Dell Force10 E600i driver and firmware
Related Dell Force10 E600i Manual Pages
Download the free PDF manual for Dell Force10 E600i and other Dell manuals at ManualOwl.com
FTOS Configuration Guide FTOS 8.4.2.8 E-Series TeraScale - Page 381
.... The failover type is hot failover. FTOS displays Message 2.
Message 2 FTOS Version Incompatibility Error
*
*
Warning !!! Warning !!! Warning !!!
*
*
*
Incompatible SW Version detected !!
*
*
This RPM -> 7.4.2.0
*
Peer RPM -> 7.4.1.0
*
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different software version detected 00:00:12: %RPM0-U:CP...
FTOS Configuration Guide FTOS 8.4.2.8 E-Series TeraScale - Page 396
... 5 is not present.
Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress
cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area
Upgrade result
All cache boot image upgraded to 4.7.5.427 FTOS#
View your cache boot configuration...
FTOS Configuration Guide FTOS 8.4.2.8 E-Series TeraScale - Page 511
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
E600 TeraScale Installation Guide - Page 30
... LEDs are controlled by software which sets the threshold levels for triggering the different stages of alarms.
Line Cards
Your E600i configuration requires a minimum of one line card. Line cards are hot swappable. The line card ports provide external interface functions for connections to other systems (for example, a router or switch). Each line card has an onboard CPU for line card management...
E600 TeraScale Installation Guide - Page 32
...
Label
10/100 Ethernet
Alarms
Major
Minor ACO/LT
Description
L: Green: link is up A: Green: activity on port
Red: a critical condition exists, such as a severe over temperature condition, a fan tray failure, an over temperature condition in a power supply, or an out-of-tolerance voltage. The RPM LEDs are controlled by software which sets the threshold levels...
E600 TeraScale Installation Guide - Page 71
... (as shown below) • Service Request: Case management • Software Center: Software downloads, bug fixes, and bug tracking tool • Documents: User documentation, FAQs, field notices, technical tips, and white papers • Support Programs: Information on the suite of Dell Force10 support and professional support services. The Support Guide, available on Support Policies section of...
E600 TeraScale Installation Guide - Page 72
...to Contact Dell Force10 Log in to iSupport at http://www.force10networks.com/support/, and select the Service
TAC
Request tab.
Information to Submit When Opening a Support Case
• Your name, company name, phone number, and E-mail address • Preferred method of contact
• Model number
• Serial Number (see Requesting a Hardware Replacement)
• Software version number...
E600i System Installation Guide - Page 61
... Dell Force10 equipment and mitigating the impact of network outages. Through iSupport you can obtain technical information regarding Dell Force10 products, access to software upgrades and patches, and open and manage your Technical Assistance Center (TAC) cases. Dell Force10 iSupport provides integrated, secure access to these services. The iSupport website (http://www.force10networks.com/support...
E600i System Installation Guide - Page 62
... Your Case Downloading Software Updates Technical Documentation Contact Information
Log in to iSupport at http://www.force10networks.com/support/, and select the Service Request tab. • Your name, company name, phone number, and E-mail address • Preferred method of contact • Model number • Serial Number (see Requesting a Hardware Replacement) • Software version number...
FTOS Command Line Reference Guide FTOS 8.4.2.8 E-Series TeraScale - Page 36
... to the chassis.
Syntax download alt-boot-image file-url
Command Modes EXEC Privilege
Command History
Version 7.7.1.0
Removed from E-Series and C-Series
Version 7.5.1.0
Introduced on C-Series
E-Series original Command
Usage Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade Information command.
For software upgrade details, see the FTOS Release...
FTOS Command Line Reference Guide FTOS 8.4.2.8 E-Series TeraScale - Page 37
... FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade Information command.
For software upgrade details, see the FTOS Release Notes.
Related Commands
upgrade (E-Series version)
Upgrade the bootflash or boot selector versions
download alt-system-image
e Download an alternate system image (not the boot flash or boot selector image) to the chassis.
Syntax Command Modes...
FTOS Command Line Reference Guide FTOS 8.4.2.8 E-Series TeraScale - Page 1435
clock update-calendar
c e s Set the switch hardware clock based on the software clock.
Syntax clock update-calendar
Defaults Not configured.
Command Modes EXEC Privilege
Command History
Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.1.1.0
Support added for S-Series Support added for C-Series Introduced for E-Series
Usage Use this command only if you are sure that the hardware clock is ...
FTOS Command Line Reference Guide FTOS 8.4.2.8 E-Series TeraScale - Page 1518
... technical support representative instructs you to do so.
Layer 2 Debug Command
show software macagent
c This command displays tables and advanced debugging information related to the MAC Agent
process.
Syntax show software macagent {configs | mac-addr-table {dump | count} | port interface interface | port-channel number | stg number | vlan number} line-card number
Parameters
configs mac-addr...
FTOS Version 8.4.1.5 Configuration Guide for ExaScale - Page 373
... disruptions.
To support all the features...Card S-Series RPM S-Series Line Card
Boot Code 2.4.2.1 2.3.2.1 2.5.1.9 2.9.1.1 2.7.1.1 2.6.0.2 2.8.2.0 2.8.2.0
The features in this collection are:
• Component Redundancy • Online Insertion and Removal • Hitless Behavior • Graceful Restart • Software Resiliency • Warm Upgrade • Hot-lock Behavior • In-Service...
FTOS Version 8.4.1.5 Configuration Guide for ExaScale - Page 388
... auto upgrade feature is not supported with cacheboot. If you attempt an SFM auto upgrade, you must reload the chassis to recover.
The Dell Force10 system has the ability to boot the chassis using a cached FTOS image. FTOS stores the system image on the bootflash for each processor so that:
• the processors do not have to download the...
FTOS Version 8.4.1.5 Configuration Guide for ExaScale - Page 390
... 2 is not present.
linecard 3 is not present.
linecard 4 invalid
6.5.1.8
linecard 5 is not present.
Note: [b] : booted [n] : next boot Upgrade cache boot image(4.7.5.427) for all cards [yes/no]: yes
cache boot image downloading in progress
cache boot upgrade in progress. Please do NOT power off the card. Note: Updating Flash Table of Contents... Erasing TOC area
390 | High Availability
FTOS Version 8.4.1.5 Configuration Guide for ExaScale - Page 502
...; however, the ISO NET format is supported for addressing.
To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks:
• Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB • Accept external...
FTOS Version 8.4.1.5 Configuration Guide for ExaScale - Page 1125
... and can be saved to a file either manually or automatically upon failover.
• There are two trace files for CP: software and command-history. • There is one trace file for LP: software.
Automatic trace log updates
The system automatically saves software trace files to the internal flash. The files are saved to the TRACE_LOG_DIR directory...
Quick Start Guide - Page 5
..., refer to the following documents:
Documentation Hardware installation and power-up instructions
Software configuration
Command line interface
Latest updates
E300
E600i
E1200i
Installing and Maintaining the E300 System
E600i System Installation Guide
E600i TeraScale Installation Guide
E1200i ExaScale Installation Guide
Installing and Maintaining the E1200i System
FTOS Configuration FTOS...
Quick Start Guide - Page 40
... Assignments Between the E-Series Console and a DTE Terminal Server
Console Port RJ-45 to RJ-45 Rollover Cable RJ-45 to DB-9 Terminal Adapter Server Device
Signal
RJ-45 Pinout RJ-45 Pinout DB-9 Pin
Signal
RTS
1
8
8
CTS
DTR
2
7
6
DSR
TxD
3
6
2
RxD
GND
4
5
5
GND
GND
5
4
5
GND
RxD
6
3
3
TxD
DSR
7
2
4
DTR
CTS
8
1
7
RTS
38