Service Guide - Page 3

...are shipped with the board or that may be required to update the system. This includes information for navigating through the BIOS Setup screens, performing a BIOS update, and resetting the password or BIOS defaults. The back of this manual provides technical specifications, regulatory information, "getting help" information, and the warranty. Intel® Server System SR1600UR Service Guide iii
Service Guide - Page 9

... 5 Server System Feature Overview 6 Server System Components 9 Intel® Light-Guided Diagnostics 10 Server Board Components 14 Configuration Jumpers 16 Front of Server System ...17 Peripheral Devices ...17 Control Panel ...19 Bezels ...22 Rear of Server System ...22 Back Panel Connectors 23 SAS/SATA Backplanes ...24 Active Backplane ...24 Passive Backplane ...25 RAID Support ...26...
Service Guide - Page 11

...97 Entering BIOS Setup 97 If You Cannot Access Setup 97 Setup Menus ...97 Upgrading the BIOS ...99 Preparing for the Upgrade 99 Upgrading the BIOS 100 Clearing the Password ...100 Restoring the BIOS Defaults 102 Appendix A: Technical Reference 103 600-W Single Power Supply Input Voltages 103 600-W Single Power Supply Output Voltages 104 Intel® Server System SR1600UR Service Guide xi
Service Guide - Page 20

...swap hard drive system) ships with the following items: • Intel® Server Board S5520UR, installed in the server system • One 600-W power supply, installed in the server system • Full-length and full-height PCI Express* riser card assembly, installed in the server system • Standard control panel module and cables (I/O and USB), installed in the erver system • Three...
Service Guide - Page 21

... drawings and LED information For basic BIOS settings and chipset information If you just received this product and you need to assemble your system and install components Intel® Server System SR1600UR Technical Product Specification Available at: http://www.intel.com/p/en_US/support/highlights/server/s5520ur Intel® Server Board S5520UR Technical Product Specification Available at...
Service Guide - Page 22

... Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product Processors that have been tested with this product DIMMs that have been tested with this product Hard Drives that have been tested with this product Server Configurator Tool Available at: http://serverconfigurator.intel.com/default.aspx Latest drivers, firmware updates (BIOS, BMC, FRUSDR...
Service Guide - Page 36

...The Intel® Server System SR1600UR does not support all SAS or Serial ATA (SATA) hard drives. For a list of supported hard drives, use the Server Configurator Tool. For a web link to this tool, see "Additional Information and Software" on page 3. Slimline Optical Drive Carrier The system includes a slimline optical drive carrier, which can be used to install an optional SATA optical drive. The...
Service Guide - Page 38

... the Intel® Local Control Panel. Note: The Intel® Local Control Panel is only supported in the hot-swap hard drive system (Product Code: SR1600URHS). For instructions on installing the standard control panel, see "Replacing the Control Panel Module (Hot-swap Hard Drive System only)" on page 88. A B C D E F O N ML KJ I H G TP02099 20 Intel® Server System SR1600UR Service Guide
Service Guide - Page 44

... Support The server system provides an embedded SATA controller on the server board that is accessible through the passive backplane. The SATA controller supports both 1.5 and 3.0 Gbps data transfer rates. The BIOS Setup utility provides multiple drive configuration options on the Advanced | ATA Controller setup page, some of which affect the ability to configure RAID. The Onboard SATA Controller...
Service Guide - Page 47

3 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the "Safety Information" on page v at the beginning of this manual. Note: Whenever you service the system, you must first power down the server and unplug all peripheral devices and the AC power cord. Tools and Supplies Needed • Phillips* (cross head) screwdrivers (#1 bit...
Service Guide - Page 67

.... Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to remove the cover could result in damage to the system. Installing the Processor To install a processor, follow these instructions: 1. Remove the PCI riser assembly. For instructions, see "Removing the PCI Riser Assembly" on page 41. Intel® Server System SR1600UR Service Guide 49
Service Guide - Page 75

... of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. You can install up to three fixed SATA hard drives in the Intel® Server System SR1600UR (Product Code: SR1600UR). Note: For a web link to a list of supported hardware, see "Additional Information and Software" on...
Service Guide - Page 79

... in Figure 50). B A AF002943 Figure 50. Removing Hot-swap Disk Carrier from the Server System 3. Remove the four screws that attach the plastic retention device or the previously installed hard drive to the drive carrier (see letter "A" in Figure 51). Remove the plastic retention device (see letter "B" in Figure 51) and store it for future use. Intel® Server System SR1600UR Service Guide 61
Service Guide - Page 81

... proper system cooling, a filler blank must be installed if you do not install a device at this location. Note: A USB Floppy drive is not supported in the Intel® Server System SR1600UR with fixed mount hard drives (Product Code: SR1600UR). For a web link to a list of supported hardware, see "Additional Information and Software" on page 3. Intel® Server System SR1600UR Service Guide 63
Service Guide - Page 115

... a value cannot be changed for any reason, the feature's value field is inaccessible. The following table describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Use Key to Press Description Pressing on any menu invokes the general help window. Intel® Server System SR1600UR Service Guide 97
Service Guide - Page 117

...to be followed to return the system to service. See "Additional Information and Software" on page 3 for a web link to necessary software and instructions. Recording the Current BIOS Settings 1. Boot the computer and press when you see the message: Press Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Intel® Server System SR1600UR Service Guide 99
Service Guide - Page 118

... the upgrade. Caution: Do not power down the system during the BIOS update process! The system will reset automatically when the BIOS update process is completed. Note: You may encounter a CMOS Checksum error or other problem after reboot. If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, load BIOS defaults, check your settings, save...
Service Guide - Page 127

...-in adapters (Example: NICs, Management Adapters, Serial Expansion Cards, PCI-Express* Adapters, RAID Controllers, SCSI Controllers, etc.): Type Slot Manufacturer Model Firmware Third party hardware (Example: Example: KVM, Chassis, etc): Description/Use Manufacturer Model Firmware Storage Devices (Example: SCSI, SATA, SAS, USB, Tape, etc.): Manufacturer Model Type Size Firmware In...
Service Guide - Page 128

... version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number Detailed description of issue: Troubleshooting tried: 110 Intel® Server System SR1600UR Service Guide
Service Guide - Page 139

...boards, server chassis, server RAID controller cards, and Intel® Server Management at http://www.intel.com/reseller/. Note: You will need to log in to the Reseller site to obtain the 24x7 number. Warranty Information To obtain warranty information, visit the following Intel web site: http://www.intel.com/support/motherboards/server/sb/CS-010807.htm. Intel® Server System SR1600UR Service...
Get Help Online

Get immediate support for your Intel SR1600UR questions from HelpOwl.com.

Recent Intel SR1600UR-related questions:

Intel Manuals

Find free Intel SR1600UR - Server System - 0 MB RAM manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.