HP MPX200 driver and firmware
Related HP MPX200 Manual Pages
Download the free PDF manual for HP MPX200 and other HP manuals at ManualOwl.com
ISS Technology Update Volume 8, Number 5 - Page 5
... Networking Software
Current Softpaq sp43831.exe
All firmware upgrades and complete Softpaqs can be downloaded from http:www.hp.com/go/ProLiantNICs. Select ―Support and Documents‖ and enter the product name/number.
Additional resources
For additional information on the topics discussed in this article, visit these resources:
HP iSCSI resources HP network adapters
URL http:www.hp...
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 11
... Adding a host ...63 44 Virtual disk properties 64 45 Host details ...64 46 Targets tab ...65 47 Select Features page 67 48 MPIO Properties page before reboot 68 49 MPIO Properties page after reboot 68 50 Software update installation wizard 69 51 Discover targets ...71 52 Add static IP address 71 53 Discovered Targets list...
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 50
... installation presents an option for installing MPIO using the Microsoft generic DSM (Microsoft MPIO Multipathing Support for iSCSI check box). For Windows Server 2008, MPIO is installed separately as a feature.
3. See "Setting up the iSCSI initiator" on page 60 to set up the Windows host and register the IQN name.
4. Install and run the mpx Manager.
50 Managing the MPX200...
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 69
.... SNP also includes the Receive Side Scaling feature, which allows receive packet processing to scale across multiple CPUs. The HP NC3xxx Multifunction Gigabit server adapters use SNP to support TCP off-load functionality. For support details, see the latest HP adapter information at http://h18004.www1.hp.com/products/ servers/networking/index.html.
MPX200 Multifunction Router User Guide 69
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 78
...-initiator-utils during or after operating system installation. To install and configure the iSCSI driver for Red Hat 5: 1. Use the iscsiadm command to control discovery and connectivity: # iscsiadm -m discovery -t st -p 10.6.0.33:3260 2. Edit the initiator name: # vi /etc/iscsi/initiatorname.iscsi 3. Start the iSCSI service: # service iscsi start
78 MPX200 iSCSI configuration rules and guidelines
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 98
... supported in a multipath Windows configuration that is used in conjunction with Microsoft iSCSI initiator services and Microsoft MPIO. Because the iSCSI driver resides on the QLogic iSCSI HBA, it is not necessary to install the Microsoft iSCSI initiator.
Installing the QLogic iSCSI HBA
Install the QLogic iSCSI HBA hardware and software following the instructions in the QLogic installation manual...
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 161
...remove the port.
Virtual disk operation has failed. Ensure that the FC target connections are online.
Check all MPX200 FC connections to the EVA.
Cannot change iSCSI controller IP port attributes.
Enable the iSCSI controller IP port.
Command not supported with this version of the iSCSI controller.
Check the firmware version and update if necessary.
MPX200 Multifunction Router User Guide 161
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 229
... version number.
qsrSwVersion Syntax Access Description
SnmpAdminString Read-only System software (firmware) version number.
qsrNoOfFcPorts Syntax Access Description
Unsigned32 Read-only Quantity of FC ports on the system.
qsrNoOfGbEPorts Syntax Access Description
Unsigned32 Read-only Quantity of gigabit Ethernet ports on the system.
qsrAgentVersion
MPX200 Multifunction Router User Guide...
HP StorageWorks MPX200 Multifunction Router User Guide (5697-0568, August 2010) - Page 245
...Fatal Error Error Error
FC processor being restarted.`
FC processor received a SCSI command for an unknown target path or has run out of resources to execute additional commands.
FC processor was disabled by an IOCTL request to the driver.
FC processor firmware failed initialization. The request to initialize was received by the driver in an IOCTL request.
MPX200 Multifunction Router User Guide...
HP StorageWorks MPX200 Multifunction Router Data Migration Solution Guide (5697-0701, October 2010) - Page 6
... documentation ...155 Contacting HP ...155
HP technical support ...155 Subscription service ...156 Product feedback ...156 Documentation feedback 156 Related information ...156 HP Websites ...156 Typographical conventions ...157
A Configuring host multipathing software 159
Windows multipath configuration 159 HP-UX multipath configuration 161
B Simple Network Management Protocol 165
SNMP...
HP StorageWorks MPX200 Multifunction Router Data Migration Solution Guide (5697-0701, October 2010) - Page 27
...at the HP website: http://www.hp.com/go/mpx200 Table 4 Component requirements
Component Operating system
Requirement
Windows Linux: • Red Hat • SUSE Apple • Mac OS X
Memory Disk space Processor` Hardware
Internet browser
256 MB or more
150 MB per installation
500 mHz or faster
CD-ROM drive, RJ-45 Ethernet port, RS-232 serial port (optional)
Microsoft Internet Explorer 5.0 and...
QLogic Data Migration Service for iSR6200 User's Guide (ISR654608-00 C, February 2011) - Page 16
... provides the information you need to configure several types of host multipathing software on Windows®, Linux®, HP-UX, IBM® AIX, VMware® ESX, and Solaris® operating systems.
Appendix B Simple Network Management Protocol provides reference material for the simple network management protocol (SNMP), which you can use to manage the iSR6200...
QLogic iSR6200 Command Line Interface (CLI) User's Guide (ISR654601-00 D, January 2011) - Page 176
...
qsrSwVersion Syntax Access
Description
SnmpAdminString Read-only System software (firmware) version number.
qsrNoOfFcPorts Syntax Access
Description
Unsigned32 Read-only Quantity of Fibre Channel ports on the system.
qsrNoOfGbEPorts Syntax Unsigned32 Access Read-only
Description Quantity of gigabit Ethernet ports on the system.
qsrAgentVersion Syntax Access
Description
SnmpAdminString...
QLogic iSR6200 Command Line Interface (CLI) User's Guide (ISR654601-00 D, January 2011) - Page 218
...Interface (CLI) User's Guide
device A target, typically a disk drive. Hardware such as a disk drive, tape drive, printer, or keyboard that is installed in or connected to a system. In Fibre Channel, a target device.
driver The software that interfaces between the file system and a physical data storage device or network media.
electrically erasable programmable read-only memory
See EEPROM.
EEPROM...
QLogic iSR6200 Command Line Interface (CLI) User's Guide (ISR654601-00 D, January 2011) - Page 236
...85 statistics, showing for blade 2-99 storage area network, See SAN storage, iSCSI 5-1 subnet mask, port A-6 support, technical xiv switched fabric, definition of Glossary-2 syntax, command 2-4 system configuring parameters 2-53 hardware version number, showing A-19 rebooting 2-33 serial number, showing A-19 shutting down 2-106 software/firmware version number, showing
A-20
system information MIB...
QLogic iSR6200 Command Line Interface (CLI) User's Guide (ISR654601-00 D, January 2011) - Page 238
iSR6200 Command Line Interface (CLI) User's Guide
V
verifying connectivity (ping command) 2-31 version number
hardware, showing A-19 hardware/software, showing 2-101 software/firmware, showing A-20 virtual logical area network, See VLAN virtual port groups (VPGs) 4-1 definition of Glossary-8 enabling 4-3 notifications A-23 setting 2-54, 4-3 showing 2-104, 4-2 tables A-14 VLAN configuration change...
QLogic iSR6200 Router Manager User's Guide (ISR654602-00 D, February 2011) - Page 124
...qsrSwVersion Syntax Access
Description
SnmpAdminString Read-only System software (firmware) version number.
qsrNoOfFcPorts Syntax Access
Description
Unsigned32 Read-only Quantity of Fibre Channel ports on the system.
qsrNoOfGbEPorts Syntax Unsigned32 Access Read-only
Description Quantity of gigabit Ethernet (GbE) ports on the system.
qsrAgentVersion Syntax Access
Description
SnmpAdminString...
QLogic iSR6200 Router Manager User's Guide (ISR654602-00 D, February 2011) - Page 166
...programmable read-only memory
See EEPROM.
Enhanced Ethernet Also called data center Ethernet or converged enhanced Ethernet. Refers to new enhancements to the existing Ethernet standard that eliminate Ethernet's inherently lossy nature and make 10Gb Ethernet a viable storage networking transport.
Ethernet The most widely used LAN technology that transmits information between computer, typically at...
QLogic iSR6200 Router Manager User's Guide (ISR654602-00 D, February 2011) - Page 182
...1-6 Microsoft Windows 1-5 Solaris 1-6 statistics FC port, viewing 3-21 iSCSI port, viewing 3-29 status icons 2-12 storage area network, See SAN subnet mask, port A-6 switched fabric, definition of Glossary-2 symbolic name 3-7 system hardware version number, showing A-19 information objects group A-19 OID 3-16 serial number, showing A-19
system (continued) software/firmware version number, showing...
QLogic iSR6200 Router Manager User's Guide (ISR654602-00 D, February 2011) - Page 183
... password 3-17 community, setting SNMP properties A-2 configuration, SNMP A-3 receivers 3-17
U
updating firmware 1-4 upgrading firmware 1-4 user interface, component of 2-1
V
version number hardware, viewing A-19 software/firmware, showing A-20
View Logs button 2-6 View menu 2-3 viewing
help system 1-8 router information 3-1 virtual LAN, See VLAN virtual logical area network, See VLAN virtual port...