...
Adding 1 Drive to the C1100 Series Jukebox - C1156-90000 - Page 5
Installing the 1-Drive Upgrade
Caution Wear a grounding strap when working inside the outer shell of this jukebox. 1. Remove the jukebox cover by removing the four T-25 screws on that hold the cover to the rear panel. 2. Slide the cover toward the rear of the unit. ...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 30
... labeling:
Your jukebox application software may label your optical disk slot locations differently. Use your application to check disk locations prior to labeling the disks.
• storage slot location (1, 2, 3, ... ) • date of format or initialization • disk owner (group, department, etc.) • storage purpose (backup, old version of operating system, etc.) HP recommends using...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 48
... CANCEL to return to READY. Information Logs
No.
Description
1
Firmware revision of the jukebox
4
Total cartridge loads for the drive.
5
Operation hours (power on time)
9
Total moves and move attempts by the disk
transport mechanism.
12 Total disk transport mechanism flips.
14 Total mailslot rotations.
16 Optical drive SCSI ID.
Additional log numbers not listed in Table 3-2 provide...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 52
... support services listed in Appendix A.
If a service call is necessary, gather the following information before calling: • model of your jukebox • serial number • brand and model of your host computer • brand and model of your host computer SCSI adapter • jukebox application software you are using and its version • any jukebox driver separate from your jukebox...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 63
...; Contact your authorized HP dealer distributor
Before calling, please record the following information and have it ready when you contact your service representative:
- model number of your jukebox - serial number - brand and model of your host computer - brand and model of your host computer SCSI adapter - jukebox application software you are using and its version - any jukebox driver you may be...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 66
... as listed below.
Before calling, please record the following information and have it ready when you contact your support center representative:
- model number of your jukebox - serial number - brand and model of your host computer - brand and model of your host computer SCSI adapter - jukebox application software you are using and its version - any jukebox driver you may be using that is separate...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 68
... service office.
Telephone Support After Warranty
Before calling, please record the following information and have it ready when you contact your support center representative:
- model number of your jukebox - serial number - brand and model of your host computer - brand and model of your host computer SCSI adapter - jukebox application software you are using and its version - any jukebox driver...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 70
... in material and workmanship when properly installed and used. If HP receives notice of such defects during the warranty period, HP will replace software media which does not execute its programming instructions due to such defects.
3. HP does not warrant that the operation of HP products will be uninterrupted or error free. If HP is unable, within a reasonable time...
HP SureStore Optical Disk Jukebox User's Guide - C1100-90015 - Page 93
... receiving of SCSI commands and controls the disk transport mechanism.
disk See optical disk.
driver A program that allows the operating system to communicate with a peripheral device.
E-L
element A SCSI term for any one of the autochanger components - drive, mailslot, storage slots, or picker.
front panel The part of the jukebox that includes a control panel used to manage and display functions...
HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version - Page 1
...support/lttfaq
Windows GUI version
This document is a brief, screenshot-based guide to help you follow instructions from HP support. For much more, and detailed information on L&TT, please see the user guide.
Where is the L&TT user guide 2 How do I install L&TT 3 How do I run L&TT 4 How do I check my drive is installed correctly 6 How do I use L&TT to find my drive serial...the Device Performance...
HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version - Page 3
...?
• L&TT is available for free download from http://www.hp.com/support/tapetools and on the CD that came with your tape drive. The download version is preferred as it is the latest version.
• Install L&TT on any server that can "see" your drive. This is most likely to be the backup server, but it could be...
HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version - Page 4
How do I run L&TT?
1. Install L&TT 2. Turn off services that may lock the tape drive such as backup software
services and Removable Storage Service (RSM) 3. Double click on the desktop icon 4. Use defaults in pop-ups 5. Wait for L&TT to scan and find your devices 6. Select the device you want to work with
HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version - Page 8
How do I verify that my drive's firmware is up to date?
You will need internet access for this. If not please refer to the user guide. 1. Install and run L&TT 2. Select the device and click Firmware on the toolbar. 3. In the Local Firmware Files tab, click Get Firmware from Web.