Dell Force10 S50P driver and firmware

Drivers and firmware downloads for this Dell item

We have a direct link to download Dell Force10 S50P drivers, firmware and other resources directly from the Dell site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

Force10 S50P driver download page on the Dell site

Related Dell Force10 S50P Manual Pages

Download the free PDF manual for Dell Force10 S50P and other Dell manuals at ManualOwl.com

FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 27

...8226; boot config • boot host • boot network • boot system • boot system gateway • cd • change bootflash-image • copycopy (Streamline Upgrade) • copy running-config startup-config • delete • dir • download alt-boot-image • download alt-full-image • download alt-system-image • format (C-Series and E-Series...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 34

... FTOS#copy scp: flash: Address or name of remote host []: 10.11.199.134 Port number of the server [22]: 99 Source file name []: test.cfg User name to login remote host: admin Password to login remote host: Destination file name [test.cfg]: test1.cfg Related Commands cd Change working directory. copy (Streamline Upgrade) c e Copy a system image to a local file and update...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 36

... to the chassis. Syntax download alt-boot-image file-url Command Modes EXEC Privilege Command History Version 7.7.1.0 Removed from E-Series and C-Series Version 7.5.1.0 Introduced on C-Series E-Series original Command Usage Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade Information command. For software upgrade details, see the FTOS Release...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 37

...of this command are incorporated into the upgrade Information command. For software upgrade details, see the FTOS Release Notes. Related Commands upgrade (E-Series version) Upgrade the bootflash or boot selector versions download alt-system-image e Download an alternate system image (not the boot flash or boot selector image) to the chassis. Syntax download alt-system-image file-url Command...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 52

... Software Force10 Operating System Version: 1.0 Force10 Application Software Version: E7-8-1-13 Copyright (c) 1999-2008 by Force10 Networks, Inc. Build Time: Mon Nov 24 18:59:27 2008 Build Path: /sites/sjc/work/sw/build/build2/Release/E7-8-1/SW/SRC Force10 uptime is 1 minute(s) System Type: S50V Control Processor: MPC8451E with 252739584 bytes of memory. 32M bytes of boot flash memory. 1 48-port...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 53

...the cached memory is released and returned for general use, but the URL is maintained and you do not have to specify it for subsequent upgrades. Related Commands upgrade fpga-image boot system Upgrade the FPGA version in the specified E-Series SFM. Display configured boot image information upgrade (C-Series version) c Upgrade the bootflash or boot selector image on a processor. Syntax upgrade...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 54

www.dell.com | support.dell.com linecard number rpm repair booted file-url Enter the keyword rpm to upgrade the system image of a selector image on all processors on the RPM. Enter this keyword to upgrade a line card newly inserted into an already upgraded chassis. This option is only available with the system-image keyword. Upgrade the bootflash or bootselector...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 56

... show sfm upgrade (E-Series version) Display the SFM status. Upgrade the E-Series. 0Usage On E-Series ExaScale, you cannot upgrade SFMs using this command when Cache Boot is configured. Information If you attempt an upgrade, you must reload the chassis to recover. Upgrading the C-Series FPGA These commands are for upgrading the FPGA for C-Series RPMs and line cards. • restore...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 60

... make a mistake, you must re-enter the parameter. Note: The IP address of the designated download port must be set before you execute this command. Otherwise, an error message will alert you that the configuration cannot proceed. See the command interface management ethernet ip address. Figure 4-1 shows the first field after you enter boot change primary. At...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 73

... cam-audit linecard clear alarms clear command history clear line configure debug cpu-traffic-stats debug ftpserver disable do enable enable xfp-power-updates end epoch exec-banner exec-timeout exit ftp-server topdir ftp-server username hostname ip ftp password send service timestamps show alarms show chassis show command-history show command-tree show...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 100

... the FTOS image on the line card. Use the power-cycle after upgrading an FPGA. When a soft reset is issued on a line card (reset linecard number), FTOS boots the line card from its runtime image. Only when you enter reset linecard number hard is the software image reloaded on the line card. Related Commands reload restore fpga...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 113

... Software Protocol Configured field on E-Series Introduced on E-Series Usage Information The show inventory media command provides some details about installed pluggable...ports in the line card, then just the header under show inventory media will be displayed. If there are fiber ports but no optics inserted, then the output will display "Media not present or accessible."C300 Example Control...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 117

...of show inventory for S-Series FTOS#show inventory System Type : S50N System Mode : 1.0 Software Version : E8-4-2-399 * 2 S50-01-GE-48T-AC DL257430183 7590005600 B CN-0RVY43-28298... configuration. Display the physical status and operational status of an installed transceiver. The output also displays the transceiver's serial number. show linecard c e Display the line card(s) status....
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 120

....dell.com | support.dell.com Table 5-1 list the definitions of the fields shown in Figure 5-28. Table 5-1. Descriptions for show linecard output Field Line card Status Next Boot Required Type Current Type Hardware Rev Num Ports Up Time FTOS Version Jumbo Capable Boot Flash Ver Memory Size Temperature Power Status Voltage Serial Number Part Num Vendor ID Date Code Description Displays...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 122

... uses the maximum 80 character length. If your display area is not set Information to 80 characters, the display will wrap. Related Commands show linecard upgrade (E-Series version) download alt-boot-image download alt-full-image download alt-system-image View the line card status Upgrade the boot flash, boot selector, or system image Download an alternate boot image to the chassis...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1435

clock update-calendar c e s Set the switch hardware clock based on the software clock. Syntax clock update-calendar Defaults Not configured. Command Modes EXEC Privilege Command History Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0 Support added for S-Series Support added for C-Series Introduced for E-Series Usage Use this command only if you are sure that the hardware clock is ...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1518

... technical support representative instructs you to do so. Layer 2 Debug Command show software macagent c This command displays tables and advanced debugging information related to the MAC Agent process. Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number Parameters configs mac-addr...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 381

.... The failover type is hot failover. FTOS displays Message 2. Message 2 FTOS Version Incompatibility Error * * Warning !!! Warning !!! Warning !!! * * * Incompatible SW Version detected !! * * This RPM -> 7.4.2.0 * Peer RPM -> 7.4.1.0 * 00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 396

... 5 is not present. Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes cache boot image downloading in progress cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area Upgrade result All cache boot image upgraded to 4.7.5.427 FTOS# View your cache boot configuration...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511

...; however, the ISO NET format is supported for addressing. To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks: • Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
Get Help Online

Get immediate support for your Dell Force10 S50P questions from HelpOwl.com.

Recent Dell Force10 S50P-related questions:

Dell Manuals

Find free Dell Force10 S50P manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Dell corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.