HP D2220sb Storage Blade Maintenance and Service Guide - Page 1

HP D2220sb Storage Blade Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and software. Part Number: 714240-001 February 2013 Edition: 1
HP D2220sb Storage Blade Maintenance and Service Guide - Page 2

... notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft®, Windows®, and Windows Server® are U.S. registered trademarks...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 3

... Servicing internal storage blade components 20 Avoiding equipment damage and data loss 22 Remove the access panel ...26 Install the access panel ...26 Drive blank...26 Drive...27 FBWC capacitor pack ...29 FBWC module ...30 Front panel ...31 LED panel...32 System board ...33 Drive drawer ...37 Enclosure release latch assembly ...39 Diagnostic tools ...41 HP ROM-Based Setup Utility...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 19

... some procedures: • T-10 Torx screwdriver • HP Insight Diagnostics software ("HP Insight Diagnostics" on page 41) Safety considerations Before performing service procedures, review all the safety information. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 20

... non-hot-plug operations, you must power down the D2220sb and/or the system. However, it may be necessary to leave the D2220sb powered up when performing other operations, such as hot-plug installations or troubleshooting. Storage blade preparation Servicing internal storage blade components To service any internal D2220sb component, do the following: 1. Power down the partner server blade (on...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 21

... in an orderly manner. IMPORTANT: If installing a hot-plug device, it is not necessary to power down the D2220sb. To power down the D2220sb, power down the partner server blade. See the server blade documentation. Remove the D2220sb WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 23

...: To prevent damage to electrical components, properly ground the D2220sb before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: To prevent improper cooling and thermal damage, do not operate the D2220sb or the enclosure unless all enclosure device bays and the first three storage drive bays are populated with either a component or a blank. CAUTION...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 24

... 30)." WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. Removal and replacement procedures 24
HP D2220sb Storage Blade Maintenance and Service Guide - Page 26

... component: 1. Power down the partner server blade (on page 21). 2. Remove the D2220sb (on page 21). 3. Press the access panel release button. 4. Slide the access panel toward the rear of the D2220sb. 5. Remove the access panel. Install the access panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 27

... not operate the D2220sb or the enclosure unless all enclosure device bays and the first three storage drive bays are populated with either a component or a blank. CAUTION: Thermal regulation is maintained only when the drive drawer is closed. The drive drawer open alarm is triggered under the following conditions: • A slow beep and flash (1 every 5 seconds) indicate...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 29

...drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb...Back up all data on the D2220sb. 2. Power down the partner server blade (on page 21). 3. Remove the D2220sb (on page 21). 4. ...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 30

... personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with the access panel open or removed...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 31

... access to the FBWC module. 6. Remove the cache module from the system board. The drive drawer and cable spool are not shown for clarity. IMPORTANT: To avoid possible damage to the D2220sb, be sure that the FBWC module is fully seated before installing the retaining screw. To replace the component, reverse the removal procedure. Front...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 32

... risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the D2220sb before beginning any installation procedure. Improper grounding can cause ESD. To remove the component: 1. Power down the partner server blade (on page 21...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 33

... board WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 36

... the system board. To replace the component: 1. Install the system board. 2. Install the pass-through cable in the carrier. Be sure to route the cable under the chassis support rail. 3. Install the pass-through board and cable in the drive drawer. 4. Install the capacitor cover. 5. Install the pass-through cable cover on the drive drawer. 6. Install the FBWC module. 7. Install the FBWC capacitor...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 37

... accessed locally from a laptop connected to a serial port connector on the rear of the Onboard Administrator module or remotely through a Telnet or SSH session. To enter the product information: 1. Obtain the serial number from the product information tag. 2. Access the Onboard Administrator CLI. 3. Issue the following command in the CLI: SET DEVICE SERIAL_NUMBER BLADE Drive drawer WARNING: To...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 42

... Service and Support The HP Active Health System monitors and records changes in the server hardware and system configuration. The Active Health System assists in diagnosing problems and delivering rapid resolution when server failures occur. The Active Health System collects the following types of data: • Server model • Serial number • Processor model and speed • Storage...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 43

... Management Service is available in the SPP, which is a disk image (.iso) that you can download from the HP website (http://www.hp.com/go/spp/download). The Active Health System log can be downloaded manually from iLO 4 or HP Intelligent Provisioning and sent to HP. For more information, see the HP iLO User Guide or HP Intelligent Provisioning User Guide on the HP website...
HP D2220sb Storage Blade Maintenance and Service Guide - Page 47

... storage blade shutdown. The Health status LED bar turns green when drives return to normal operating temperature. Drive LED definitions Item 1 2 3 4 LED Locate Activity ring Do not remove Drive status Status Solid blue Flashing blue Definition The drive is being identified by a host application. The drive carrier firmware is being updated or requires an update. Rotating green Drive activity...
Get Help Online

Get immediate support for your HP D2220sb questions from HelpOwl.com.

Recent HP D2220sb-related questions:

HP Manuals

Find free HP D2220sb manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the HP corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.